Journals / Sakarya University Journal of Science / 2026 / Volume: 23 Issue: 1

Assesment of Power Quality Disturbances For Grid Integration of PV Power Plants

Gökay Bayrak(Bursa Teknik Üniversitesi)0000-0002-5136-0829
Alper Yılmaz(Bursa Teknik Üniversitesi)0000-0003-3736-3668
Pages
—
Publication Date
2019-02-01
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Another advantage of the realized study is that the developed model can be used to measure the performance of the PV connected distributed generation system in fault detection and classification studies.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Power Quality problems, which have become an important consumer issue in recent years, are defined as changes in voltage, current, or frequency in the power system.
📊
Key Findings & Data:Also, the integration of PV power plants to the main grid will cause several power quality problems, and a reliable operation of the grid with PV power plants is a significant issue for distributed generation.
💡
Conclusion & Impact:Another advantage of the realized study is that the developed model can be used to measure the performance of the PV connected distributed generation system in fault detection and classification studies.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Distributed Generation · Power Quality Disturbances · Grid Connected PV Systems

Abstract

Power Quality problems, which have become an important consumer issue in recent years, are defined as changes in voltage, current, or frequency in the power system. Among the factors affecting energy quality in grid-connected PV systems are island mode operation, current and voltage harmonics, transients, flicker, interruption, DC offset, notches, frequency changes, voltage sag / swell, voltage imbalances in the system and power factor. Because of the power quality problems, several transmission and distribution losses can occur due to both the consumers and the generators. Also, the integration of PV power plants to the main grid will cause several power quality problems, and a reliable operation of the grid with PV power plants is a significant issue for distributed generation. Thus, the first step in preparing a reliable algorithm for detecting power quality events occurring in the current grid is to model a power system in which power quality impairments can be analyzed. In this work, the power quality disturbances that occur in the low-voltage grid that is fed through both the main grid and the grid-connected PV system are modeled and investigated. Developed electric power distribution model includes simulation of voltage sags caused by three phase fault, transformer energization and asynchronous motor switching, voltage swells caused by three phase fault, transients due to large capacitor bank switching, harmonics and notches caused by the load connected via the power converter. Examination of the power quality disturbances with simulation clearly revealed the resulting waveforms, the response of the electrical power system to the fault conditions. Another advantage of the realized study is that the developed model can be used to measure the performance of the PV connected distributed generation system in fault detection and classification studies.

🔖

Cite This Article

Bayrak, G., Yılmaz, A. (2019). Assesment of Power Quality Disturbances For Grid Integration of PV Power Plants. Sakarya University Journal of Science, Volume: 23 Issue: 1. https://doi.org/10.16984/saufenbilder.407323

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (21)

  1. Dugan, R.C., Mcgranaghan, M.F. Santoso, S. and Beaty, H.W., 2002. Electrical power systems quality, McGraw-Hill, New York.
  2. Bollen, M.H.J. and Gu, I.Y.H., 2006, Signal processing of power quality disturbances, John Wiley&Sons, New York.
  3. Khokhar, S., Zin, A. M., Mokhtar, A. S., & Ismail, N. A. M. (2014, October). MATLAB/Simulink based modeling and simulation of power quality disturbances. In Energy Conversion (CENCON), 2014 IEEE Conference on (pp. 445-450). IEEE.
  4. Haykin, S. 2008. “Neural networks and learning machines”, Pearson, 3rd edition.
  5. Burges, C J.C. 1998. “A tutorial on support vector machines for pattern recognition”, Data Mining and Knowledge Discovery, 2, 121-167.
  6. Silva, K.M., Souza, B.A., Brito, N.S.D. 2006. “Fault detection and classification in transmission lines based on wavelet transform and ANN”, IEEE Trans Power Deliv, 21, 2058–63.
  7. Dash, P.K., Samantaray, S.R., Panda, G. 2007. “Fault classification and section identification of an advanced series-compensated transmission line using support vector machine”, IEEE Trans Power Deliv, 22, 67–73.
  8. Valtierra-Rodriguez, M., de Jesus Romero-Troncoso, R., Osornio-Rios, R. A., & Garcia-Perez, A. (2014). Detection and classification of single and combined power quality disturbances using neural networks. IEEE Transactions on Industrial Electronics, 61(5), 2473-2482.
  9. Rodriguez-Guerrero, M. A., Carranza-Lopez-Padilla, R., Osornio-Rios, R. A., & Romero-Troncoso, R. D. J. (2017). A novel methodology for modeling waveforms for power quality disturbance analysis. Electric Power Systems Research, 143, 14-24.
  10. Simić, M., Kokolanski, Z., Denić, D., Dimcev, V., Živanović, D., & Taskovski, D. (2017). Design and evaluation of computer-based electrical power quality signal generator. Measurement, 107, 77-88.
  11. Mohanty, S. R., Ray, P. K., Kishor, N., & Panigrahi, B. K. (2013). Classification of disturbances in hybrid DG system using modular PNN and SVM. International Journal of Electrical Power & Energy Systems, 44(1), 764-777.
  12. Zhang, M., Li, K., & Hu, Y. (2011). A real-time classification method of power quality disturbances. Electric power systems Research, 81(2), 660-666.
  13. IEEE Std. 1547, IEEE standard for interconnecting distributed resources with electric power systems, 2015.
  14. IEEE Std 519, IEEE recommended practices and requirements for harmonic control in electrical power systems, 2014.
  15. IEEE Std 1159, IEEE Recommended Practice for Monitoring Electric Power Quality, 2009.
  16. Electromagnetic Compatibility (EMC)- Part 3-3, Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection, IEC 61000-3-3, 2013.
  17. Regina Lamedica, Alberto Prudenzi, Enrico Tironi, Dario Zaninelli – Analysis of Harmonics Distortion Limits in IEC and IEEE Standards – Electrical Power Quality and Utilisation Journal, vol. 5, iss. 2, sept. 1999, pp. 47-52.
  18. M. H. Bollen, Understanding power quality problems vol. 3: IEEE press New York, 2000.
  19. Bayrak. G., Cebeci. M. 2014. Grid connected fuel cell and PV hybrid power generating system design with Matlab Simulink. International Journal of Hydrogen Energy. 39(1):8803-8812.
  20. Bayrak, G., Yilmaz, A., “Design and Performance Assessment of A Grid-Connected PV System for Residential Power Generation”, 7th International 100% Renewable Energy Conference, pp: 62-67,18-20 Mayıs 2017, İstanbul, TURKEY
  21. Bayrak, G., Kabalci, E., “Implementation of a new remote islanding detection method for wind–solar hybrid power plants”, Renewable and Sustainable Energy Reviews, 58:1-15, 2016.