Journals / PressAcademia Procedia / 2026 / Volume: 5 Issue: 1

DETERMINATION OF ENHANCEMENT EFFECTS AT THE COMPTON TO COHERENT SCATTERING INTENSITIES X-RAYS USING FE-CU AND FE-ZN BINARY COMPOUNDS WITH WDXRF

Pages
—
Publication Date
2017-06-30
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Matrix enhancement effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Matrix enhancement effects have been examined with scattered X-rays by using WDXRF system for Fe-Cu and Fe-Zn binary compounds.
📊
Key Findings & Data:Pure and binary with Fe ratio ranging from 10% to 90% samples were prepared with these elements.
💡
Conclusion & Impact:Matrix enhancement effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Analyte · enhancement · compton scattering

Abstract

Matrix enhancement effects have been examined with scattered X-rays by using WDXRF system for Fe-Cu and Fe-Zn binary compounds. Fe as analyte and elements which some of them the K absorption edge just below the characteristic K X-ray energies of the analit (Fe) as matrix have been chosen. Pure and binary with Fe ratio ranging from 10% to 90% samples were prepared with these elements. These samples have been analyzed in WDXRF system. At the end of measurement, the coherent and Compton scattering X-rays data of Rh Kα Xrays from these samples have been obtained. Matrix enhancement effects have been examined by calculating coherent / Compton scattered X-rays intensity ratio.

🔖

Cite This Article

Boydas, E., Yilmaz, D., Boydas, M. G. (2017). DETERMINATION OF ENHANCEMENT EFFECTS AT THE COMPTON TO COHERENT SCATTERING INTENSITIES X-RAYS USING FE-CU AND FE-ZN BINARY COMPOUNDS WITH WDXRF. PressAcademia Procedia, Volume: 5 Issue: 1. https://doi.org/10.17261/Pressacademia.2017.620

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Han, I., Demir, L. 2009. “Mass attenuation coefficients, effective atomic and electron numbers of Ti and Ni alloys”,Radiation. Measurement, vol.44 no. 1,pp. 289-294.
  2. Speller, R. D., Horrocks, J. A. 1991,” Photon scattering--a "new' source of information in medicine and biology?” Physics in Medicine and Biology.Vol.36, no.,pp.1.
  3. Webster, D. J., Lillicrap, S. C.1985,”Coherent-Compton scattering for the assessment of bone mineral content using heavily filtered X-ray beams”,Physics in Medicine and Biology, volume 30, no. 6, pp. 531-539.
  4. Cooper,M.J., Rollason, A.J., Tuxworth, R.W. 1982,” Gamma-ray scattering studies of composition variations in alloys” J. Phys. E: Sci. Instrum,vol.15, pp. 568-572
  5. Gigante,G.E.,. Pedraza, L.J, Sciuti, S. 1985,” Analysis of metal alloys by Rayleigh to Compton ratios and x-ray fluorescence peaks in the 50 to 122 keV energy range” Nucl. Inst. Meth, vol.12, pp. 229–234
  6. Shakeshaft,J., Morgan H.M., Lillicrap, S.C.1997, “Gamma-ray scattering for fat fraction measurement”, Physics in Medicine and Biology, vol. 42, no.7,pp. 1403-1413.
  7. Han, I., Demir, L. 2009. “Mass attenuation coefficients, effective atomic and electron numbers of Ti and Ni alloys”,Radiation. Measurement, vol.44 no. 1,pp. 289-294.
  8. Speller, R. D., Horrocks, J. A. 1991,” Photon scattering--a "new' source of information in medicine and biology?” Physics in Medicine and Biology.Vol.36, no.,pp.1.
  9. Webster, D. J., Lillicrap, S. C.1985,”Coherent-Compton scattering for the assessment of bone mineral content using heavily filtered X-ray beams”,Physics in Medicine and Biology, volume 30, no. 6, pp. 531-539.
  10. Gigante,G.E.,. Pedraza, L.J, Sciuti, S. 1985,” Analysis of metal alloys by Rayleigh to Compton ratios and x-ray fluorescence peaks in the 50 to 122 keV energy range” Nucl. Inst. Meth, vol.12, pp. 229–234