Journals / Turkish Journal of Chemistry / 2019 / Cilt: 43 - Sayı: 5

Ionic liquid-based graphene oxide-coated fiber for headspace-solid phase microextraction of polycyclic aromatic hydrocarbons in water samples

Pages
1383–1397
Publication Date
2019-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The recoveries for 8 PAHs using the novel and commercial fibers in tap and seawater samples were obtained very close to each other and were in the range of 75.4% to 116.0%.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Ionic liquid (IL) containing amino and vinyl terminated imidazolium cation and bis[(trifluoromethyl)sulfonyl] imide anion-functionalized graphene oxide (GO) coating material was prepared and coated on a stainless steel wire by a sol-gel technique for headspace-solid phase microextraction (HS-SPME).
📊
Key Findings & Data:Its extraction performance was checked by HS-SPME of polycyclic aromatic hydrocarbons (PAHs) coupled to gas chromatography with mass spectrometry (GC-MS).
💡
Conclusion & Impact:The recoveries for 8 PAHs using the novel and commercial fibers in tap and seawater samples were obtained very close to each other and were in the range of 75.4% to 116.0%.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Graphene oxide · ionic liquid · SPME

Abstract

Ionic liquid (IL) containing amino and vinyl terminated imidazolium cation and bis[(trifluoromethyl)sulfonyl] imide anion-functionalized graphene oxide (GO) coating material was prepared and coated on a stainless steel wire by a sol-gel technique for headspace-solid phase microextraction (HS-SPME). Its extraction performance was checked by HS-SPME of polycyclic aromatic hydrocarbons (PAHs) coupled to gas chromatography with mass spectrometry (GC-MS). The extraction capability of the IL-functionalized GO-coated fiber was comparable with that of the commercial fibers of polydimethylsiloxane (PDMS) and polydimethylsiloxane/carboxen/divinylbenzene (PDMS/CAR/DVB). Under the optimized conditions, such as extraction temperature, extraction time, and salting-out, the proposed HS-SPME-GC-MS method presented a wide working range from 0.003 to 40 $\mu $g L$^{-1\, }$with a correlation coefficient higher than 0.996, low detection limits from 1 to 5 ng L$^{-1}$, and good precision less than 7%. The fiber-to-fiber repeatability was in the range of 0.2%-6.9%. The recoveries for 8 PAHs using the novel and commercial fibers in tap and seawater samples were obtained very close to each other and were in the range of 75.4% to 116.0%.

🔖

Cite This Article

ERDEM, P., TASHAKKORI, P., MERDİVAN, M., BOZKURT, S. S. (2019). Ionic liquid-based graphene oxide-coated fiber for headspace-solid phase microextraction of polycyclic aromatic hydrocarbons in water samples. Turkish Journal of Chemistry, Cilt: 43 - Sayı: 5, 1383–1397. https://ajindex.com/articles/184247

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...