Journals / Electrica / 2021 / Cilt: 21 - Sayı: 1

Performance Analysis of Implanted Hybrid Three Quasi Z source Inverter designed for Renewable Energy Conversion Applications

Journal
Electrica
Pages
1–9
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Simulation results using MATLAB software are presented for the validation of the proposed work under the conditions of input voltage variations as well as a sudden change of loads

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Implanted hybrid three quasi Z source inverter has been designed to achieve high voltage gain for a single-stage power conversion system.
📊
Key Findings & Data:The net input voltage applied to the converter is the sum of the voltages of four independent sources to which the converter is configured.
💡
Conclusion & Impact:Simulation results using MATLAB software are presented for the validation of the proposed work under the conditions of input voltage variations as well as a sudden change of loads
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Implanted hybrid three quasi Z source inverter has been designed to achieve high voltage gain for a single-stage power conversion system. The net input voltage applied to the converter is the sum of the voltages of four independent sources to which the converter is configured. It is a fact that the power from renewable energy sources will not be constant and varies. So there is uncertainty in the uniform availability of energy from renewable energy sources and the resulting voltage variations in any of the four sources affects net input voltage of the converter. A dual-loop control method has been developed to control the dc-link voltage across the converter to attain a constant ac output voltage across load terminals and meet load requirements. The controller maintains the stable operation of the converter in the absence of any of the four voltage sources. Simulation results using MATLAB software are presented for the validation of the proposed work under the conditions of input voltage variations as well as a sudden change of loads

🔖

Cite This Article

ALLA, R., CHOWDHURY, A. (2021). Performance Analysis of Implanted Hybrid Three Quasi Z source Inverter designed for Renewable Energy Conversion Applications. Electrica, Cilt: 21 - Sayı: 1, 1–9. https://ajindex.com/articles/198843

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. F. Z. Peng, “Z-source inverter”, IEEE Transactions on Industry Applications, vol. 39, No.2, pp. 504-510, March-April, 2003. [CrossRef] 2. J. Anderson, F.Z. Peng, “Four Quasi-Z-Source Inverters”, 2008 IEEE Power Electronics Specialists Conference, Rhodes, Greece, August 2008, pp. 2743-2749. [CrossRef] 3. O. Ellabban, H. Abu-Rub, “Z Source Inverter: Topology Improvements Review” IEEE Industrial Electronics magazine, vol.10, No.1, pp. 6-24, March, 2016. [CrossRef] 4. Yam P. Siwakoti, F. Blaabjerg, P. C. Loh, “New Magnetically Coupled Impedance (Z-) Source Networks” IEEE Transactions on Power Electronics, Vol. 31, No. 11, pp. 7419-7435, November, 2016. [CrossRef] 5. Y. P. Siwakoti, P. C. Loh, F. Blaabjerg, G. E. Town, “Effects of Leakage Inductances on Magnetically Coupled Y-Source Network”, IEEE Transactions on Power Electronics, Vol. 29, No. 11, pp. 5662-5666, November, 2014. [CrossRef] 6. H. Liu, Z. Zhou, K. Liu, P. C. Loh, W. Wang, D. Xu, F. Blaabjerg, “A Family of High Step-Up Coupled-Inductor Impedance-Source Inverters With Reduced Switching Spikes”, IEEE Transactions on Power Electronics, Vol. 33, No. 11, pp. 9116 – 9121, November, 2018. [CrossRef] 7. A. Abdelhakimr, F. Blaabjerg, P. Mattavelli, “Modulation Schemes of the Three-Phase Impedance Source Inverters—Part I: Classification and Review”, IEEE Transactions on Industrial Electronics, Vol. 65, No. 8, pp. 6309 – 6320, August, 2018. [CrossRef] 8. O. Ellabban, H. Abu-Rub, “An overview for the Z-Source Converter in motor drive applications”, Renewable and Sustainable Energy Reviews Vol.61 pp. 537–555, August, 2016. [CrossRef] 9. J. Zhang, “Unified control of Z-source grid-connected photovoltaic system with reactive power compensation and harmonics restraint: design and application”, IET Renewable Power Genereration, Vol. 12, No. 4, pp. 422-429, March, 2018. [CrossRef] 10. Q. Tran, T. Chun, J. Ahn, H. Lee, “Algorithms for Controlling Both the DC Boost and AC Output Voltage of Z-Source Inverter”, IEEE Transactions on Industrial Electronics, Vol. 54, No. 5, pp. 2745 – 2750, October, 2007. [CrossRef] 11. H. Liu, P. Liu, Y. Zhang, “Design and digital implementation of voltage and current mode control for the quasi-Z-source converters”, IET Power Electronics, Vol. 6, No. 5, pp. 990–998, June, 2013. [CrossRef] 12. H. Shen, B. Zhang, D. Qiu, “Hybrid Z-Source Boost DC–DC Converters”, IEEE Transactions Industrial Electronics, Vol. 64, No. 1 pp. 310 – 319, January, 2017. [CrossRef] 13. E. Babaei, E. S. Asl, “A