AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The central coast region had the major impact at this site (with 50% and 67% of back trajectory crossing reported overall and summer, respectively).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Measurements of total PM 2.5 from February 1998 to February 2017 were undertaken at Richmond, Australia and elemental composition was determined using Ion Beam Analysis.
📊
Key Findings & Data:Using positive matrix factorisation seven source fingerprints were identified; soil dust Soil (4.1% ± 0.6%), industrial sulfur with aged sea spray IndSaged (16% ± 1%), fresh sea salt Sea (4.8% ± 0.7%), secondary sulfate 2ndryS (24% ± 1%), Smoke (31% ± 1%), industrial metals Indmetals (1.9% ± 0.9%) and vehicle emissions Auto (18% ± 1%).
💡
Conclusion & Impact:The central coast region had the major impact at this site (with 50% and 67% of back trajectory crossing reported overall and summer, respectively).
🔬Design:Research Article
📍Scope:2017 Verileri
⚙️Variables:Domain Parameters

Özet

Measurements of total PM 2.5 from February 1998 to February 2017 were undertaken at Richmond, Australia and elemental composition was determined using Ion Beam Analysis. Using positive matrix factorisation seven source fingerprints were identified; soil dust Soil (4.1% ± 0.6%), industrial sulfur with aged sea spray IndSaged (16% ± 1%), fresh sea salt Sea (4.8% ± 0.7%), secondary sulfate 2ndryS (24% ± 1%), Smoke (31% ± 1%), industrial metals Indmetals (1.9% ± 0.9%) and vehicle emissions Auto (18% ± 1%). Back trajectory analysis showed that 27% of the measurements recorded at least one crossing with a coal-fired power station. During the study period a reduction in the SO 2 emissions was seen and three coal-fired power stations were closed; one each to the north, west and north-east (central coast) of the sampling site. The central coast region had the major impact at this site (with 50% and 67% of back trajectory crossing reported overall and summer, respectively). One of the central coast coal-fired power stations, Munmorah, closed in July 2012, followed by the closure of a western power station Wallerawang and a northern power station Redbank in the second half of 2014. When the difference in the average of the four years before the closure of Munmorah was compared against the average of the four years after the closure, a 32% reduction in the mean of secondary sulfate fingerprint was observed (from 1.47 μg/m 3 to 1.00 μg/m 3 ) and about 27% was attributed to the reduction in emissions from the coal-fired power stations and 5% due to the reduction in releases from other sources.

🔖

Cite This Article

CRAWFORD, J., COHEN, D. D., ATANACİO, A. (2018). The impact of closure of coal-fired power stations on aerosol concentrations in the Sydney Basin. Atmospheric Pollution Research, Cilt: 9 - Sayı: 6, 1167–1176. https://ajindex.com/articles/214263

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Amann, M., Klimont, Z., Wagner, F., 2013. Regional and global emissions of air pollu- tants: recent trends and future scenarios. Annu. Rev. Environ. Resour. 38, 31–55. http://www.annualreviews.org/doi/pdf/10.1146/annurev-environ-052912-173303.
  2. Amato, F., Hopke, P.K., 2012. Source apportionment of the ambient PM2.5 across St. Louis using constrained positive matrix factorisation. Atmos. Environ. 46, 329–337.
  3. Anthes, R.A., 1978. The height of the planetary boundary layer and the production of circulation in a sea breeze model. J. Atmos. Sci. 35, 1231–1239.
  4. Arrowsmith, A., Hedley, A.B., 1975. By atmospheric reactions. The formation of ammo- nium sulphate particles. Rev. Port. Quim. 17, 168–173.
  5. Ayers, G.P., Keywood, M.D., Gras, J.L., Cohen, D., Garton, D., Bailey, G.M., 1999. Chemical and Physical Properties of Australian Fine Particles: a Pilot Study. Final Report to Environment Australia 97pp. Barrett, E.G., Day, K.C., Gigliotti, A.P., Reed, M.D., McDonald, J.D., Mauderly, J.L., Seilkop, S.K., 2011. Effects of simulated downwind coal combustion emissions on pre- existing allergic airway responses in mice. Inhal. Toxicol. 23 (13), 792–804. http:// dx.doi.org/10.3109/08958378.2011.609917. Beaver, S., Palazoglu, A., Singh, A., Soong, S.-T., Tanrikulu, S., 2010. Identification of weather patterns impacting 24-h average fine particulate matter pollution. Atmos. Environ. 44, 1761–1771.
  6. Cohen, D.D., Bailey, G.M., Kondepudi, R., 1996. Elemental analysis by PIXE and other IBA techniques and their application to source fingerprinting of atmospheric fine particle pollution. Nucl. Instrum. Methods 109, 218–226.
  7. Cohen, D.D., Crawford, J., Stelcer, E., Bac, V.T., 2010. Characterisation and source ap- portionment of fine particulate sources at Hanoi from 2001 to 2008. Atmos. Environ. 44, 320–328.
  8. Cohen, D.D., Crawford, J., Stelcer, E., Atanacio, A.J., 2012. Application of positive matrix factorization, multi-linear engine and back trajectory techniques to the quantification of coal-fired power station pollution in metropolitan Sydney. Atmos. Environ. 61, 204–211.
  9. Crawford, J., Chambers, S., Cohen, D., Williams, A., Griffiths, A., Stelcer, E., 2016a. Assessing the impact of atmospheric stability on locally and remotely sourced aero- sols at Richmond, Australia, using Radon-222. Atmos. Environ. 127, 107–117.
  10. Crawford, J., Griffiths, A., Cohen, D.D., Jiang, N., Stelcer, E., 2016b. Particulate pollution in the Sydney region: source diagnostics and synoptic controls. Aerosol A