Objective & Hypothesis:The primary aim of this evaluation is to define the radiation level on performing the measurement quantitatively.
📊
Key Findings & Data:Measuring the dose rate by handheld Geiger Muller Counter provided the real radiation level during the experiment and can be used to reconfirm the safety condition of the experiment attendant.
💡
Conclusion & Impact:We also tried to build a calculation method that could be used more widely.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Geiger Muller Counter · FORTRAN · dose rate

Abstract

The primary aim of this evaluation is to define the radiation level on performing the measurement quantitatively. Three different methods were applied during this process, including simulating by FORTRAN code, measuring by Geiger Muller Counter and calculating with the activity data we had obtained. The simulation provided us an initial value range the radiation would lie in prior to our real operation. It acted as a guide. Measuring the dose rate by handheld Geiger Muller Counter provided the real radiation level during the experiment and can be used to reconfirm the safety condition of the experiment attendant. However, due to the fact that only copper sample from 9 MeV was detected by the Geiger Muller Counter, situation for other energy levels would be predicted by the calculation attempt. We also tried to build a calculation method that could be used more widely.

🔖

Cite This Article

Qadr, H. M., Mamand, D. (2022). Monte Carlo calculation of absorbed dose under MeV proton irradiation. Journal of Physical Chemistry and Functional Materials, Volume: 5 Issue: 2. https://doi.org/10.54565/jphcfum.1143673

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. Hiwa M Q, The use of the MCNP Code for Radiation Damage Calculations, Mathematical Physics and Computer Modeling, 24(1) (2021)
  2. Muroga T, Gasparotto M, Zinkle S J, Overview of materials research for fusion reactors, Fusion engineering and design, 61(2002): 13-25
  3. Qadr H M, Radiation damage and dpa in iron using mcnp5, European Journal of Materials Science and Engineering, 5(3) (2020): 109-114
  4. Park S H, Kang J O, Basics of particle therapy I: physics, Radiation oncology journal, 29(3) (2011): 135.