Journals / Gülhane Tıp Dergisi / 2020 / Cilt: 62 - Sayı: 3

Association Between Volume Status as Assessed by Bioelectrical Impedance Analysis and Echocardiographic Parameters in Peritoneal Dialysis Patients

Pages
179–185
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

We conclude that avoiding hypervolemia should be an important clinical goal in the follow-up of PD patients to prevent the progression of LV hypertrophy.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aims: Fluid overload is one of the major problems causing severe complications in dialysis patients and the assessment of volume status is important for these patients.
📊
Key Findings & Data:Methods: In this study, transthoracic echocardiography and BIA were performed on 35 PD patients.
💡
Conclusion & Impact:We conclude that avoiding hypervolemia should be an important clinical goal in the follow-up of PD patients to prevent the progression of LV hypertrophy.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Aims: Fluid overload is one of the major problems causing severe complications in dialysis patients and the assessment of volume status is important for these patients. The aim of the study was to evaluate the relationship of fluid overload measured by bioimpedance analysis (BIA) with different echocardiographic parameters in peritoneal dialysis (PD) patients. Methods: In this study, transthoracic echocardiography and BIA were performed on 35 PD patients. Patients were divided into two groups: overhydrated (OH) (OH ≥1.1) and non OH <1.1. This study assessed the differences in echocardiographic parameters between two groups and the association between BIA parameters and echocardiographic parameters including right heart indices. Results: A total of 35 dialysis patients (21 males) were enrolled in the study. Based on OH, 21 patients (60%) with OH ≥1.1 (lt) were considered OH and 14 patients (40%) were considered non-OH. There was no significant difference in respect to gender, age, hypertension, diabetes and dialysis vintage between two groups. Among the left heart echocardiographic parameters, left ventricular (LV) mass index (LVMI) was significantly higher in the OH group (119.0±40.3 vs. 239.4±37.4 g/m2, p=0.046). There was no significant difference with regard to other left and right ventricular echocardiographic parameters. Among various BIA parameters, we investigated OH, OH/extracellular water (ECW), ECW/total body water ratios and their correlations with echocardiographic parameters. We did not find any significant correlation between BIA parameters and echocardiographic findings. Conclusions: The present study demonstrated the association between the hydration status and LVMI. We conclude that avoiding hypervolemia should be an important clinical goal in the follow-up of PD patients to prevent the progression of LV hypertrophy.

🔖

Cite This Article

DEMİRCİ, D. E., DEMİRCİ, D., ÇOBAN, M. (2020). Association Between Volume Status as Assessed by Bioelectrical Impedance Analysis and Echocardiographic Parameters in Peritoneal Dialysis Patients. Gülhane Tıp Dergisi, Cilt: 62 - Sayı: 3, 179–185. https://ajindex.com/articles/157174

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. London GM, Marchais SJ, Metivier F, Guerin AP. Cardiovascular risk in end-stage renal disease: vascular aspects. Nephrol Dial Transplant. 2000;15:97-104.
  2. Tonelli M, Wiebe N, Culleton B, et al. Chronic kidney disease and mortality risk: a systematic review. J Am Soc Nephrol. 2006;17:2034-2047.
  3. Koc M, Toprak A, Tezcan H, Bihorac A, Akoglu E, Ozener IC. Uncontrolled hypertension due to volume overload contributes to higher left ventricular mass index in CAPD patients. Nephrol Dial Transplant. 2002;17:1661-1666.
  4. Wabel P, Chamney P, Moissl U, Jirka T. Importance of wholebody bioimpedance spectroscopy for the management of fluid balance. Blood Purif. 2009;27:75-80.
  5. Moissl UM, Wabel P, Chamney PW, et al. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas. 2006;27:921-933.
  6. Crepaldi C, Soni S, Chionh CY, Wabel P, Cruz DN, Ronco C. Application of body composition monitoring to peritoneal dialysis patients. Contrib Nephrol. 2009;163:1-6.
  7. Wizemann V, Rode C, Wabel P. Whole-body spectroscopy (BCM) in the assessment of normovolemia in hemodialysis patients. Contrib Nephrol. 2008;161:115-118.
  8. Xu Y, Chen Y, Li D, et al. Hypertension, fluid overload and micro inflammation are associated with left ventricular hypertrophy in maintenance hemodialysis patients. Ren Fail. 2013;35:1204-1209.
  9. Van Olden RW, Krediet RT, Struijk DG, Arisz L. Measurement of residual renal function in patients treated with continuous peritoneal dialysis. J Am Soc Nephrol. 1996;7:745-748. Floré KM, Delanghe JR. Analytical interferences in pointofcare testing glucometers by icodextrin and its metabolites: an overview. Perit Dial Int. 2009;29:377-383.
  10. Twardowski ZJ, Nolph KD, Prowant B, Ryan L, Moore H, Nielsen MP. Peritoneal equilibration test. Perit Dial Bull. 1987;7:138-147.
  11. Lang RM, Badano LP, Mor-Avi V, et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr. 2015;28:1-39.
  12. Rudski LG, Lai WW, Afilalo J, et al. Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography. J Am Soc Echocardiogr. 2010;23:685-713.
  13. Lang RM, Bierig M, Devereux RB, et al. Recommen