Journals / Turkish Journal of Civil Engineering / 2010 / Cilt: 21 Sayı: 105

Investigation of FRP Strengthening Design Rules for Insufficient RC Columns

Pages
1425–1444
Publication Date
2010-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The first one is compatible with the current code procedure and the other is based on interstory drifts in order to obtain simpler and more economical FRP design in addition to its accuracy.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Increasing the deformation capacities of code-incompliant RC columns by wrapping their potential plastic hinge regions with fiber-reinforced polymer (FRP) has become a rather popular strengthening technique in recent years.
📊
Key Findings & Data:FRP design guidelines are included in the 7th chapter of the Turkish Earthquake Code (TEC-07) that became effective in 2007.
💡
Conclusion & Impact:The first one is compatible with the current code procedure and the other is based on interstory drifts in order to obtain simpler and more economical FRP design in addition to its accuracy.
🔬Design:Araştırma Makalesi
📍Scope:2007 Verileri
⚙️Variables:Columns · flexural behavior · CFRP confinement

Abstract

Increasing the deformation capacities of code-incompliant RC columns by wrapping their potential plastic hinge regions with fiber-reinforced polymer (FRP) has become a rather popular strengthening technique in recent years. FRP design guidelines are included in the 7th chapter of the Turkish Earthquake Code (TEC-07) that became effective in 2007. This study intends to scrutinize the design approach of TEC-07 in light of the test results of 10 columns tested under axial load and cyclic displacement excursions at METU and the test results of 18 columns gathered from literature. After careful investigations, it was clearly seen that in TEC-07, the FRP wrapped column performance limits were over conservative and led to uneconomical designs. Two different design methods were developed. The first one is compatible with the current code procedure and the other is based on interstory drifts in order to obtain simpler and more economical FRP design in addition to its accuracy.

Özet

-

🔖

Cite This Article

Özcan, O., Binici, B., Özcebe, G. (2010). Investigation of FRP Strengthening Design Rules for Insufficient RC Columns. Turkish Journal of Civil Engineering, Cilt: 21 Sayı: 105, 1425–1444. https://ajindex.com/articles/1627311

📄 Full Text PDF Viewer

📄