Journals / Diagnostic and Interventional Radiology / 2015 / Cilt: 21 - Sayı: 6

Geometrical characteristics after Y-stenting of the basilar bifurcation

Pages
483–487
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Most of the an-gular remodeling occurs on the side that had a more acute angle before stent deployment.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:PURPOSE We aimed to investigate the angular changes after Y-stenting of the basilar bifurcation aneurysms.METHODS A total of 19 patients (age range, 27-80 years; mean age, 52.5 years) underwent Y-stent coiling for basilar bifurcation aneurysm.
📊
Key Findings & Data:Three vascular angles (?, ?1, ?2) were measured in the anteroposterior plane. ?1 and ?2 represented the angles between the basilar artery and the proximal P1 segments of the right and left posterior cerebral arteries, respectively. ? represented the complementary angle between the ?1 and ?2 angles.
💡
Conclusion & Impact:Most of the an-gular remodeling occurs on the side that had a more acute angle before stent deployment.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

PURPOSE We aimed to investigate the angular changes after Y-stenting of the basilar bifurcation aneurysms.METHODS A total of 19 patients (age range, 27-80 years; mean age, 52.5 years) underwent Y-stent coiling for basilar bifurcation aneurysm. Three vascular angles (?, ?1, ?2) were measured in the anteroposterior plane. ?1 and ?2 represented the angles between the basilar artery and the proximal P1 segments of the right and left posterior cerebral arteries, respectively. ? represented the complementary angle between the ?1 and ?2 angles. Angles were measured before and after stent deployment. Diameters of the basilar artery and P2 segment of the posterior cerebral artery were measured at both sides. Correlation between vascular diameter and angular change of the basilar bifurcation was investi-gated.RESULTS Statistically significant ?, ?1, and ?2 angle changes were found after stent deployment (P < 0.001). There was no statistically significant relationship between the diameter of the basilar artery and the ?, ?1, ?2 angle changes (P > 0.05). There was no statistically significant relationship between the diameter of the posterior cerebral artery and the ? angle change (P > 0.05). We found a statistically significant inverse correlation between pre-stent ? angle and post-stent angle change (right side, P = 0.008; left side, P < 0.001).CONCLUSION Y-stenting narrows the effective neck and straightens the vascular bifurcation angle. Most of the an-gular remodeling occurs on the side that had a more acute angle before stent deployment.

🔖

Cite This Article

SAGLAM, M., KIZILKILIÇ, O., ANAGNOSTAKOU, V., YILDIZ, B., KOÇER, N., IŞLAK, C. (2015). Geometrical characteristics after Y-stenting of the basilar bifurcation. Diagnostic and Interventional Radiology, Cilt: 21 - Sayı: 6, 483–487. https://ajindex.com/articles/209735

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Van der Kolk NM, Algra A, Rinkel G. Risk of aneu- rysm rupture at intracranial arterial bifurcations. J Cerebrovasc Dis 2010
  2. [CrossRef] Hademenos GJ, Massoud TF. Biophysical mech- anisms of stroke. Stroke 1997
  3. [CrossRef] Takeuchi S, Karino T. Flow patterns and distri- butions of fluid velocity and wall shear stress in the human internal carotid and middle ce- rebral arteries. World Neurosurg 2010
  4. [CrossRef] Gao B, Baharoglu MI, Malek AM. Angular remod- eling in single stent-assisted coiling displaces and attenuates the flow impingement zone at the neck of intracranial bifurcation aneurysms. Neurosur- gery 2013
  5. [CrossRef] Meng H, Swartz DD, Wang Z, et al. A model sys- tem for mapping vascular responses to complex hemodynamics at arterial bifurcations in vivo. Neurosurgery 2006
  6. [CrossRef] Henkes H, Kirsch M, Mariushi W, Miloslavski E, Brew S, Kühne D. Coil treatment of a fusiform upper basilar trunk aneurysm with a combina- tion of "kissing" Neuroform stents, TriSpan-, 3D- and fibered coils, and permanent implantation of the microguidewires. Neuroradiology 2004
  7. [CrossRef] Klisch J, Eger C, Sychra V, Strasilla C, Basche S, Weber J. Stent-assisted coil embolization of posterior circulation aneurysms using soli- taire ab: preliminary experience. Neurosurgery 2009
  8. [CrossRef] Kono K, Terada T. Hemodynamics of 8 different configurations of stenting for bifurcation aneu- rysms. AJNR Am J Neuroradiol 2013
  9. [CrossRef] Zhao KJ, Yang PF, Huang QH, et al. Y-configuration stent placement (crossing and kissing) for endo- vascular treatment of wide-neck cerebral aneu- rysms located at 4 different bifurcation sites. AJNR Am J Neuroradiol 2012
  10. [CrossRef] Gao B, Baharoglu MI, Cohen AD, Malek AM. Stent-assisted coiling of intracranial bifurcation aneurysms leads to immediate and delayed in- tracranial vascular angle remodeling. AJNR Am J Neuroradiol 2012
  11. [CrossRef] Bendok BR, Parkinson RJ, Hage ZA, Adel JG, Gounis MJ. The effect of vascular reconstruc- tion device-assisted coiling on packing densi- ty, effective neck coverage, and angiographic outcome: an in vitro study. Neurosurgery 2007
  12. [CrossRef] Fargen KM, Hoh BL, Welch BG, et al. Long-term results of enterprise stent-assisted coiling of cerebral aneurysms. Neurosurgery 2012
  13. [CrossRef] Cekirge HS, Yavuz K, Geyik S, Saatci I. A novel "Y" stent flow diversion techn