Journals / Turkish Journal of Chemistry / 2017 / Cilt: 41 - Sayı: 5

A new method for simultaneous determination of trace amounts of Cu(II) and Ni(II) ions by preconcentration and spectrophotometric analysis

Pages
619–629
Publication Date
2017-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results of the proposed method were also compared with inductively coupled plasma-mass spectrometry results for the determination of trace Cu(II) and Ni(II) ions in water samples.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Immediate preconcentration and spectrophotometric methods have been developed for the determination of trace amounts of cupric ion (Cu(II)) and nickel ion (Ni(II)) through a solid phase extraction with XAD-4-N,N'-bis-(salicylidene) cyclohexanediamine (XAD-4-SCHD) resin and a complex color reaction of the ions with 2,6-dimethyl-morpholine dithiocarbamate (DMMDTC) in Triton X-100 media.
📊
Key Findings & Data:A high preconcentration factor of 125 was achieved.
💡
Conclusion & Impact:Results of the proposed method were also compared with inductively coupled plasma-mass spectrometry results for the determination of trace Cu(II) and Ni(II) ions in water samples.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Spectrophotometric method development · solid phase extraction · Cu(II)

Abstract

Immediate preconcentration and spectrophotometric methods have been developed for the determination of trace amounts of cupric ion (Cu(II)) and nickel ion (Ni(II)) through a solid phase extraction with XAD-4-N,N'-bis-(salicylidene) cyclohexanediamine (XAD-4-SCHD) resin and a complex color reaction of the ions with 2,6-dimethyl-morpholine dithiocarbamate (DMMDTC) in Triton X-100 media. A high preconcentration factor of 125 was achieved. The spectrophotometric method was based on the measurements of the absorption of colored chelates of ions complexing with DMMDTC, and the adsorptions of the complex solutions were measured at their maximum absorption peaks at 460 and 328 nm for Cu(II) and Ni(II) ions, respectively. The impact of the complexing reaction variables including type and amount of surfactant, pH, amount of ligand, and complexation time on the sensitivity of the proposed method was optimized. Calibration graphs were found to be linear in the ranges of 0.02-3 and 0.02-2.5 mg L$^{-1}$ with detection limits of 5 and 7 $\mu $g L$^{-1}$ for Cu(II) and Ni(II), respectively. The accuracy of the developed method was calculated by recovering all Cu(II) and Ni(II) ions in synthetic and TMDA-70.2 certified reference water samples. Results of the proposed method were also compared with inductively coupled plasma-mass spectrometry results for the determination of trace Cu(II) and Ni(II) ions in water samples.

🔖

Cite This Article

TOPUZ, B., ADANUR, Ş. M., YALÇUK, A. (2017). A new method for simultaneous determination of trace amounts of Cu(II) and Ni(II) ions by preconcentration and spectrophotometric analysis. Turkish Journal of Chemistry, Cilt: 41 - Sayı: 5, 619–629. https://ajindex.com/articles/184574

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...