Journals / Haydarpaşa Numune Medical Journal / 2019 / Cilt: 59 - Sayı: 1

Comparison of Physical Examination and Simultaneous Ultrasonography Results in Patient in whom Thyroid Gland Nodule was Diagnosed on Scintigraphy Previously and Referred to General Surgery Clinics

Pages
67–70
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

US should be used combined with a careful PE.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Introduction: The first step in diagnosis of thyroid nodules is physical examination (PE). <5% of the adult population has palpable nodules.
📊
Key Findings & Data:However, ultrasound (US) studies revealed higher thyroid nodule prevalence. 1–3% of the nodules have malignancy risk and proper and trusted methods of diagnosis and follow-up are necessary.
💡
Conclusion & Impact:US should be used combined with a careful PE.
🔬Design:Research Article
📍Scope:2002 Verileri
⚙️Variables:Domain Parameters

Özet

Introduction: The first step in diagnosis of thyroid nodules is physical examination (PE). <5% of the adult population has palpable nodules. However, ultrasound (US) studies revealed higher thyroid nodule prevalence. 1–3% of the nodules have malignancy risk and proper and trusted methods of diagnosis and follow-up are necessary. We compared nodules found on PE and US in terms of number and localization. Methods: The data of 42 patients in whom thyroid nodules were diagnosed on scintigraphy, and US and PE were done at the same time between October 2002 and 2003 was analyzed retrospectively. The numbers of nodules detected on PE and US were compared. The nodules located in a different position on PE compared to that of US were accepted false positive. The nodules which were not detected on PE but on US were accepted false-negative results of PE. Mann–Whitney U-test was used for statistical analysis. True positivity on PE was considered equal to the true negativity, and sensitivity, specificity, and accuracy were calculated. Results: PE detected 62 nodules in 42 patients (the mean: 1.47 and standard deviation [SD]: 0.63, for each patient). US detected 73 nodules (the mean: 1.73 and SD: 0.76). The sensitivity, specificity, and accuracy of PE were calculated 51.02%, 65.38, and 51.02, respectively. Discussion and Conclusion: Having a low specificity and sensitivity compared to thyroid US, PE is not reliable on diagnosis and follow-up of thyroid nodules. US should be used combined with a careful PE.

🔖

Cite This Article

SUNAMAK, O., DÜREN, M. (2019). Comparison of Physical Examination and Simultaneous Ultrasonography Results in Patient in whom Thyroid Gland Nodule was Diagnosed on Scintigraphy Previously and Referred to General Surgery Clinics. Haydarpaşa Numune Medical Journal, Cilt: 59 - Sayı: 1, 67–70. https://ajindex.com/articles/167197

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Vander JB, Gaston EA, Dawber TR. The significance of nontoxic thyroid nodules. Final report of a 15-year study of the incidence of thyroid malignancy. Ann Intern Med 1968;69:537– 40. [CrossRef ] 2. Belfiore A, La Rosa GL, Padova G, Sava L, Ippolito O, Vigneri R. The frequency of cold thyroid nodules and thyroid malignancies in patients from an iodine-deficient area. Cancer 1987;60:3096–102. [CrossRef ] 3. Tomimori E, Pedrinola F, Cavaliere H, Knobel M, Medeiros- Neto G. Prevalence of incidental thyroid disease in a relatively low iodine intakearea. Thyroid 1995;5:273–6. [CrossRef ] 4. Lawrence W Jr, Kaplan BJ. Diagnosis and management of patients with thyroid nodules. J Surg Oncol 2002;80:157–70. 5. Salabè GB. Pathogenesis of thyroid nodules: histological classification? Biomed Pharmacother 2001;55:39–53. [CrossRef ] 6. Wiest PW, Hartshorne MF, Inskip PD, Crooks LA, Vela BS, Telepak RJ, et al. Thyroid palpation versus high-resolution thyroid ultrasonography in the detection of nodules. J Ultrasound Med 1998;17:487–96. [CrossRef ] 7. Wong CK, Wheeler MH. Thyroid nodules: rational management. World J Surg 2000;24:934–41. [CrossRef ] 8. Kusic Z, Ratcliffe GE, Maisey MN, Saunders AJ. An assessment of the potential role of routine radionuclide thyroid scanning in the differentiation between solid and cystic lesions in the solitary thyroid nodule. Eur J Nucl Med 1983;8:321–4. [CrossRef ] 9. Walsh RM, Watkinson JC, Franklyn J. The management of the solitary thyroid nodule: a review. Clin Otolaryngol Allied Sci 1999;24:388–97. [CrossRef ] 10. Ashcraft MW, Van Herle AJ. Management of thyroid nodules. II: Scanning techniques, thyroid suppressive therapy, and fine needle aspiration. Head Neck Surg 1981;3:297–322. [CrossRef ] 11. Mazzaferri EL. Management of a solitary thyroid nodule. N Engl J Med 1993;328:553–9. [CrossRef ] 12. Güney G, Şahiner İT. Malignancy Rates of Thyroid Cyto logy: Cyst Fluid Benign or Non-Diagnostic? Med Sci Monit 2017;23:3556–61. [CrossRef ] 13. Middleton WD, Teefey SA, Reading CC, Langer JE, Beland MD, Szabunio MM, et al. Multiinstitutional Analysis of Thyroid Nodule Risk Stratification Using the American College of Radiology Thyroid Imaging Reporting and Data System. AJR Am J Roentgenol 2017;208:1331–41. [CrossRef ] 14. Vargas-Uricoechea H, Meza-Cabrera I, Herrera-Chaparro J. Concordance between the TIRADS ultrasound criteria and the BETHESDA cytology criteria on the nontoxic thyroid nodule.Thyroid Res. 2017 Feb 2;10:1. [CrossRef ] 15. Me