Journals / Electrica / 2021 / Cilt: 21 - Sayı: 1

State of Research on Effects of Cloud to Ground Lightning Transients on High Voltage Polymeric Insulated Power Cables

Journal
Electrica
Pages
58–65
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

This review brings to the light that while transients response against standard 1.2/50 µs lightning waveform is relatively well studied but more work needs to be further undertaken to fully appreciate the behaviour of insulted power cables against the non-standard lightning transient waveforms which are more prevalent in actual field.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Lightning continues to possess threats to the reliable supply of electrical energy by causing damages to electrical equipment.
📊
Key Findings & Data:Lightning transient causes outages either by directly hitting electrical equipment or by the electromagnetic interference induced by it upon hitting the ground near to the equipment.
💡
Conclusion & Impact:This review brings to the light that while transients response against standard 1.2/50 µs lightning waveform is relatively well studied but more work needs to be further undertaken to fully appreciate the behaviour of insulted power cables against the non-standard lightning transient waveforms which are more prevalent in actual field.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Lightning continues to possess threats to the reliable supply of electrical energy by causing damages to electrical equipment. Lightning transient causes outages either by directly hitting electrical equipment or by the electromagnetic interference induced by it upon hitting the ground near to the equipment. An electrical equipment which is witnessing a rise in application over the years are the insulated power cables. Use of these cables are not only confined to transferring electrical energy over distances but they are also used as transformer winding in a type of transformer pioneered by ABB called powerformers. Using XLPE insulated power cables as a case in point, the present study seeks to unravel the trajectory of research undertaken so far in this area of transient behaviour of insulated power cables against lightning transients. In particular, attention has been focused on the response of insulated power cables against non-standard lightning transient voltage waveforms. This review brings to the light that while transients response against standard 1.2/50 µs lightning waveform is relatively well studied but more work needs to be further undertaken to fully appreciate the behaviour of insulted power cables against the non-standard lightning transient waveforms which are more prevalent in actual field.

🔖

Cite This Article

TARO, M., CHATTERJEE, S. (2021). State of Research on Effects of Cloud to Ground Lightning Transients on High Voltage Polymeric Insulated Power Cables. Electrica, Cilt: 21 - Sayı: 1, 58–65. https://ajindex.com/articles/198011

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. M. A. Uman, “The Art and Science of Lightning Protection”, Cambridge University Press,
  2. New York, USA, 2008. [CrossRef] 2. CIGRE Working Group C4, 407 (2013) Lightning Parameters for Engineering Applications, CIGRE Technical Brochure 549. 3. E. Karami, A. Khalilinia, A. Bali, K. Rouzbehi, “Monte-Carlo-based simulation and investigation of 230 kV transmission lines outage due to lightning”, IET High Voltage, March, 2020, vol. 5 no. 1, pp. 83-91. [CrossRef] 4. X. Liu, M. Zhang, T. Wang, Y. Ge, “Fast evaluation of lightning-induced voltages of overhead line and buried cable considering the lossy ground”, in IET Science, Measurement & Technology, vol. 13, no. 1, pp. 67-73, January, 2019. [CrossRef] 5. I. A. Metwally, “The Evolution of Medium Voltage Power Cables”, IEEE Potentials, vol. 31, no. 3, pp: 20 – 25, May-June, 2012. [CrossRef] 6. L. Gkoura, T. Wang, A. Anastasiou, N. Harid, H. Griffiths, M. Haddad, M. Fardis, M. Karayianni, “1 H NMR tests on damaged and undamaged XLPE and SiR Samples”, IET High Voltage, October, 2019, vol. 4 no. 3, pp. 203-209. [CrossRef] 7. IEEE Standard for High-Voltage Testing Techniques, IEEE Std 4-2013 (Revision of IEEE Std 4-1995), 10 May 2013. 8. P. Chowdhuri, A. C. Baker, G. Carrara, W. A. Chisholm, K. Feser, S. Grzybowski, A. Lux, F. R. Newnam, “Review of research on nonstandard lightning voltage waves”, in IEEE Transactions on Power Delivery, vol. 9, no. 4, pp. 1972-1981, October, 1994. [CrossRef] 9. W. Sima, P. Sun, M. Yang, J. Wu, J. Hua, “Impact of time parameters of lightning impulse on the breakdown characteristics of oil paper insulation”, IET High Voltage, April, 2016, vol. 1, no. 1, pp. 18–24. [CrossRef] 10. M. Shigihara, A. Piantini, C. P. Braz, D. A. da Silva, C. Y. Kodaira, “Generation of Non-standard Lightning Impulse Unipolar Waveshapes”, 2018 IEEE International Conference on High Voltage Engineering and Application (ICHVE), ATHENS, Greece, September, 2018, pp. 1-4. [CrossRef] 11. M. Paolone, C. A. Nucci, E. Petrache, F. Rachidi, “Mitigation of lightning-induced overvoltages in medium voltage distribution lines by means of periodical grounding of shielding wires and of surge arresters: modeling and experimental validation”, IEEE Trans. Power Delivery, vol. 19, no. 1, pp. 423 - 431, January, 2004. [CrossRef] 12. S. Venkatesan, S. Usa, “Impulse Strength of Transformer Insulation With Nonstandard Waveshapes”, IEEE Transactions on Power Delivery, vol. 22, no. 4, October, 2007. [CrossRef] 13. S. Okabe, J. Takami, T