⚡ TL;DR(Too Long; Didn't Read)

Here, to the our best knowledge for the first time in the English literature, this report presents an extremely rare complication of a broken and stuck tip part of aortic stent-graft in the intravascular space and successful removal by using the coaxial technique.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Thoracic aortic endovascular repair (TEVAR) is increasingly preferred as a treatment of choice in thoracic aortic diseases.
📊
Key Findings & Data:Intravascular foreign body is one of the TEVAR-related complications similar to the other endovascular operations.
💡
Conclusion & Impact:Here, to the our best knowledge for the first time in the English literature, this report presents an extremely rare complication of a broken and stuck tip part of aortic stent-graft in the intravascular space and successful removal by using the coaxial technique.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Thoracic aortic endovascular repair (TEVAR) is increasingly preferred as a treatment of choice in thoracic aortic diseases. Intravascular foreign body is one of the TEVAR-related complications similar to the other endovascular operations. Here, to the our best knowledge for the first time in the English literature, this report presents an extremely rare complication of a broken and stuck tip part of aortic stent-graft in the intravascular space and successful removal by using the coaxial technique.

🔖

Cite This Article

CANYİĞİT, M., ATEŞ, Ö. F., SAĞLAM, M. F., HIDIROĞLU, M. (2019). Successful treatment of unexpected complication during aortic stent-grafting: retrieval of broken stent-graft tip by coaxial technique. Diagnostic and Interventional Radiology, Cilt: 25 - Sayı: 2, 169–172. https://ajindex.com/articles/160960

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Nordon IM, Hinchliffe RJ, Loftus IM, Morgan RA, Thompson MM. Management of acute aortic syndrome and chronic aortic dissection. Cardiovasc Interv Radiol 2011; 34:890–902. [CrossRef] 2. Cheng D, Martin J, Shennib H, et al. Endovascular aortic repair versus open surgical repair for descending thoracic aortic disease: a systematic review and meta-analysis of comparative studies. J Am Coll Cardiol 2010; 55:986–1001. [CrossRef] 3. Katsargyris A, Spinelli D, Oikonomou K, Mufty H, Verhoeven EL. Incomplete expansion of chimney stent graft during chimney-thoracic endovascular aneurysm repair. Ann Vasc Surg 2017; 39:293e1–e5. 4. Follis F, Filippone G, Stabile A, et al. Endovascular graft deployment in the false lumen of type B dissection. Interact Cardiovasc Thorac Surg 2010; 10:597–599. [CrossRef] 5. Fanelli F, Gazzetti M, Boatta E, Ruggiero M, Lucatelli P, Speziale F. Acute left arm ischemia associated with floating thrombus in the proximal descending aorta: combined endovascular and surgical therapy. Cardiovasc Interv Radiol 2011; 34:193–197. [CrossRef] 6. Fanelli F, Lucatelli P, Allegritti M, Cannavale A, Wlderk A, Passariello R. Percutaneous endoarterectomy: Unusual complication during thoracic endovascular repair. Clin Radiol 2012; 67:1124–1126. [CrossRef] 7. Egglin T, Dickey KW, Rosenblatt M, Pollak J. Retrieval of intravascular foreign bodies: experience in 32 cases. AJR Am J Roentgenol 1995; 164:1259–1264. [CrossRef] 8. Tateishi M, Tomizawa Y. Intravascular foreign bodies: danger of unretrieved fragmented medical devices. J Artif Organs 2009; 12:80–89. [CrossRef] 9. Mitchell RS, Ishimaru S, Ehrlich MP, et al. First International Summit on Thoracic Aortic Endografting: roundtable on thoracic aortic dissection as an indication for endografting. J Endovasc Ther 2002; 9(Suppl 2):98–105. [CrossRef] 10. Seong CK, Kim YJ, Chung JW, et al. Tubular foreign body or stent: safe retrieval or repositioning using the coaxial snare technique. Korean J Radiol 2002; 3:30–37. [CrossRef] 11. Woodhouse JB, Uberoi R. Techniques for intravascular foreign body retrieval. Cardiovasc Interv Radiol 2013; 36:888–897. [CrossRef] 12. Intagliata E, Basile F, Vecchio R. Totally implantable catheter migration and its percutaneous retrieval: case report and review of the literature. G Chir 2016; 37:211. [CrossRef] 13. Schechter MA, O’Brien PJ, Cox MW. Retrieval of iatrogenic intravascular foreign bodies. J Vasc Surg 2013; 57:276–281. [CrossRef]