Journals / Turkish Journal of Electrical Engineering and Computer Science / 2013 / Cilt: 21 - Sayı: Sup.1

Survey of power quality in Turkish national transmission network

Pages
1880–1892
Publication Date
2012-12-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Moreover, the measurement results are compared to the current regulations in Turkey.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Harmonic distortion and flicker severity have become the main concerns in power transmission networks.
📊
Key Findings & Data:The aim of this study is to identify the level of harmonics and flicker in the 380-kV transmission network of Turkey.
💡
Conclusion & Impact:Moreover, the measurement results are compared to the current regulations in Turkey.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Transmission network · power quality · harmonic

Abstract

Harmonic distortion and flicker severity have become the main concerns in power transmission networks. Different types of harmonic and flicker sources exist in power systems, such as arc furnaces and cycloconverters. A power quality problem found in networks can cause additional temperature rise, losses, noise, and irritation in the lighting equipment. The aim of this study is to identify the level of harmonics and flicker in the 380-kV transmission network of Turkey. The measurement and analysis are performed using a specially developed power quality analyzer. The effects of harmonics and flicker on the network are discussed based on real measurement results. Moreover, the measurement results are compared to the current regulations in Turkey.

Özet

Harmonic distortion and flicker severity have become the main concerns in power transmission networks. Different types of harmonic and flicker sources exist in power systems, such as arc furnaces and cycloconverters. A power quality problem found in networks can cause additional temperature rise, losses, noise, and irritation in the lighting equipment. The aim of this study is to identify the level of harmonics and flicker in the 380-kV transmission network of Turkey. The measurement and analysis are performed using a specially developed power quality analyzer. The effects of harmonics and flicker on the network are discussed based on real measurement results. Moreover, the measurement results are compared to the current regulations in Turkey.

🔖

Cite This Article

KOCATEPE, C., KEKEZOĞLU, B., BOZKURT, A., YUMURTACI, R. (2012). Survey of power quality in Turkish national transmission network. Turkish Journal of Electrical Engineering and Computer Science, Cilt: 21 - Sayı: Sup.1, 1880–1892. https://ajindex.com/articles/188580

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. IEC, IEC 61000-4-30, Electromagnetic Compatibility (EMC) – Part 4: Testing and Measurement Techniques, Power Quality Measurement Methods, 2003.
  2. IEEE, Std. 519-1992, IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems, 1993. C. Muscas, “Power quality monitoring in modern electric distribution systems”, IEEE Instrumentation & Measurement Magazine, Vol. 13, pp. 19–27, 2010.
  3. C. Zhu, M. Hu, Z. Wu, X. Dou, S. Zhao, “Design and realization of regional power quality monitoring system”, Electric Utility Deregulation and Restructuring and Power Technologies, pp. 2023–2027, 2008. E. ¨ Ozdemirci, Y. Akkaya, B. Boyrazo˘ glu, S. Buhan, A. Terciyanlı, ¨ O. ¨ Unsar, E. Altinta¸s, B. Halilo˘ glu, A. A¸ cık, T. Atalık, ¨ O. Salor, T. Demirci, I. C ¸ adırcı, M. Ermi¸s, “Mobile monitoring system to take PQ snapshots of Turkish Electricity Transmission System”, IMTC, pp. 1–6, 2007.
  4. R.J.R. Gomes, D.O.C. Brasil, D.M. Correia, A.M. Monteiro, J.R. Medeiros, D.S. Araujo, “Brazilian transmission system power quality indices”, 13th International Conference on Harmonics and Quality of Power, pp. 231–237, 200 M.R. Qader, M.H.J. Bollen, R.N. Allan, “Stochastic prediction of voltage sags in a large transmission system”, IEEE Transactions on Industry Applications, Vol. 35, pp. 152–162, 1999.
  5. V. Thiyagarajan, T.G. Palanivel, “An efficient monitoring of substations using microcontroller based monitoring system”, International Journal of Research and Reviews in Applied Sciences, Vol. 4, pp. 63–68, 2010. A. Apostolov, “Web-enabled power quality monitoring in small distribution substations”, 17th International Conference on Electricity Distribution, pp. 1–6, 2003.
  6. S. Nath, A. Dey, A. Chakrabarti, “Detection of power quality disturbances using wavelet transform”, World Academy of Science, Engineering and Technology 49, pp. 869–873, 2009.
  7. T. Demirci, A. Kalaycıo˘ glu, D. K¨ u¸ c¨ uk, ¨ O. Salor, M. G¨ uder, S. Pakhuylu, T. Atalık, T. ˙Inan, I. C ¸ adırcı, Y. Akkaya, S. Bilgen, M. Ermi¸s, “Nationwide real-time monitoring system for electrical quantities and power quality of the electricity transmission system”, IET Generation, Transmission & Distribution, Vol. 5, pp. 540–550, 2011. B. Kekezo˘ glu, C. Kocatepe, R. Yumurtaci, O. Arikan, M. Baysal, A. Bozkurt, Y. Akkaya, E. ¨ Ozdemir, “Investigation of harmonic effect in Turkey’s iron-steel industry”, 6th International Conference on Power Quality and Supply Reliability, pp. 29–34, 2008. ¨ O. Salor, B. G¨ ult