Journals / Atmospheric Pollution Research / 2017 / Cilt: 8 - Sayı: 5

Assessment of ammonia and greenhouse gas emissions from broiler houses in Portugal

Pages
949–955
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results showed that the maximum concentrations of NH3, N2O, CO2 and CH4 did not exceed the threshold values recommended to maintain indoor air quality on broiler houses.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Broiler husbandry is a significant source of ammonia (NH3), nitrous oxide (N2O), carbon dioxide (CO2) and methane (CH4) emissions but scarce studies have been made under Mediterranean conditions.
📊
Key Findings & Data:The aim of this study was to evaluate the NH3, N2O, CO2 and CH4 emissions on commercial broiler houses under Portuguese winter conditions.
💡
Conclusion & Impact:Results showed that the maximum concentrations of NH3, N2O, CO2 and CH4 did not exceed the threshold values recommended to maintain indoor air quality on broiler houses.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Broiler husbandry is a significant source of ammonia (NH3), nitrous oxide (N2O), carbon dioxide (CO2) and methane (CH4) emissions but scarce studies have been made under Mediterranean conditions. The aim of this study was to evaluate the NH3, N2O, CO2 and CH4 emissions on commercial broiler houses under Portuguese winter conditions. The study was made on a commercial broiler farm located in central Portugal. Three tunnel ventilated broiler houses with similar equipment and production practices were selected. The outdoor and indoor environmental conditions, gas concentrations and ventilation rates of each broiler house were measured during 42 days of growing cycle. Results showed that the maximum concentrations of NH3, N2O, CO2 and CH4 did not exceed the threshold values recommended to maintain indoor air quality on broiler houses. The average emission rates from broiler houses under winter 1 1 conditions were 0.13 ± 0.04, 0.041 ± 0.002, 96.2 ± 8.8 and 0.226 ± 0.013 g day bird (22.0 ± 7.3, 6.7 ± 0.3, 16,028 ± 1465 and 37.7 ± 2.1 g day 1 LU 1) for NH3, N2O, CO2 and CH4, respectively. Furthermore, NH3 and N2O emission rates of this study are in the same range than measurements from most European countries, but CH4 emission rate seems higher to those reported for Mediterranean countries.

🔖

Cite This Article

Pereira, J. L. (2017). Assessment of ammonia and greenhouse gas emissions from broiler houses in Portugal. Atmospheric Pollution Research, Cilt: 8 - Sayı: 5, 949–955. https://ajindex.com/articles/214270

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Xu, W., Zheng, K., Liu, X., Meng, L., Huaitalla, R.M., Shen, J., Hartung, E., Gallmann, E., Roelcke, M., Zhang, F., 2014. Atmospheric NH3 dynamics at a typical pig farm in China and their implications. Atmos. Pollut. Res. 5, 455e463. Wiedemann, S.G., Phillips, F.A., Naylor, T.A., McGahan, E.J., Keane, O.B., Warren, B.R., Murphy, C.M., 2016. Nitrous oxide, ammonia and methane from Australian meat chicken houses measured under commercial operating conditions and with mitigation strategies applied. Anim. Prod. Sci. 56, 1404e1417. Wheeler, E.F., Casey, K.D., Gates, R.S., Xin, H., Zajaczkowski, J.L., Topper, P.A., Liang, Y., Pescatore, A.J., 2008. Ammonia emissions from twelve U.S. broiler chicken houses. Trans. ASABE 49, 1495e1512. Van der Heyden, C., Demeyer, C., Volcke, E.I.P., 2015. Mitigating emissions from pig and poultry housing facilities through air scrubbers and biofilters: state-of-the- art and perspectives. Biosyst. Eng. 134, 74e93. Sommer, S.G., Zhang, G.Q., Bannink, A., Chadwick, D., Misselbrook, T., Harrison, R., Hutchings, N.J., Menzi, H., Monteny, G.J., Ni, J.Q., Oenema, O., Webb, J., 2006. Algorithms determining ammonia emission from buildings housing cattle and pigs and from manure stores. Adv. Agron. 89, 261e335. Seedorf, J., Hartung, J., Schroder,€ M., Linkert, K.H., Pedersen, S., Takai, H., Johnsen, J.O., Metz, J.H.M., Groot Koerkamp, P.W.G., Uenk, G.H., Phillips, V.R., Holden, M.R., Sneath, R.W., Short, J.L., White, R.P., Wathes, C.M., 1998. A survey of ventilation rates in livestock buildings in Northern Europe. J. Agric. Eng. Res. 70, 39e47. Rotz, C.A., 2004. Management to reduce nitrogen losses in animal production. J. Anim. Sci. 82, E119eE137. Roumeliotis, T.S., Dixon, B.J., Van Heyst, B.J., 2010. Characterization of gaseous pollutant and particulate matter emission rates from a commercial broiler operation. Part I: observed trends in emissions. Atmos. Environ. 44, 3770e3777. REAP, 2013. Decree number 81/2013 of 14 June regarding animal manure man- agement (REAP). In: Diario da República, Serie I, number 113 of 14 June 2013. Portugal, pp. 3304e3329. PIIR, 2017. Portuguese Informative Inventory Report 1990-2015. Submitted under the NEC Directive (EU) 2016/2284 and the UNECE Convention on Long-range Transboundary Air Pollution. Portuguese Informative Inventory Report (PIIR). Portuguese Environmental Agency, Lisbon, Portugal, p. 449. Pereira, J., Misselbrook, T.H., Chadwick, D.R., Coutinho, J., Trindade, H., 2012. Effects of temperature