Prediction of optimum sampling rates of air quality monitoring stations using hierarchical fuzzy logic control system

Pages
1931–1943
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The analysis of the results showed that the sampling rate had a positive correlation with the concentration of the pollutants and the permissible thresholds.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Air quality monitoring systems are being developed and optimized continuously through different methods, and emerging technologies in computational software and simulations have provided efficient and promising results.
📊
Key Findings & Data:Researches showed that adaptive sampling rate can be a solution to save energy and memory space by turning on sampling module during sensing different events.
💡
Conclusion & Impact:The analysis of the results showed that the sampling rate had a positive correlation with the concentration of the pollutants and the permissible thresholds.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Air quality monitoring systems are being developed and optimized continuously through different methods, and emerging technologies in computational software and simulations have provided efficient and promising results. The process of air quality monitoring requires taking air samples, and data sampling can consume energy, produce a redundant traffic load on the communication channel, and memory space in monitoring station electronic control units. Researches showed that adaptive sampling rate can be a solution to save energy and memory space by turning on sampling module during sensing different events. Therefore, the purpose of this paper was to predict the optimum sampling rates of air quality monitoring stations without compromising data accuracy. For this aim, a hierarchical fuzzy logic control system (simulated in MATLAB®/Simulink) was proposed based on contextual conditions including meteorological data of the country and measured concentrations of air pollutants such as carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), and ozone (O3). The analysis of the results showed that the sampling rate had a positive correlation with the concentration of the pollutants and the permissible thresholds. Also, the meteorological factors had a lower influence in determining the sampling rate compared to the concentrations of air pollutants.

🔖

Cite This Article

ABDUL-WAHAB, S. A., CHARABİ, Y., OSMAN, S., YETİLMEZSOY, K., OSMAN, I. İ. (2019). Prediction of optimum sampling rates of air quality monitoring stations using hierarchical fuzzy logic control system. Atmospheric Pollution Research, Cilt: 10 - Sayı: 6, 1931–1943. https://ajindex.com/articles/165079

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Al‐Adwani, S., Elkamel, A., Duever, T.A., Yetilmezsoy, K., Abdul‐Wahab, S.A., 2015. A surrogate‐based optimization methodology for the optimal design of an air quality monitoring network. Can. J. Chem. Eng. 93, 1176–1187.
  2. Abdul-Wahab, S.A., 2003. Analysis of thermal inversions in the khareef salalah region in the sultanate of Oman. J. Geophys. Res. Atmos. 108, 1–8.
  3. Abdul-Wahab, S.A., 2004. An application and evaluation of the CAL3QHC model for predicting carbon monoxide concentrations from motor vehicles near a roadway intersection in Muscat, Oman. Environ. Manag. 34, 372–382.
  4. Abdul-Wahab, S.A., Bakheit, C.S., Siddiqui, R.A., 2005. Study the relationship between the health effects and characterization of thermal inversions in the Sultanate of Oman. Atmos. Environ. 39, 5466–5471.
  5. Abdul-Wahab, S.A., Obaid, J., Elkamel, A., 2014. Modelling of greenhouse gas emissions from the steady state and non-steady state operations of a combined cycle power plant located in Ontario, Canada. Fuel 136, 103–112.
  6. Ahsan, N., Scheding, S., Monteiro, S.T., Leung, R., McHugh, C., Robinson, D., 2015. Adaptive sampling applied to blast-hole drilling in surface mining. Int. J. Rock Mech. Min. Sci. 75, 244–255.
  7. Al-Hoqani, N., Yang, S.H., 2015. Adaptive sampling for wireless household water consumption monitoring. Procedia Eng. 119, 1356–1365.
  8. Alnahdi, A., 2015. Economical and Environmental Impacts of Emission Mitigation in Petroleum Refineries. M.Sc. Thesis. Department of Chemical Engineering, University of Waterloo, Waterloo, Ontario, Canada, pp. 113. Benis, K.Z., Fatehifar, E., Ahmadi, J., Rouhi, A., 2015. Optimal design of air quality monitoring network and its application in an oil refinery plant: an approach to keep health status of workers. Health Promot. Perspect. 5, 269–279.
  9. Benis, K.Z., Fatehifar, E., Shafiei, S., Nahr, F.K., Purfarhadi, Y., 2016. Design of a sensitive air quality monitoring network using an integrated optimization approach. Stoch. Environ. Res. Risk Assess. 30, 779–793.
  10. Bulutsuz, A.G., Yetilmezsoy, K., Durakbasa, N., 2015. Application of fuzzy logic methodology for predicting dynamic measurement errors related to process parameters of coordinate measuring machines. J. Intell. Fuzzy Syst. 29, 1619–1633.
  11. Cai, M., Yin, Y., Xie, M., 2009. Prediction of hourly air pollutant concentrations near urban arterials using artificial neural network approach. Transp. Res. D Transp. Environ. 14, 32–41.
  12. Chatterjee, S., Deering, C.D., Waite, G.P., Prandi, C., Lin, P., 2019