Journals / Turkish Journal of Veterinary and Animal Sciences / 2003 / Cilt: 27 - Sayı: 5

Color Doppler Imaging of the Internal Ophthalmic and Long Posterior Ciliary Arteries in the Dog

Pages
1219–1224
Publication Date
2003-05-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result, since CDI is a reliable and easily applicable method for detecting eye vessel blood velocity parameters, such as the IOA and LPCA, it can be recommended for investigating ophthalmic vessel disorders in dogs.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The objective of this study was to demonstrate the specific blood velocity parameters called peak systolic velocity (PSV), end diastolic velocity (EDV) and the resistive index (RI) in the internal ophthalmic artery (IOA) and the long posterior ciliary artery (LPCA) with color Doppler imaging (CDI) in clinically normal dogs.
📊
Key Findings & Data:The mean RI of the IOA was 0.57 ± 0.095 cm/s and that of the LPCA was 0.58 ± 0.083 cm/s.
💡
Conclusion & Impact:As a result, since CDI is a reliable and easily applicable method for detecting eye vessel blood velocity parameters, such as the IOA and LPCA, it can be recommended for investigating ophthalmic vessel disorders in dogs.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Doppler · ophthalmic · artery

Abstract

The objective of this study was to demonstrate the specific blood velocity parameters called peak systolic velocity (PSV), end diastolic velocity (EDV) and the resistive index (RI) in the internal ophthalmic artery (IOA) and the long posterior ciliary artery (LPCA) with color Doppler imaging (CDI) in clinically normal dogs. Eight healthy dogs were used in the study. Color Doppler ultrasonography was performed on both eyes. PSV, EDV and RI measurements were obtained for both eyes. The mean RI of the IOA was 0.57 ± 0.095 cm/s and that of the LPCA was 0.58 ± 0.083 cm/s. The RI values did not differ significantly between the right and left eyes. As a result, since CDI is a reliable and easily applicable method for detecting eye vessel blood velocity parameters, such as the IOA and LPCA, it can be recommended for investigating ophthalmic vessel disorders in dogs.

Özet

The objective of this study was to demonstrate the specific blood velocity parameters called peak systolic velocity (PSV), end diastolic velocity (EDV) and the resistive index (RI) in the internal ophthalmic artery (IOA) and the long posterior ciliary artery (LPCA) with color Doppler imaging (CDI) in clinically normal dogs. Eight healthy dogs were used in the study. Color Doppler ultrasonography was performed on both eyes. PSV, EDV and RI measurements were obtained for both eyes. The mean RI of the IOA was 0.57 ± 0.095 cm/s and that of the LPCA was 0.58 ± 0.083 cm/s. The RI values did not differ significantly between the right and left eyes. As a result, since CDI is a reliable and easily applicable method for detecting eye vessel blood velocity parameters, such as the IOA and LPCA, it can be recommended for investigating ophthalmic vessel disorders in dogs.

🔖

Cite This Article

ŞINDAK, N. (2003). Color Doppler Imaging of the Internal Ophthalmic and Long Posterior Ciliary Arteries in the Dog. Turkish Journal of Veterinary and Animal Sciences, Cilt: 27 - Sayı: 5, 1219–1224. https://ajindex.com/articles/201501

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...