Journals / Electrica / 2021 / Cilt: 21 - Sayı: 1

Quantitative Phase Macroscopic System for Label-Free Imaging of Tissue Sections

Journal
Electrica
Pages
10–19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

A software level stitching further enlarges the effective field of view.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Optical microscopes are typically designed as versatile tools that are capable of imaging at various modalities with different resolutions in respective visual fields.
📊
Key Findings & Data:A large extend of versatility causes increased complexity, size, and the cost.
💡
Conclusion & Impact:A software level stitching further enlarges the effective field of view.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Optical microscopes are typically designed as versatile tools that are capable of imaging at various modalities with different resolutions in respective visual fields. A large extend of versatility causes increased complexity, size, and the cost. Imaging of tissue sections is a routine procedure in clinics and research laboratories. Tissue staining consumables, required time for staining along with the cost of the imaging systems are the limiting factors for widespread use. A multimode imaging system with enhanced resolution performance and automation is generally superfluous for the coarse resolution imaging of tissue sections. A dedicated system for label free tissue section imaging is presented. Label free imaging with high contrast is provided in form of quantitative phase. Earlier demonstrations of quantitative phase imaging of tissue sections utilized modified microscopes with different modalities for correlated imaging and motorized stages for field enlargement. Here, the system follows an off-axis digital holographic imaging configuration for the acquisition of quantitative phase at single shot. The system compromises from the resolution and magnification of a traditional microscope for the size of visual field, ease of use, and relative cost due to the exclusion of sample stages. A software level stitching further enlarges the effective field of view.

🔖

Cite This Article

TOY, M. F. (2021). Quantitative Phase Macroscopic System for Label-Free Imaging of Tissue Sections. Electrica, Cilt: 21 - Sayı: 1, 10–19. https://ajindex.com/articles/198010

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Y. Park, C. Depeursinge, G. Popescu, “Quantitative phase imaging in biomedicine”, Nature Photonics, vol. 12, no. 10, pp. 578-589, September, 2018. [CrossRef] 2. B. Kemper, G. von Bally, “Digital holographic microscopy for live cell applications and technical inspection”, Applied Optics, vol. 47, no. 4, pp. A52-A61, February, 2008. [CrossRef] 3. K. M. Kim, “Principles and techniques of digital holographic microscopy”, SPIE reviews, vol. 1, no. 1, p.018005, April, 2010. [CrossRef] 4. U. Schnars, W. Jüptner, “Direct recording of holograms by a ccd target and numerical reconstruction”, Applied Optics, vol. 33, no. 2, pp. 179-181, January, 1994. [CrossRef] 5. E. Cuche, F. Bevilacqua, C. Depeursinge, “Digital holography for quantitative phase-contrast imaging”, Optics Letters, vol. 24, no. 5, pp. 291-293, March, 1999. [CrossRef] 6. E. Cuche, P. Marquet, C. Depeursinge, “Simultaneous amplitude-contrast and quantitative phase-contrast microscopy by numerical reconstruction of Fresnel off-axis holograms”, Applied Optics vol. 38, no. 34, pp. 6994-7001, December, 1999. [CrossRef] 7. U. Schnars, W. Juptner, “Digital recording and numerical reconstruction of holograms”, Measurement Science and Technology, vol. 13, no. 9, pp. R85-R101, August, 2002. [CrossRef] 8. F. Montfort, Y. Emery, F. Marquet, E. Cuche, N. Aspert, E. Solanas, A. Mehdaoui, A. Ionescu, C. Depeursinge, “Process engineering and failure analysis of MEMS and MOEMS by Digital Holography Microscopy (DHM)”, in Reliability, Packaging, Testing, and Characterization of MEMS/MOEMS VI, Proceedings of SPIE 6463, San Jose, January, 2007, pp. 64630G-1 - 64630G-7. [CrossRef] 9. D. A. Silage, J. Gil, “Digital image tiles: a method for the processing of large sections”, Journal of Microscopy. vol. 138, no. 2, pp. 221- 227, May,1985. [CrossRef] 10. M. C. Montalto, R. R. McKay, R. J. Filkins, “Autofocus methods of whole slide imaging systems and the introduction of a second-generation independent dual sensor scanning method”, Journal of Pathology Informatics, vol. 2, 2011. [CrossRef] 11. M. G. Rojo, G. B. García, C. P. Mateos, J. G. García, M. C. Vicente, “Critical comparison of 31 commercially available digital slide systems in pathology”, International Journal of Surgical Pathology, vol. 14, no. 4, pp. 285-305, October, 2006. [CrossRef] 12. G. Bueno, O. Déniz, M. D. M. Fernández‐Carrobles, N. Vállez, J. Salido, “An automated system for whole microscopic image acquisition and analysis”, Microscopy Research and Techni