Journals / Acta Orthopaedica et Traumatologica Turcica / 2017 / Cilt: 51 - Sayı: 6

Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration

Pages
448–450
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Ultrasonography is a reliable and effective procedure fordetection of dorsal screw penetrations.Level of evidence: Level III, Diagnostic study.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study was to compare the efŞciency of dorsal tangential fluoroscopy and ultrasonography in detecting dorsal screw penetration in distal radius volar locking plate applications.Methods: Ten cadaveric forearms were operated.
📊
Key Findings & Data:The distal four screws were protruded 0, 1 and 2 mminto each of the second, third and fourth dorsal compartments of distal radius.
💡
Conclusion & Impact:Ultrasonography is a reliable and effective procedure fordetection of dorsal screw penetrations.Level of evidence: Level III, Diagnostic study.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this study was to compare the efŞciency of dorsal tangential fluoroscopy and ultrasonography in detecting dorsal screw penetration in distal radius volar locking plate applications.Methods: Ten cadaveric forearms were operated. The distal four screws were protruded 0, 1 and 2 mminto each of the second, third and fourth dorsal compartments of distal radius. Dorsal horizon views weretaken usingfluoroscopy. Each radiographic image was evaluated by two orthopedic surgeons who areblinded to procedure. Sonographic evaluations were performed by an orthopedic surgeon blinded to theprocedure. Both dorsal horizon view and ultrasonography assessments were noted by the evaluatorswhether the tip of the screw penetrated or not the dorsal cortex for each compartment.Results: No signiŞcant difference was observed on correct detection of 0 mm, 1 mm and 2 mm screwpenetrations at second and third compartments. In the fourth compartment, there was no differencewith 0 mm and 2 mm penetrations but correct detection accuracy of 1 mm screw penetration was 87% inultrasonography group and 71% in dorsal horizon view group.Conclusions: The accuracy of ultrasonography on 1 mm penetration at the fourth compartment is betterthan dorsal horizon view. However, dorsal horizon view and ultrasonography accuracy is similar for theother compartments and penetration levels. Ultrasonography is a reliable and effective procedure fordetection of dorsal screw penetrations.Level of evidence: Level III, Diagnostic study.

🔖

Cite This Article

GURBUZA, Y., KÜÇÜK, L., GÜNAY, H., ÖZAKSAR, K., SÜGÜN, T. S., BİLGE, O. (2017). Comparison of ultrasound and dorsal horizon radiographic view for the detection of dorsal screw penetration. Acta Orthopaedica et Traumatologica Turcica, Cilt: 51 - Sayı: 6, 448–450. https://ajindex.com/articles/165056

References (14)

  1. Hall SE, Criddle RA, Comito TL, Prince RL. A case-control study of quality of life and functional impairment in women with long-standing vertebral osteoporotic fracture. Osteoporos Int J Establ Res Coop Bet Eur Found Osteoporos Natl Osteoporos Found USA. 1999;9:508e515
  2. Sambrook P, Cooper C. Osteoporosis. Lancet (London, England). 2006;367: 2010e2018
  3. Phillips FM. Minimally invasive treatments of osteoporotic vertebral compression fractures. Spine. 2003;28:S45eS53
  4. Johnell O, Kanis JA, Oden A, et al. Mortality after osteoporotic fractures. Osteoporos Int J Establ Res Coop Bet Eur Found Osteoporos Natl Osteoporos Found USA. 2004;15:38e42
  5. Kanis JA, Pitt FA. Epidemiology of osteoporosis. Bone. 1992;13:S7eS15
  6. Ploeg WT, Veldhuizen AG, The B, Sietsma MS. Percutaneous vertebroplasty as a treatment for osteoporotic vertebral compression fractures: a systematic review. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deformity Soc Eur Sect Cerv Spine Res Soc. 2006;15:1749e1758
  7. Mudano AS, Bian J, Cope JU, et al. Vertebroplasty and kyphoplasty are associated with an increased risk of secondary vertebral compression fractures: a population-based cohort study. Osteoporos Int J Establ Res Coop Bet Eur Found Osteoporos Natl Osteoporos Found USA. 2009;20:819e826
  8. Boger A, Heini P, Windolf M, Schneider E. Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deformity Soc Eur Sect Cerv Spine Res Soc. 2007;16:2118e2125
  9. Trout AT, Kallmes DF, Kaufmann TJ. New fractures after vertebroplasty: adjacent fractures occur significantly sooner. AJNR Am J Neuroradiol. 2006;27: 217e223
  10. Voormolen MH, Lohle PN, Juttmann JR, van der Graaf Y, Fransen H, Lampmann LE. The risk of new osteoporotic vertebral compression fractures in the year after percutaneous vertebroplasty. J Vasc Interv Radiol JVIR. 2006;17: 71e76
  11. Tseng YY, Yang TC, Tu PH, Lo YL, Yang ST. Repeated and multiple new vertebral compression fractures after percutaneous transpedicular vertebroplasty. Spine. 2009;34:1917e1922
  12. Ledlie JT, Renfro MB. Kyphoplasty treatment of vertebral fractures: 2-year outcomes show sustained benefits. Spine. 2006;31:57e64
  13. Uppin AA, Hirsch JA, Centenera LV, Pfiefer BA, Pazianos AG, Choi IS. Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis. Radiology. 2003;226:119e124
  14. Fribourg D, Tang C, Sra P, Delamarte