A hybrid approach for power quality monitoring

Pages
854–869
Publication Date
2012-06-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The test results demonstrate the potential of the proposed hybrid technique for PQM andPQ assessment.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper presents a novel hybrid approach for detection of power quality (PQ) disturbances.
📊
Key Findings & Data:The proposed PQ monitoring (PQM) software uses 3-phase voltage and current signals in order to detect possible power disturbances such as voltage sag, flicker, harmonics, transients, DC component, and electromagnetic interference.
💡
Conclusion & Impact:The test results demonstrate the potential of the proposed hybrid technique for PQM andPQ assessment.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Power quality · discrete wavelet transform · principal component analysis

Abstract

This paper presents a novel hybrid approach for detection of power quality (PQ) disturbances. The proposed hybrid algorithm is based on applications of principle component analysis, discrete wavelet transform, and fast Fourier transform on voltage and current waveforms. The proposed PQ monitoring (PQM) software uses 3-phase voltage and current signals in order to detect possible power disturbances such as voltage sag, flicker, harmonics, transients, DC component, and electromagnetic interference. The test results demonstrate the potential of the proposed hybrid technique for PQM andPQ assessment.

Özet

This paper presents a novel hybrid approach for detection of power quality (PQ) disturbances. The proposed hybrid algorithm is based on applications of principle component analysis, discrete wavelet transform, and fast Fourier transform on voltage and current waveforms. The proposed PQ monitoring (PQM) software uses 3-phase voltage and current signals in order to detect possible power disturbances such as voltage sag, flicker, harmonics, transients, DC component, and electromagnetic interference. The test results demonstrate the potential of the proposed hybrid technique for PQM andPQ assessment.

🔖

Cite This Article

ÖZGÖNENEL, O., TERZİ, Ü. K., KHAN, A. (2012). A hybrid approach for power quality monitoring. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 20 - Sayı: 6, 854–869. https://ajindex.com/articles/188723

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. T.D. Unruh, “Application techniques for power quality monitoring”, IEEE/PES Transmission and Distribution Conference and Exposition, pp. 1-2, 2008. Z. Hongliang, “GPRS based power quality monitoring system”, Proceedings of the IEEE International Conference on Networking, Sensing and Control, pp. 496-501, 2005. E. ¨Ozdemirci, Y. Akkaya, B. Boyrazo˘glu, S. Buhan, A. Terciyanlı, ¨O. ¨Unsar, E. Altınta¸s, B. Halilo˘glu, A. A¸cık, T. Atalık, ¨O. Salor, T. Demirci, I. Cadırcı, M. Ermi¸s, “Mobile monitoring system to take PQ snapshots of Turkish electricity transmission system”, Proceedings of the Instrumentation and Measurement Technology Conference, pp. 1-6, 2008.
  2. T. Demirci, A. Kalaycıo˘glu, ¨O. Salor, S. Pakhuylu, T. ˙Inan, D. K¨u¸c¨uk, M. G¨uder, T. Can, Y. Akkaya, S. Bilgen, I. C¸ adırcı, M. Ermi¸s, “National power quality monitoring network and assessment center for the Turkish electric- ity transmission system: recent developments”, IEEE 16th Signal Processing, Communication and Applications Conference, pp. 1-4, 2008.
  3. P. Santarius, P. Krejci, Z. Chmelikova, J. Ciganek, “Long-term monitoring of power quality parameters in regional distribution networks in the Czech Republic”, 9th International Conference on Harmonics and Quality of Power, pp. 1-5, 2008.
  4. Y.H. Chen, M.J. Cheng, L.C. Hwang, J.H. Teng, “Embedded web server based power quality recorder”, Proceedings of the IEEE Region 10 Conference, pp. 1-6, 2005.
  5. Z. Lu, J.S. Smith, H. Wu, J. Fitch, “Empirical mode decomposition for power quality monitoring”, IEEE/PES Transmission and Distribution Conference and Exhibition: Asia and PaciŞc, pp. 1-5, 2005.
  6. M.A. Eldery, E.F. El-Saadany, M.M.A. Salama, A. Vannelli, “A novel power quality monitoring allocation algo- rithm”, IEEE Transactions on Power Delivery, Vol. 21, pp. 768-777, 2006.
  7. M.E. Salem, A. Mohamed, S.A. Samad, R. Mohamed, “Development of a DSP-based power quality monitoring instrument for real-time detection of power disturbances”, International Conference on Power Electronics and Drives Systems, pp. 304-307, 2005.
  8. D. Hong, J. Lee, J. Choi, “Power quality monitoring system using power line communication”, Fifth International Conference on Information, Communications and Signal Processing, pp. 931-935, 2005.
  9. W. Kang, X. Yan, H. Li, L. Zhang, “Design and realization of power quality monitoring system based on DSP and PCI technique”, 12th International Power Electronics and Motion Control Conference, pp. 420-424, 2006.
  10. V.A. Tukhas, S.A. Eintrop, “System o