EXPERIMENTAL INVESTIGATION OF SLINKY GROUND HEAT EXCHANGER GROUND SOURCE HEAT PUMP

SLINKY TOPRAK ISI DE?I?TIRGEÇLI TOPRAK KAYNAKLI ISI POMPASININ DENEYSEL OLARAK ARA?TIRILMASI

Pages
37–47
Publication Date
2011-04-01
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Thus, the performance of the operated system has been calculated.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In present study, the test room of 12 m2 floor area has been heated by ground source heat pumps under Elazy? climate conditions.
📊
Key Findings & Data:In order to lay the slinky ground heat exchanger pipe, a ditches with width of 1 m, depth of 2 m and length of 15 m have been excavated.
💡
Conclusion & Impact:Thus, the performance of the operated system has been calculated.
🔬Design:Makale
📍Scope:Comprehensive Sample
⚙️Variables:Toprak Kaynakly Isy Pompasy · Toprak Isy De?i?tirgeci · Slinky

Abstract

In present study, the test room of 12 m2 floor area has been heated by ground source heat pumps under Elazy? climate conditions. In order to lay the slinky ground heat exchanger pipe, a ditches with width of 1 m, depth of 2 m and length of 15 m have been excavated. The slinky pipe have been laid horizontally in the ditch and the water-antifreeze mixture has been circulated through the horizontal slinky ground heat exchanger by the circulation pump. The heat absorbed from the ground has been conveyed to the area to be heated through the heat pump. Thus, the performance of the operated system has been calculated.

Özet

Bu çaly?mada 12 m2 alanyndaki deney odasy Elazy? ?artlarynda toprak kaynakly ysy pompasy ile ysytylmy?tyr. Slinky toprak ysy de?i?tirgeci borularyny yerle?tirebilmek için 1 m eninde, 2 m derinli?inde ve 15 m uzunlu?unda çukur kazylmy?tyr. Slinky borular çukur içine yatay olarak yerle?tirilerek sirkülasyon pompasyyla su-antifriz kary?ymy yatay slinky toprak ysy de?i?tirgeci içinde dola?tyrylmy?tyr. Topraktan çekilen ysy, ysy pompasy vasytasyyla ysytylacak ortama atylmy?tyr. Böylece çaly?tyrylan sistemin performansy hesaplanmy?tyr.

🔖

Cite This Article

Özsolak, O., Esen, M. (2011). EXPERIMENTAL INVESTIGATION OF SLINKY GROUND HEAT EXCHANGER GROUND SOURCE HEAT PUMP. Technological Applied Sciences, Cilt: 6 Sayı: 3, 37–47. https://doi.org/10.12739/10.12739