Journals / Atmospheric Pollution Research / 2020 / Cilt: 11 - Sayı: 12

A long-term multi-parametric monitoring study: Indoor air quality (IAQ) and the sources of the pollutants, prevalence of sick building syndrome (SBS) symptoms, and respiratory health indicators

Pages
2270–2281
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Performing more studies from the health and IAQ points of view improve public awareness.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Poor indoor air quality (IAQ) can cause several respiratory diseases and symptoms.
📊
Key Findings & Data:In this study, IAQ of 121 homes located in 3 different towns of Çanakkale, Turkey was monitored throughout a year.
💡
Conclusion & Impact:Performing more studies from the health and IAQ points of view improve public awareness.
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Poor indoor air quality (IAQ) can cause several respiratory diseases and symptoms. In this study, IAQ of 121 homes located in 3 different towns of Çanakkale, Turkey was monitored throughout a year. Target air pollutants were particulate matter, volatile organic compounds (VOCs), bioaerosols, and Carbon dioxide (CO2), as well as air temperature and humidity. Moreover, pulmonary functions of the occupants were measured on a monthly basis. Also, occurrence of sick building syndrome (SBS) symptoms and other health related data were gathered from the occupants by a detailed questionnaire. The SBS is a situation related to indoor air pollution in which the occupants of a building experience health or comfort related adverse effects that appear to be associated directly to the time spent in the “sick” building. Results of this study showed that the highest indoor air pollutant levels were observed in Çan town and the lowest levels were observed in Central town. Indoor levels of bioaerosols, particulate matter, benzene, Cladosporium spp., and Penicillium spp. as well as pulmonary functions of the occupants showed statistically significant differences between the locations of the homes (p < 0.001). Factor analysis implied that both indoor and outdoor originated sources contributed to IAQ. Even though the predominant SBS symptoms varied seasonally and spatially among the study sites, fatigue, cold-flu like symptoms, and difficulty in concentration occurred frequently. Correlations were found among the occurrence of SBS symptoms, measured IAQ parameters, and personal factors (p < 0.05). Performing more studies from the health and IAQ points of view improve public awareness.

🔖

Cite This Article

MENTEŞE, S., MİRİCİ, N. A., ELBİR, T., PALAZ, E., MUMCUOĞLU, D. T., ÇOTUKER, O., BAKAR, C., OYMAK, S., OTKUN, M. T. (2020). A long-term multi-parametric monitoring study: Indoor air quality (IAQ) and the sources of the pollutants, prevalence of sick building syndrome (SBS) symptoms, and respiratory health indicators. Atmospheric Pollution Research, Cilt: 11 - Sayı: 12, 2270–2281. https://ajindex.com/articles/160520

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. ACGIH, 1989. American Conference of Governmental Industrial Hygienists Guidelines for the Assessment about Aerosols in the Indoor Environment. ACGIH. Cincinnati, Ohio. Amin, N.D.M., Akasah, Z.A., Razzaly, W., 2015. Architectural evaluation of thermal comfort: sick building syndrome symptoms in engineering education laboratories. Procedia-Soc. Behav. Sci 204, 19–28. ANSI/ASHRAE Standard 62.1, 2016. Ventilation for Acceptable Indoor Air Quality. ASHRAE, Atlanta, GA. ANSI/ASHRAE Standard 62.2, 2016. Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings. ASHRAE, Atlanta, GA. Barnett, H.L., Hunter, B.B., 2003. In: Illustrated Genera of Imperfect Fungi, fourth ed. The American Phytopathological Society (APS) Press,
  2. St. Paul, Minnesota, USA. Burge, H.A., 2002. Fungi: toxic killers or unavoidable nuisances? Ann. Allergy Asthma Immunol. 87, 52–56.
  3. Carrer, P., Maroni, M., Alcini, D., Cavallo, D., 2001. Allergens in indoor air: environmental assessment and health effects. Sci. Total Environ. 270 (1–3), 33–42.
  4. Chen, C., Chock, D.P., Winkler, S.L., 1999. A simulation study of confounding in generalized linear models for air pollution epidemiology. Environ. Health Perspect. 107 (Number 3), 217–222.
  5. Cox, S.S., Little, J.C., Hodgson, A.T., 2002. Predicting the emission rate of volatile organic compounds from vinyl flooring. Environ. Sci. Technol. 36, 709–714.
  6. Douwes, J., Thorne, P., Pearce, N., Heederik, D., 2003. Bioaerosol health effects and exposure assessment: progress and prospects. Ann. Occup. Hyg. 47 (3), 187–200.
  7. Eisner, M.D., Balmes, J., Katz, P.P., Trupin, L., Yelin, E.H., Blanc, P.D., 2005. Lifetime environmental tobacco smoke exposure and the risk of chronic obstructive pulmonary disease. Environ. Health 4 Article number: 7. EN 13779, 2007. Ventilation for Non-residential Buildings – Performance Requirements for Ventilation and Room Conditioning Systems. The new European standard, Brussels. European Collaborative Action-IAQ (ECA), 1997. Total Volatile Organic Compounds TVOC in Indoor Air Quality Investigations [Report No. 19]. European Commission, Brussels. European Union (EU), 2008. Council directive 2008/50/EC of the European parliament and of the Council of 21 may 2008 on ambient air quality and cleaner air for Europe. Off. J. Eur. Communities-Legislation 152, 1–44 last update 18/09/2015.
  8. Godish, T., 2001. Indoor Environmental Quality. Lewis Publishers,
  9. Boca Raton. Gunchera, J., Mentese, S., Salthammer, T., Andersen, J.R., 2013. Im