Journals / Atmospheric Pollution Research / 2018 / Cilt: 9 - Sayı: 3

Field study on indoor air quality of urban apartments in severe cold region in China

Pages
552–560
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed that the indoor PM2.5 and PM10 during the space heating period, especially the haze weather period caused by heavy smog, were polluted seriously.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:An investigation on indoor air quality was carried out in urban apartments in Harbin, China.
📊
Key Findings & Data:The indoor and outdoor concentrations of PM2.5, PM10, CO, CO2, SO2, NOX, TVOC, HCHO and NH3 were monitored.
💡
Conclusion & Impact:The results showed that the indoor PM2.5 and PM10 during the space heating period, especially the haze weather period caused by heavy smog, were polluted seriously.
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

An investigation on indoor air quality was carried out in urban apartments in Harbin, China. The indoor and outdoor concentrations of PM2.5, PM10, CO, CO2, SO2, NOX, TVOC, HCHO and NH3 were monitored. Simultaneously, questionnaire surveys on the indoor perception of air quality among occupants were conducted. In addition, a continuous measure on indoor air pollutants was performed during cooking period and the indoor air quality in newly-decorated urban apartments was also studied. The results showed that the indoor PM2.5 and PM10 during the space heating period, especially the haze weather period caused by heavy smog, were polluted seriously. Good linear relationships between indoor and outdoor concentrations of PM were identified in the condition of terrible outdoor air quality. In contrast, the concentrations of HCHO, CO, CO2, NOX and SO2 approximately satisfied the requirements of national standard unless the serious haze weather occurred. According to the subjective surveys, occupants could evaluate the indoor ventilation correctly, but the indoor air quality was always overestimated. Moreover, the factor of illness history of the occupants had an obvious influence on the evaluation of indoor air quality. Furthermore, cooking increased the indoor concentrations of HCHO, CO and TVOC significantly, and the indoor air quality in newlydecorated urban apartments was heavily polluted by HCHO, NH3 and TVOC.

🔖

Cite This Article

TANG, R., WANG, Z. (2018). Field study on indoor air quality of urban apartments in severe cold region in China. Atmospheric Pollution Research, Cilt: 9 - Sayı: 3, 552–560. https://ajindex.com/articles/203687

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. ASHRAE Standard 62.1-2007., 2007. Ventilation for Acceptable Indoor Air Quality. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA. Begum, B.A., Paul, S.K., Hossain, M.D., Biswas, S.K., Hopke, P.K., 2009. Indoor air pollution from particulate matter emissions in different households in rural areas of Bangladesh. Build. Environ. 44, 898–903.
  2. Branco, P., Alvim-Ferraz, M., Martins, F., Sousa, S., 2014. Indoor air quality in urban nurseries at Porto city: particulate matter assessment. Atmos. Environ. 84, 133–143.
  3. Deng, G., Li, Z., Wang, Z., Gao, J., Xu, Z., Li, J., Wang, Z., 2015. Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing. Indoor Built Environ. 26 (1), 60–69.
  4. Deng, G., Li, Z., Wang, Z., Gao, J., Xu, Z., Li, J., Wang, Z., 2017. Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing. Indoor Built Environ. 26, 60–68.
  5. Fan, G., Xie, J., Liu, J., Yoshino, H., 2017. Investigation of indoor environmental quality in urban dwellings with schoolchildren in Beijing, China. Indoor Built Environ. 26, 694–716. G.T. 18883-2002, 2002. Indoor Air Quality Standard of the People's Republic of China. (in Chinese). Guo, H., Morawska, L., He, C., Zhang, Y.L., Ayoko, G., Cao, M., 2010. Characterization of particle number concentrations and PM2.5 in a school: influence of outdoor air pollution on indoor air. Environ. Sci. Pollut. Res. 17, 1268–1278.
  6. Jiang, R., Bell, M.L., 2008. A comparison of particulate matter from biomass-burning rural and non-biomass-burning urban households in northeastern China. Environ. Health Perspect. 116, 907–914.
  7. Jones, A.P., 1999. Indoor air quality and health. Atmos. Environ. 33, 4535–4564.
  8. Kalimeri, K.K., Saraga, D.E., Lazaridis, V.D., Legkas, N.A., Missia, D.A., Tolis, E.I., Bartzis, J.G., 2016. Indoor air quality investigation of the school environment and estimated health risks: two-season measurements in primary schools in Kozani, Greece. Atmos. Pollut. Res. 7 (6), 1128–1142.
  9. Mainka, A., Brągoszewska, E., Kozielska, B., Pastuszka, J.S., Zajusz-Zubek, E., 2015. Indoor air quality in urban nursery schools in Gliwice, Poland: analysis of the case study. Atmos. Pollut. Res. 6 (6), 1098–1104.
  10. Massey, D.D., Kulshrestha, A., Masih, J., Taneja, A., 2012. Seasonal trends of PM10, PM5.0, PM2.5 & PM1.0 in indoor and outdoor environments of residential homes located in North-Central India. Bu