Journals / Turkish Journal of Chemistry / 2021 / Cilt: 45 - Sayı: 1

A new electrochemical impedance biosensor based on aromatic thiol for alpha-1 antitrypsin determination

Pages
104–118
Publication Date
2021-02-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

A1AT detection was also successfully carried out in artificial serum solutions spiked with A1AT.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Alpha-1 antitrypsin (A1AT) is one of the acute phase proteins which are synthesized in the liver.
📊
Key Findings & Data:A1AT inhibits the activity of many proteases, but its main task is to protect the lungs from the attack of neutrophil elastase.
💡
Conclusion & Impact:A1AT detection was also successfully carried out in artificial serum solutions spiked with A1AT.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Alpha-1 antitrypsin · electrochemical immunosensor · 4-mercaptophenylacetic acid

Abstract

Alpha-1 antitrypsin (A1AT) is one of the acute phase proteins which are synthesized in the liver. A1AT inhibits the activity of many proteases, but its main task is to protect the lungs from the attack of neutrophil elastase. In an autosomal hereditary disease known as alpha-1 antitrypsin deficiency, the A1AT level in blood serum decreases, increasing the risk of developing emphysema, liver apoptosis, and liver cancer. Thus, the detection of A1AT concentration in blood serum is very important. In this study, an impedimetric biosensor was developed, forming an SAM (self-assembled monolayer) with 4-mercaptophenylacetic acid (4MPA) on the surface of the gold electrode. An A1AT biosensor was constructed using immobilization of an A1AT-specific antibody (anti-A1AT) after activating the carboxyl groups of 4MPA with EDC/NHS. Each immobilization stage was characterized by using electrochemical impedance spectroscopy, cyclic voltammetry, and scanning electron microscopy with energy dispersive X-ray spectroscopy. With the designed biosensor, precise and highly reproducible results were obtained for A1AT concentrations in the range of 100-600 mu g/mL. A1AT detection was also successfully carried out in artificial serum solutions spiked with A1AT.

🔖

Cite This Article

YAGAR, H., OZCAN, H. M., MEHMET, O. (2021). A new electrochemical impedance biosensor based on aromatic thiol for alpha-1 antitrypsin determination. Turkish Journal of Chemistry, Cilt: 45 - Sayı: 1, 104–118. https://ajindex.com/articles/201338

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Ahmad A, 2012,
  2. ANALYST, V137, P5839, DOI 10.1039/c2an35236b [Anonymous], 1997, B WORLD HEALTH ORGAN, V75, P397 Asav E, 2016,
  3. ELECTROANAL, V28, P334, DOI 10.1002/elan.201500324 Asav E, 2014, INT J BIOL MACROMOL, V66, P273, DOI 10.1016/j.ijbiomac.2014.02.032 Aydin EB, 2017, BIOSENS BIOELECTRON, V97, P169, DOI 10.1016/j.bios.2017.05.056 Aydin M, 2019, BIOSENS BIOELECTRON, V126, P230, DOI 10.1016/j.bios.2018.10.051 Aydin M, 2018, BIOSENS BIOELECTRON, V117, P720, DOI 10.1016/j.bios.2018.07.010 BLANCO I, 2017, BLANC OV ALPH ANT, P1. BRANTLY M, 1988, AM J MED, V84, P13. Chaki NK, 2002, BIOSENS BIOELECTRON, V17, P1, DOI 10.1016/S0956-5663(01)00277-9 CRYSTAL RG, 1990, J CLIN INVEST, V85, P1343, DOI 10.1172/JCI114578 Ferrera I, 2015, PLOS ONE, V10, DOI 10.1371/journal.pone.0118136 Hewas AM, 2013, ANAL METAL IONS WATE. HUBBARD RC, 1988, AM J MED, V84, P52. Jain S, 2011, J PHARM BIOALLIED SC, V3, P118, DOI 10.4103/0975-7406.76489 JONES EA, 1978, CLIN SCI MOL MED, V55, P139, DOI 10.1042/cs0550139 Kim S, 2015, ANAL CHEM, V87, P7235, DOI 10.1021/acs.analchem.5b01192 Kohnlein T, 2008, AM J MED, V121, P3, DOI 10.1016/j.amjmed.2007.07.025 Lanzellotto C, 2014, BIOSENS BIOELECTRON, V55, P430, DOI 10.1016/j.bios.2013.12.028 LAVIRON E, 1979, J ELECTROANAL CHEM, V101, P19, DOI 10.1016/S0022-0728(79)80075-3 Li JH, 1997, ELECTROCHIM ACTA, V42, P961, DOI 10.1016/S0013-4686(96)00273-3 McNaught A.D., 1997, COMPENDIUM CHEM TERM Meseeha M, 2020, ALPHA 1 ANTITRYPSIN. Ozcan HM, 2015, BIOTECHNOL PROGR, V31, P815, DOI 10.1002/btpr.2060 Reeves EP, 2019, J IMMUNOL, V202, P2240, DOI 10.4049/jimmunol.1801045 Sanchez-Paniagua M, 2020,
  4. TALANTA, V212, DOI 10.1016/j.talanta.2020.120735 Sezginturk MK, 2012, ANAL BIOCHEM, V423, P277, DOI 10.1016/j.ab.2011.12.049 Soares IP, 2019, J SOLID STATE ELECTR, V23, P985, DOI 10.1007/s10008-019-04204-w Song F, 2009, BRAIN RES REV, V61, P69, DOI 10.1016/j.brainresrev.2009.05.003 Subramaniyam D, 2006, INT J BIOCHEM CELL B, V38, P563, DOI 10.1016/j.biocel.2005.09.021 Talemi RP, 2015,
  5. TALANTA, V131, P460, DOI 10.1016/j.talanta.2014.08.009 Tlili A, 2004, SENSORS-BASEL, V4, P105, DOI 10.3390/s40670105 Nguyen VH, 2017, SENSORS-BASEL, V17, DOI 10.3390/s17122931 Yagati AK, 2013, BIOSENS BIOELECTRON, V47, P385, DOI 10.1016/j.bios.2013.03.035 Zhu GB, 2017, BIOSENS BIOELECTRON, V89, P959, DOI 10.1016/j.bios.2016.09.080