Journals / Atmospheric Pollution Research / 2019 / Cilt: 10 - Sayı: 3

PM2.5 emission characteristics of coal-fired power plants in Beijing-Tianjin- Hebei region, China

Pages
954–959
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The concentration of Ca, K, Na, Mg and As increased 56.62%, 29.24%, 98.78%, 114.27% and 195.34% in PM2.5 through the WFGD system and others decreased or remained constant.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, six typical coal-fired power plants (CFPPs) in Beijing-Tianjin-Hebei (BTH) region were selected to investigate the emission characteristic of PM2.5.
📊
Key Findings & Data:A 5-stage large flow impact sampler (DGI) was applied to collect PM2.5.
💡
Conclusion & Impact:The concentration of Ca, K, Na, Mg and As increased 56.62%, 29.24%, 98.78%, 114.27% and 195.34% in PM2.5 through the WFGD system and others decreased or remained constant.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

In this study, six typical coal-fired power plants (CFPPs) in Beijing-Tianjin-Hebei (BTH) region were selected to investigate the emission characteristic of PM2.5. A 5-stage large flow impact sampler (DGI) was applied to collect PM2.5. Five parallel samples were collected at the same sampling location and particles were divided into five parts:>2.5 μm、1–2.5 μm、0.5–1 μm、0.2–0.5 μm and 2.5 μm)>c ( c (0.2–0.5 μm)>c (0.5–1 μm)>c (1–2.5 μm). The analysis of element revealed that Si and Al were the main elements in PM2.5 before and after the desulfurization. The concentration of Ca, K, Na, Mg and As increased 56.62%, 29.24%, 98.78%, 114.27% and 195.34% in PM2.5 through the WFGD system and others decreased or remained constant.

🔖

Cite This Article

LİU, S., ZHANG, Z., WANG, Y. J., HU, Y., LİU, W., CHEN, C., MEİ, Y., SUN, H. J. (2019). PM2.5 emission characteristics of coal-fired power plants in Beijing-Tianjin- Hebei region, China. Atmospheric Pollution Research, Cilt: 10 - Sayı: 3, 954–959. https://ajindex.com/articles/161931

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Chen, M., 2010. Analysis of the liquid drips carried by flue gas at the outlet of stack after wet desulfurization. Electr. Power Constr. 31 (10), 80–83.
  2. Du, X., Lu, C., Wang, H., Ma, J.H., 2012. Trends of urban air pollution in Zhengzhou City in 1996–2008. Chin. Geogr. Sci. 22, 402–413.
  3. Hu, B., Liu, Y., Ren, F., Pan, D.P., Yuan, Z.L., YangL, J., 2016. Experimental study on simultaneous control of fine particle and SO3 by low-low temperature electrostatic precipitator. Proc. CSEE 3, 1–7.
  4. Huang, R.J., Zhang, Y.L., Bozzetti, C., Ho, K.F., Cao, J.J., Han, Y.M., Daellenbach, K.R., Slowik, J.G., Platt, S.M., Canonaco, F., Zotter, P., Wolf, R., Pieber, S.M., Bruns, E.A., Crippa, M., Ciarelli, G., Piazzalunga, A., Schwikowski, M., Abbaszade, G., Schnelle- Kreis, J., Zimmermann, R., An, Z.S., Szidat, S., Baltensperger, U., El Haddad, I., Prevot, A.S.H., 2014. High secondary aerosol contribution to particulate pollution during haze events in China. Nature 514, 218–222.
  5. Jiang, J.K., Zhou, W., Cheng, Z., Wang, S.X., He, K.B., Hao, J.M., 2015. Particulate matter distributions in China during a winter period with frequent pollution episodes (January 2013). Aerosol Air Qual. Res. 15, 494–503.
  6. Jing, J.I., Wang, G., Xilong, D.U., Jin, C., Yang, H.L., Liu, J., Yang, Q.L., Josine, T.L., 2013. Evaluation of adsorbing haze PM2.5 fine particulate matters with plants in Beijing- Tianjin-Hebei region in China. Sci. China Earth Sci. 43, 694–699.
  7. Lei, Y., Zhang, Q., He, K.B., Streets, D.G., 2011. Primary anthropogenic aerosol emission trends for China, 1990–2005. Atmos. Chem. Phys. 11, 931–954.
  8. Li, Z., 2013. Research on PM2.5 Production and Emission Characteristics of Thermal Pulverized Coal Fired Power Plant. Doctoral Dissertation of Harbin Institute of Technology, Harbin. Li, Y.X., Liu, J.J., Zhu, N., 2002. The most penetrating particle size in the application of high efficiency filter. Contam. Control Air Conditioning Technol. 4, 23–25.
  9. Li, W., Shi, Z., Zhang, D., Zhang, X., Li, P., Feng, Q., Yuan, Q., Wang, W., 2012. Haze particles over a coal‐burning region in the China Loess Plateau in winter: three flight missions in December 2010. J. Geophys. Res. Atmos. 117, D12. Li, Z., Wang, H.T., Dong, H.M., Li, D., 2015. Experimental study on influence of wet desulphurization on PM2.5 emission of 660 MW pulverized coal fired boiler. Energy Conserv. Technol. 193 (33), 399–404.
  10. Li, Z., Ji, Y., Ma, H., Zhao, P., Zeng, X., Liu, S., Jiang, Y., Wang, L., Liu, A., Gao, H., Liu, F., Mwangi, J.