Journals / Turkish Journal of Chemistry / 2020 / Cilt: 44 - Sayı: 4

Voltammetric determination of itopride using carbon paste electrode modified with Gd doped TiO2 nanotubes

Pages
1122–1133
Publication Date
2020-08-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Cyclic voltammetry analysis showed high correlation coefficient of 0.9973 for itopride (0.04-0.2 mg/mL) with a limit of detection (LOD) and limit of quantitation values (LOQ) of 2.9 and 23.0 mu g.mL(-1) respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In the present work TiO2 nanotubes (TNT) have been synthesized by alkaline hydrothermal transformation.
📊
Key Findings & Data:Comparison of bare carbon paste electrode and Gd doped and undoped TNT carbon paste electrode for 1.0 x10(-3) M K-4 [Fe(CN)(6)] voltammetric analysis; it was observed that Gd doped TNT modified electrode has advantage of high sensitivity.
💡
Conclusion & Impact:Cyclic voltammetry analysis showed high correlation coefficient of 0.9973 for itopride (0.04-0.2 mg/mL) with a limit of detection (LOD) and limit of quantitation values (LOQ) of 2.9 and 23.0 mu g.mL(-1) respectively.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Gd-TiO2 nanotube · hydrothermal · cyclic voltammetry

Abstract

In the present work TiO2 nanotubes (TNT) have been synthesized by alkaline hydrothermal transformation. Then they have been doped with Gd element. Characterizations of doped and undoped TNT have been done with TEM and SEM. The chemical composition was analyzed by EDX, Raman and FTIR spectroscopy. The crystal structure was characterized by XRD. Carbon paste electrode has been fabricated and mixed with Gd doped and undoped TNT to form a nanocomposite working electrode. Comparison of bare carbon paste electrode and Gd doped and undoped TNT carbon paste electrode for 1.0 x10(-3) M K-4 [Fe(CN)(6)] voltammetric analysis; it was observed that Gd doped TNT modified electrode has advantage of high sensitivity. Gd doped TNT modified electrode has been used as working electrode for itopride assay in a pharmaceutical formulation. Cyclic voltammetry analysis showed high correlation coefficient of 0.9973 for itopride (0.04-0.2 mg/mL) with a limit of detection (LOD) and limit of quantitation values (LOQ) of 2.9 and 23.0 mu g.mL(-1) respectively.

🔖

Cite This Article

AMRO, A. N., EMRAN, K., ALANAZİ, H. (2020). Voltammetric determination of itopride using carbon paste electrode modified with Gd doped TiO2 nanotubes. Turkish Journal of Chemistry, Cilt: 44 - Sayı: 4, 1122–1133. https://ajindex.com/articles/214932

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. Ali I, 2018,
  2. CHEMOSPHERE, V207, P285, DOI 10.1016/j.chemosphere.2018.05.075 Amro AN, 2020, CURR PHARM ANAL, V16, P312, DOI 10.2174/1573412915666190912122421 Bard A.J., 2001, ELECTROCHEMICAL METH. Bavykin DV, 2006, ADV MATER, V18, P2807, DOI 10.1002/adma.200502696 Beydoun D, 1999, J NANOPART RES, V1, P439, DOI 10.1023/A:1010044830871 Clarizia L., 2018, MULTIFUNCTIONAL PHOT, V9, P187 Emran KM, 2020, J ELECTROANAL CHEM, V856, DOI 10.1016/j.jelechem.2019.113661 Emran KM., 2020, FABRICATION CHARACTE. Fadr M, 2018, TROP J PHARM RES, V17, P1847, DOI 10.4314/tjpr.v17i9.24 Gupta KR, 2010, E-J CHEM, V7, pS49, DOI 10.1155/2010/526891 Gupta KR, 2010,
  3. ORBITAL, V2, P209. Gupta VK, 2011, ANAL BIOCHEM, V408, P179, DOI 10.1016/j.ab.2010.09.027 Huang S, 2016, SENSOR ACTUAT B-CHEM, V234, P264, DOI 10.1016/j.snb.2016.04.167 Hun X, 2008, SENSOR ACTUAT B-CHEM, V131, P403, DOI 10.1016/j.snb.2007.11.055 Ianesko F, 2018,
  4. ELECTROANAL, V30, P1946, DOI 10.1002/elan.201800074 Katagiri F, 2006,
  5. PHARMACOLOGY, V77, P115, DOI 10.1159/000093485 Khalifa A, 2018, J ELECTROCHEM SOC, V165, pH128, DOI 10.1149/2.0491803jes Khan A, 2016, J PHARMACEUT BIOMED, V121, P6, DOI 10.1016/j.jpba.2015.12.036 Kim YS, 2005, WORLD J GASTROENTERO, V11, P4210 Lee HW, 2007, ANAL CHIM ACTA, V583, P118, DOI 10.1016/j.aca.2006.09.061 Li BL, 2020,
  6. COMMUN MATH BIOL NEU, DOI 10.28919/cmbn/4262 Li ZX, 2011, CHEM COMMUN, V47, P8109, DOI 10.1039/c1cc12539g Ma J, 2009, PHARMACOL RES, V59, P189, DOI 10.1016/j.phrs.2008.11.007 Nie JL, 2013, ELECTROCHIM ACTA, V90, P589, DOI 10.1016/j.electacta.2012.12.049 Parnicka P, 2019, RESULTS PHYS, V12, P412, DOI 10.1016/j.rinp.2018.11.073 Pillai S, 2008, INDIAN J PHARM SCI, V70. Pourghobadi R, 2018, IRAN CHEM COMMUN, V6, P359 Ragab MT, 2015,
  7. TALANTA, V138, P28, DOI 10.1016/j.talanta.2015.01.045 Rajan VST, 2010, J YOUNG PHARM, V2, P410, DOI 10.4103/0975-1483.71634 Ramadan NK, 2015, SPECTROCHIM ACTA A, V137, P463, DOI 10.1016/j.saa.2014.09.003 Rasheed SH, 2011, E-J CHEM, V8, P37, DOI 10.1155/2011/683845 Reszczynska J, 2014, APPL SURF SCI, V307, P333, DOI 10.1016/j.apsusc.2014.03.199 Roy P, 2011, ANGEW CHEM INT EDIT, V50, P2904, DOI 10.1002/anie.201001374 Sabnis SS, 2008, SPECTROCHIM ACTA A, V69, P849, DOI 10.1016/j.saa.2007.05.048 Siddiqui MR, 2017, ARAB J CHEM, V10, pS1409, DOI 10.1016/j.arabjc.2013.04.016 Suganthi A, 2008, INDIAN J PHARM SCI, V70, P366, DOI 10.4103/0250-474X.43004 Sun YH, 2009, ANAL CHIM ACTA, V648, P174, DOI 10.1016/j.aca.2009.07.003 Turki A, 2013, APPL CATAL B-EN