Journals / Journal of Construction Engineering, Management & Innovation (Online) / 2020 / Cilt: 3 - Sayı: 4

Assessing the indoor comfort conditions through energy performance and CFD analyses for a traditional masonry chimney

Pages
264–274
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed that the influence of the Russian stove's unique specifications enabled acquiring the better level of desired indoor comfort conditions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Energy performance and heat flux of a traditional heating system, called Russian masonry stove, was analyzed with a comparative study based on its original S-shaped chimney design and high specific heat value firestone material.
📊
Key Findings & Data:The study aims to improve building energy performance by taking advantage of traditional techniques.
💡
Conclusion & Impact:The results showed that the influence of the Russian stove's unique specifications enabled acquiring the better level of desired indoor comfort conditions.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Energy performance and heat flux of a traditional heating system, called Russian masonry stove, was analyzed with a comparative study based on its original S-shaped chimney design and high specific heat value firestone material. The study aims to improve building energy performance by taking advantage of traditional techniques. The paper was structured within three stages; architectural modeling of the stove, to identify and understand the architecture of the system, energy performance modeling of the stove, to specify the system performance and CFD modeling of the stove, to analyze the system's performance influence on indoor comfort conditions. Results were compared with the steel casting straight chimney stove which is commonly used in contemporary architecture. The results showed that the influence of the Russian stove's unique specifications enabled acquiring the better level of desired indoor comfort conditions. The installation of the Russian stove to the contemporary buildings would be suggested in respect of providing the level of thermal comfort and energy performance.

🔖

Cite This Article

KIRANT, H. T., SÖZER, H. (2020). Assessing the indoor comfort conditions through energy performance and CFD analyses for a traditional masonry chimney. Journal of Construction Engineering, Management & Innovation (Online), Cilt: 3 - Sayı: 4, 264–274. https://ajindex.com/articles/214337

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (19)

  1. European Energy Agency. Final energy consumption by sector and fuel., 2015. doi:CSI 027/ENER 016
  2. Eurostat, Manual for statistics on energy consumption in households. 2013. [3] http://sites.google.com/site/ae390assign5/stove. Acessed at March 2019
  3. Matesz K. Masonry Heaters, Chelsea Green Publishing, Vermont, 2018
  4. Skreiberg Ø, Georges L (2017) Wood stove material configurations for increased thermal comfort. Energy Procedia, 142: 488–494
  5. Georges L, Skreiberg Ø, Novakovic V (2014) On the proper integration of wood stoves in passive houses under cold climates. Energy and Buildings, 72: 87–95
  6. Tabet F, Fichet V, Plion P (2016) A comprehensive CFD based model for domestic biomass heating systems. Journal of the Energy Institute, 89(2): 199–214
  7. Varunkumar S, Rajan NKS, Mukunda HS (2012) Experimental and computational studies on a gasifier-based stove. Energy Conversion and Management, 53(1): 135–141
  8. Athanasios N, Nikolaos N, Nikolaos M, Panagiotis G, Kakaras E (2015) Optimization of a log wood boiler through CFD simulation methods. Fuel Processing Technology, 137: 75–92
  9. Prapas J, Baumgardner ME, Marchese AJ, Willson B, DeFoort M (2014) Influence of chimneys on combustion characteristics of buoyantly driven biomass stoves. Energy for Sustainable Development, 23: 286–293
  10. Carvalho RL, Vicente ED, Tarelho LAC, Jensen OM (2018) Wood stove combustion air retrofits: A low-cost way to increase energy savings in dwellings. Energy and Buildings, 164: 140–152
  11. Hanley PM, Saez D, Nielson C, Warneck H Efficiency Study of a Contraflow Masonry Wood- Burning Heater, 2005
  12. Autodesk Help, Turbulence, Autodesk Knowledge Network, 2018
  13. Samuelsson H. CFD Modeling and Design of an Air Heater Mixing System in a Gypsum Board Dryer, Linköping University, 2015
  14. ANSI/ASHRAE Standard 55. Thermal Environmental Conditions for Human Occupancy, Atlanta, GA, 2010
  15. Fanger PO. Thermal comfort. Analysis and applications in environmental engineering. New York: McGraw-Hill, 1970
  16. Turkish Standards Institution. TS825 Thermal insulation requirements for buildings, 2014
  17. Cardarelli F. Materials Handbook. London: Springer London, 2008
  18. Autodesk Support, How do I know that I have a good mesh? (CFD), Autodesk Knowledge Network, 2016
  19. Stout RP, Billings D. Accuracy and Time Resolution in Thermal Transient Finite Element Analysis, 2002.