Journals / Turkish Journal of Chemistry / 2019 / Cilt: 43 - Sayı: 3

Determination of N-acetylcysteine in the presence of ciprofloxacin or levofloxacin in microparticulate dry powder inhalers

Pages
846–856
Publication Date
2019-06-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

All these outcomes demonstrate that the validated HPLC method is appropriate for simultaneous analysis of CP, LV, and NAC in samples for content uniformity of dry powder inhaler and permeability studies.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A fast and easy method was validated for simultaneous determination of ciprofloxacin hydrochloride monohydrate (CP), levofloxacin hemihydrate (LV), and N-acetylcysteine (NAC) in samples.
📊
Key Findings & Data:The analysis was performed on a C$_{18}$ column (250 x 4.6 mm, 5 μm) (Inertsil ODS-3V) using an isocratic elution method with a mobile phase composed of 25 mM KH$_{2}$PO$_{4}$ (pH 3.0) and methanol (72:28, v/v) at a flow rate of 1 mL/min.
💡
Conclusion & Impact:All these outcomes demonstrate that the validated HPLC method is appropriate for simultaneous analysis of CP, LV, and NAC in samples for content uniformity of dry powder inhaler and permeability studies.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Ciprofloxacin · levofloxacin · N-acetylcysteine

Abstract

A fast and easy method was validated for simultaneous determination of ciprofloxacin hydrochloride monohydrate (CP), levofloxacin hemihydrate (LV), and N-acetylcysteine (NAC) in samples. The analysis was performed on a C$_{18}$ column (250 x 4.6 mm, 5 μm) (Inertsil ODS-3V) using an isocratic elution method with a mobile phase composed of 25 mM KH$_{2}$PO$_{4}$ (pH 3.0) and methanol (72:28, v/v) at a flow rate of 1 mL/min. UV detection was performed at 214 nm for NAC and 293 nm for CP and LV. The method was validated for linearity, accuracy, precision (repeatability and reproducibility), specificity, sensitivity, and stability. The calibration study using several media demonstrated that the calibration curves were linear for all compounds in all media (R$^{2}$ > 0.9993). The limit of detection was 0.098 μg/mL for CP, 0.049 μg/mL for LV, and 0.487 μg/mL for NAC. The limit of quantification was 0.328 μg/mL for CP, 0.165 μg/mL for LV, and 1.624 μg/mL for NAC. Precision and accuracy values of the method fulfilled the required limits. All these outcomes demonstrate that the validated HPLC method is appropriate for simultaneous analysis of CP, LV, and NAC in samples for content uniformity of dry powder inhaler and permeability studies.

🔖

Cite This Article

AKDAĞ, Y., ŞAHİN, S., NEMUTLU, E., ÖNER, L. (2019). Determination of N-acetylcysteine in the presence of ciprofloxacin or levofloxacin in microparticulate dry powder inhalers. Turkish Journal of Chemistry, Cilt: 43 - Sayı: 3, 846–856. https://ajindex.com/articles/184300

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...