Journals / International Journal of Medical Biochemistry / 2018 / Cilt: 1 - Sayı: 2

An evaluation of efficiency in an emergency laboratory by turnaround time

Pages
57–61
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additionally, evaluation of TAT should be taken into consideration in the routine workflow of laboratories.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: Accuracy, precision, timeliness, and authenticity are the 4 pillars of efficient laboratory services.
📊
Key Findings & Data:However, turnaround time (TAT) is usually regarded by clinicians as the benchmark of laboratory performance.
💡
Conclusion & Impact:Additionally, evaluation of TAT should be taken into consideration in the routine workflow of laboratories.
🔬Design:Research Article
📍Scope:2016 · 286,577 samples
⚙️Variables:Domain Parameters

Özet

Objectives: Accuracy, precision, timeliness, and authenticity are the 4 pillars of efficient laboratory services. Clinical biochemists generally overlook timeliness as an important attribute. However, turnaround time (TAT) is usually regarded by clinicians as the benchmark of laboratory performance. TAT can be classified by tests: priority, population served, etc. The aim of the current study was to both evaluate and compare the TAT of the test panels used in the emergency laboratory of Ankara Numune Training and Research Hospital. Methods: The TAT for tests carried out in the emergency laboratory in 2016 was recorded. The TAT limit for each analyte was determined by the hospital’s quality control department. Routine biochemistry, arterial blood gas, troponin, erythrocyte sedimentation rate, complete blood count, beta-human chorionic gonadotropin, coagulation panel, and urinalysis tests were evaluated. Samples were grouped by admission time, day, and staff on duty. Samples that exceeded the TAT limit were determined and compared in terms of sample receipt time, day, and staffing. Statistical analysis was performed using SPSS for Windows, Version 15.0 (SPSS Inc., Chicago, IL, USA). P<0.05 was considered statistically significant. Results: A total of 286,577 samples were analyzed in 2016 in this laboratory. The TAT of 30,129 samples exceeded the established time limit. The mean TAT of the staff who worked a day shift on weekdays was significantly higher than that of other shifts, with the exception of arterial blood gas (ABG) testing (p=0.000 for all panels). The mean TAT of the staff who worked a night shift on weekdays and weekends was statistically different, excluding coagulation (p=0.08) and ABG (p=0.09) tests. Conclusion: It is strongly recommended that all of the staff who work in the laboratory be sufficiently informed and educated about TAT. Additionally, evaluation of TAT should be taken into consideration in the routine workflow of laboratories.

🔖

Cite This Article

KİLİNCKAYA, M. F., YÜCEL, Ç., TURHAN, T. (2018). An evaluation of efficiency in an emergency laboratory by turnaround time. International Journal of Medical Biochemistry, Cilt: 1 - Sayı: 2, 57–61. https://ajindex.com/articles/164811

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Bergman B, KlefsjO, B. Quality: FromCustomer Needs to Customer Satisfaction. London: McGraw-Hill; 1994
  2. Hawkins RC. Laboratory turnaround time. Clin Biochem Rev 2007;28:179–94
  3. Neuberger J, Peters M. The clinical interface-a British physician's view. Clin Chim Acta 1996;248:11–8
  4. Lundberg GD. Acting on significant laboratory results. JAMA 1981;245:1762–3
  5. Crook MA. Near patient testing and pathology in the new millennium. J Clin Pathol 2000;53:27–30
  6. Steindel SJ, Howanitz PJ. Physician satisfaction and emergency department laboratory test turnaround time. Arch Pathol Lab Med 2001;125:863–71
  7. Howanitz PJ, Cembrowski GS, Steindel SJ, Long TA. Physician goals and laboratory test turnaround times. A College of American Pathologists Q-Probes study of 2763 clinicians and 722 institutions. Arch Pathol Lab Med 1993;117:22–8
  8. Novis DA, Jones BA, Dale JC, Walsh MK. College of American Pathologists. Biochemical markers of myocardial injury test turnaround time: a College of American Pathologists Q-Probes study of 7020 troponin and 4368 creatine kinase-MB determinations in 159 institutions. Arch Pathol Lab Med 2004;128:158–64
  9. Lu Y, Leong W, Wei B, Yu P, Wang C, Ying Y, et al. An Evaluation of Laboratory Efficiency in Shanghai Emergency by Turn Around Times Level. J Clin Lab Anal 2015;29:334–41
  10. Chien TI, Lu JY, Kao JT, Cheng YC, Lee YF. Evaluation and improvement strategy of analytical turnaround time in the stat laboratory. J Formos Med Assoc 2007;106:558–64
  11. Valenstein P. Laboratory turnaround time. Am J Clin Pathol 1996;105:676–88
  12. Barnett RN, Bimmell M. Peracca M, Rosemann K. Time intervals between ordering and obtaining laboratory test results. Patholo- gist 1975;29:3–8
  13. Valenstein P, Leiken A, Lehmann C. Test-ordering by multiple physicians increases unnecessary laboratory examinations. Arch Pathol Lab Med 1988;112:238–41
  14. Cheng P, Rieta R, Bowen RAR. Evaluation of turn-around-time (TAT) of emergency department specimens after computerized autoverification. Clin Biochem. 2008;41:1265 15. Goswami B, Singh B, Chawla R, Gupta VK, Mallika V. Turn Around Time (TAT) as a Benchmark of Laboratory Performance. Indian J Clin Biochem 2010;25:376–9
  15. Groenewald AJ, Potgieter HD. Physician satisfaction and emergency (stat) laboratory turnaround time during various developmental stages. Med Technol 2014;28:20–5.