Journals / Turkish Journal of Chemistry / 2019 / Cilt: 43 - Sayı: 5

Magnetic solid-phase extraction based on Coriolus versicolor-immobilized $\gamma $-Fe$_{2}$O$_{3}$ nanoparticles for preconcentration and determination of Al(III) in water and food samples

Pages
1217–1228
Publication Date
2019-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Al(III) was preconcentrated in different water and food samples after successful results were achieved in the case of certified reference samples.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Öz A method for preconcentration of Al(III) prior to its determination by inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed because the sensitivity of ICP-OES is insufficient for trace-level measurement of Al(III).
📊
Key Findings & Data:The method is based on the use of Coriolus versicolor}-immobilized $\gamma $-Fe$_{2}$O$_{3}$ magnetic nanoparticles as a solid phase sorbent.
💡
Conclusion & Impact:Al(III) was preconcentrated in different water and food samples after successful results were achieved in the case of certified reference samples.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Anahtar Kelimeler Aluminum · food · preconcentration

Özet

Öz A method for preconcentration of Al(III) prior to its determination by inductively coupled plasma-optical emission spectrometry (ICP-OES) was developed because the sensitivity of ICP-OES is insufficient for trace-level measurement of Al(III). The method is based on the use of Coriolus versicolor}-immobilized $\gamma $-Fe$_{2}$O$_{3}$ magnetic nanoparticles as a solid phase sorbent. The best experimental conditions were found as pH 6.0, 2.0 mL/min flow rate, 100 mg amount of C. versicoloron 150 mg of $\gamma $-Fe$_{2}$O$_{3}$ nanoparticles, and 500 mL of sample volume. The Al(III) absorbed on biosorbent was eluted with 5.0 mL of 1.0 mol/L HCl. Limit of detection, limit of quantitation, linear range, correlation coefficient, relative standard deviation, and preconcentration factor were achieved as 0.03 ng/mL, 0.11 ng/mL, 0.2 to 20 ng/mL, 0.9994, 3%, and 100, respectively. Al(III) was preconcentrated in different water and food samples after successful results were achieved in the case of certified reference samples.

🔖

Cite This Article

ÖZDEMİR, S., YALÇIN, M. S., KILINÇ, E., SOYLAK, M. (2019). Magnetic solid-phase extraction based on Coriolus versicolor-immobilized $\gamma $-Fe$_{2}$O$_{3}$ nanoparticles for preconcentration and determination of Al(III) in water and food samples. Turkish Journal of Chemistry, Cilt: 43 - Sayı: 5, 1217–1228. https://ajindex.com/articles/184240

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...