AI Summary & Key Takeaways
AI InsightThese findings support the long-term cardiac safety of the vaccine in this population.
📌 3 Key Takeaways
Abstract
Introduction: The cardiac safety of BNT162b2 mRNA vaccination has been questioned due to rare reports of vaccine-associated myocarditis, particularly in young individuals. This study aimed to evaluate the long-term effects of BNT162b2 mRNA vaccination on electrocardiographic repolarization parameters and echocardiographic cardiac function in young healthy adults. Methods: This prospective cross-sectional study included 200 healthy individuals aged 18–45 years. Participants who had received two or three doses of BNT162b2 at least two years prior to enrollment were assigned to the vaccinated group (n=112), while unvaccinated individuals constituted the control group (n=88). Standard 12-lead electrocardiography and transthoracic echocardiography were performed. Electrocardiographic repolarization indices and diastolic function parameters were compared between groups. Given the significant sex imbalance, sex-adjusted analyses were performed using analysis of covariance. Results: P-wave dispersion (46.2 ± 6.8 vs. 45.7 ± 7.1 ms, p=0.61), QT dispersion (38.4 ± 8.9 vs. 38.1 ± 9.3 ms, p=0.86), QTc dispersion (44.9 ± 10.3 vs. 46.8 ± 11.2 ms, p=0.27), and frontal QRS–T angle (33.6 ± 25.0 vs. 30.9 ± 12.2°, p=0.78) did not differ significantly between vaccinated and unvaccinated participants. After adjustment for sex, vaccination status was not independently associated with P-wave dispersion (adjusted p=0.333) or QTc dispersion (adjusted p=0.559). Although lateral e′ velocity (13.20 ± 2.40 vs. 12.23 ± 1.57 cm/s, p=0.008) and deceleration time (203.9 ± 25.9 vs. 194.6 ± 17.9 ms, p=0.017) were higher in the vaccinated group, these differences remained within established physiological reference ranges. Left ventricular systolic function (LVEF: 64.3 ± 2.3% vs. 64.6 ± 2.5%, p=0.23) and other diastolic parameters were largely comparable between groups, with all values remaining within normal physiological reference ranges. Conclusion: In young healthy adults evaluated at least two years after vaccination, BNT162b2 mRNA vaccination was not associated with clinically meaningful long-term alterations in cardiac repolarization or diastolic function. These findings support the long-term cardiac safety of the vaccine in this population.
Özet
Giriş: BNT162b2 mRNA COVID-19 aşısının genç ve sağlıklı erişkinlerde kardiyak elektriksel ve mekanik fonksiyonlar üzerindeki etkisi tam olarak bilinmemektedir. Bu çalışma, en az iki doz BNT162b2 aşısı yapılmış bireyler ile hiç aşılanmamış sağlıklı bireylerde elektrokardiyografik repolarizasyon indeksleri ve transtorasik ekokardiyografi parametrelerinin karşılaştırılmasını amaçlamaktadır. Yöntem: Prospektif kesitsel tasarımda yürütülen çalışmaya 18–45 yaş arası 200 gönüllü dahil edildi (112 aşılı, 88 aşısız). Tüm EKG kayıtları Nihon Kohden ECG-1250K cihazı ile, ekokardiyografik incelemeler Philips EPIQ 7 cihazı ile gerçekleştirildi. P dispersiyonu, QT/QTc dispersiyonu ve frontal QRS-T açısı değerlendirildi. Ekokardiyografide LVEF, sol ventrikül çapları, mitral akım parametreleri, doku Doppler (septal/lateral e′), E/e′, IVRT, DT, LA çapı ve TAPSE ölçüldü. Bulgular: Elektrokardiyografik repolarizasyon indeksleri iki grup arasında anlamlı farklılık göstermedi. LVEF her iki grupta da normaldi. Aşılı grupta lateral e′ (p=0.008) ve DT (p=0.017) değerleri istatistiksel olarak daha yüksek saptandı; ancak tüm parametreler fizyolojik normal aralıklar içerisindeydi. Diğer tüm diyastolik fonksiyon göstergeleri benzerdi. Sonuç: BNT162b2 mRNA aşılaması genç sağlıklı bireylerde ventriküler repolarizasyon veya diyastolik fonksiyon üzerinde klinik açıdan anlamlı bir etkilenmeye yol açmamaktadır.