Possible effects of 3200 MHz radio-frequency field on cardiac blood parameters in rats

Nurhan Özdemir(ANKARA MEDİPOL UNIVERSITY)0000-0001-6414-7587
Enis Taha Özkan(GAZİ ÜNİVERSİTESİ, TIP FAKÜLTESİ)0000-0001-6248-4061
Burak Kayabaşı(GAZİ ÜNİVERSİTESİ, TIP FAKÜLTESİ)0000-0003-4252-3873
Sevilay Günay(GAZI UNIVERSITY, SCHOOL OF MEDICINE)0000-0002-0130-5629
Gül Bayramiye Özmen(GAZİ ÜNİVERSİTESİ, REKTÖRLÜK)0000-0002-5649-9950
Sinem Oruç Eraslan(FIRAT UNIVERSITY, SCHOOL OF MEDICINE)0000-0001-9124-1245
Kayhan Ateş(AKDENİZ ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ)0000-0002-6016-6577
Bahriye Sirav(GAZI UNIVERSITY, SCHOOL OF MEDICINE)0000-0001-6003-6556
Sibel Dinçer(GAZI UNIVERSITY, SCHOOL OF MEDICINE)0000-0002-0946-2899
Pages
—
Publication Date
2026-05-19
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Exposure to a 3200 MHz RF field at SAR levels of 0.3-0.36 W/kg did not significantly alter cardiac biomarkers, including troponin I and BNP, under the experimental conditions of this study.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aims: Radiofrequency (RF) technologies are widely used in modern communication systems, particularly with the introduction of fifth-generation (5G) networks.
📊
Key Findings & Data:This study aimed to evaluate the effects of repeated exposure to a 3200 MHz RF field on cardiac injury biomarkers in a rat model.
💡
Conclusion & Impact:Conclusion: Exposure to a 3200 MHz RF field at SAR levels of 0.3-0.36 W/kg did not significantly alter cardiac biomarkers, including troponin I and BNP, under the experimental conditions of this study.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Radio-frequency radiation · troponin i · creatine kinase natriuretic peptide

Abstract

Aims: Radiofrequency (RF) technologies are widely used in modern communication systems, particularly with the introduction of fifth-generation (5G) networks. Despite increasing exposure to RF fields, their potential biological effects remain controversial. This study aimed to evaluate the effects of repeated exposure to a 3200 MHz RF field on cardiac injury biomarkers in a rat model. We hypothesized that repeated RF exposure would induce measurable alterations in cardiac biomarkers. Methods: Thirty-four male Wistar albino rats (220-280 g) were randomly assigned to five groups: control, sham-15 min, sham-1 h, RF exposure-15 min, and RF exposure-1 h. Animals in exposure groups were subjected to a 3200 MHz RF field for 15 minutes or 1 hour daily for 15 consecutive days. Serum troponin I, creatine kinase (CK), and plasma brain natriuretic peptide (BNP) levels were measured using the Abbott Alinity I immunoassay autoanalyzer (Abbott Laboratories, Abbott Park, IL, USA). Statistical analyses were performed using GraphPad software. Results: No statistically significant differences were observed in troponin I or BNP levels among the groups (p<0.05). A statistically significant increase in CK levels was detected only between the sham-15 min and RF exposure-15 min groups (p<0.05), as well as between the control and sham-15 min groups. No consistent biomarker elevation associated with RF exposure duration was identified. Conclusion: Exposure to a 3200 MHz RF field at SAR levels of 0.3-0.36 W/kg did not significantly alter cardiac biomarkers, including troponin I and BNP, under the experimental conditions of this study.

🔖

Cite This Article

Özdemir, N., Özkan, E. T., Kayabaşı, B., Günay, S., Özmen, G. B., Eraslan, S. O., Ateş, K., Sirav, B., Dinçer, S. (2026). Possible effects of 3200 MHz radio-frequency field on cardiac blood parameters in rats. Journal of Health Sciences and Medicine, Volume: 9 Issue: 3. https://doi.org/10.32322/jhsm.1872707

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (35)

  1. Delen K, Sırav B, Oruç S, et al. Effects of 2600 MHz radiofrequency radiation in brain tissue of male Wistar rats and neuroprotective effects of melatonin. Bioelectromagnetics. 2021;42(2):159-172. doi:10.1002/bem.22318
  2. Gökoğlan E, Ekinci M, Özgenç E, İlem-Özdemir D, Aşıkoğlu M. Radyasyon ve insan sağlığı üzerindeki etkileri. Anat Clin J Med Sci. 2020;25(3):289-294. doi:10.21673/anadoluklin.709434
  3. Akkurt R. Geçmişten günümüze kablosuz mobil iletişim teknolojileri. Avr Bil Teknol Derg. 2021;(28):115-119. doi:10.31590/ejosat.991625
  4. Rahman MM, Khatun F, Sami SI, Uzzaman A. The evolving roles and impacts of 5G enabled technologies in healthcare: the world epidemic COVID-19 issues. Array. 2022;14:100178. doi:10.1016/j.array.2022.100178
  5. International Commission on Non-Ionizing Radiation Protection. Guidelines for limiting exposure to electromagnetic fields (100 kHz to 300 GHz). Health Phys. 2020;118(5):483-524. doi:10.1097/HP.00000000 00001210
  6. Dasdag S, Akdag MZ. The link between radiofrequencies emitted from wireless technologies and oxidative stress. J Chem Neuroanat. 2016;75: 85-93. doi:10.1016/j.jchemneu.2015.09.001
  7. Yakymenko I, Tsybulin O, Sidorik E, Henshel D, Kyrylenko O, Kyrylenko S. Oxidative mechanisms of biological activity of low-intensity radiofrequency radiation. Electromagn Biol Med. 2016;35(2):186-202. doi: 10.3109/15368378.2015.1043557
  8. Megha K, Deshmukh PS, Banerjee BD, Tripathi AK, Ahmed R, Abegaonkar MP. Low intensity microwave radiation induced oxidative stress, inflammatory response and DNA damage in rat brain. Neurotoxicology. 2015;51:158-165. doi:10.1016/j.neuro.2015.10.009
  9. IARC Working Group on the Evaluation of Carcinogenic Risks to Humans. Non-Ionizing Radiation, Part 2: Radiofrequency Electromagnetic Fields. International Agency for Research on Cancer; 2013. IARC Monographs on the Evaluation of Carcinogenic Risks to Humans, No. 102.
  10. Marino C, Croft R, Hirata A, et al. Gaps in knowledge relevant to the “ICNIRP Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic and Electromagnetic Fields (100 kHz to 300 GHz).” Health Phys. 2025;128(2):190-202. doi:10.1097/HP.0000000000001944
  11. World Health Organization. Electromagnetic fields and public health: mobile phones. Fact Sheet. 2014:193.
  12. Singh N, Rathore V, Mahat RK, Rastogi P. Glycogen phosphorylase BB: a more sensitive and specific marker than other cardiac markers for early diagnosis of acute myocardial infarction. Indian J Clin Biochem. 2018; 33(3):356-360. doi:10.1007/s12291-017-0685-y
  13. Rathish R, Gunalan G, Sumathi P. Current biomarkers for myocardial infarction. Int J Pharm Biol Sci. 2013;4(1):434-442.
  14. Miyahara Y, Nagaya N, Kataoka M, et al. Monolayered mesenchymal stem cells repair scarred myocardium after myocardial infarction. Nat Med. 2006;12(4):459-465. doi:10.1038/nm1391
  15. Alpert JS, Thygesen K, Antman E, Bassand JP. Myocardial infarction redefined-a consensus document of the Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. J Am Coll Cardiol. 2000;36(3):959-969. doi:10.1016/S0735-1097(00)00804-4
  16. Stein BC, Levin RI. Natriuretic peptides: physiology, therapeutic potential, and risk stratification in ischemic heart disease. Am Heart J. 1998;135(5):914-923. doi:10.1016/S0002-8703(98)70054-7
  17. Atlasz T, Kellényi L, Kovács P, et al. The application of surface plethysmography for heart rate variability analysis after GSM radiofrequency exposure. J Biochem Biophys Methods. 2006;69(1-2):233-236. doi:10.1016/j.jbbm.2006.03.017
  18. Wilén J, Johansson A, Kalezic N, Lyskov E, Sandström M. Psychophysiological tests and provocation of subjects with mobile phone related symptoms. Bioelectromagnetics. 2006;27(3):204-214. doi: 10.1002/bem.20195
  19. Montzeri A, Pooladi M, Odoumizadeh M, Nazarian N, Karani S. The effects of WiFi network (2.45 GHz) in rats with induced stroke associated with an increased risk of heart attack. J Paramed Sci. 2019; 10:2. doi:10.22037/jps.v9i2.24145
  20. International Commission on Non-Ionizing Radiation Protection. Gaps in knowledge relevant to the “ICNIRP Guidelines for Limiting Exposure to Time-Varying Electric, Magnetic and Electromagnetic Fields (100 kHz to 300 GHz).” Health Phys. 2025;128(2):190-202. doi:10.1097/HP. 0000000000001944
  21. Yavaş MC, Yegin K, Oruç S, Delen K, Sırav B. Analysis of thiol/disulphide homeostasis and oxidant-antioxidant status as a result of exposure to radio-frequency electromagnetic fields. Electromagn Biol Med. 2021;40(1):84-91. doi:10.1080/15368378.2021.1874970
  22. Özen Ş, Helhel S, Çerezci O. Heat analysis of biological tissue exposed to microwave by using thermal wave model of bio-heat transfer (TWMBT). Burns. 2008;34(1):45-49. doi:10.1016/j.burns.2007.01.009
  23. Gökçek-Saraç Ç, Akçay G, Karakurt S, Ateş K, Özen Ş, Derin N. Possible effects of different doses of 2.1 GHz electromagnetic radiation on learning, and hippocampal levels of cholinergic biomarkers in Wistar rats. Electromagn Biol Med. 2021;40(1):179-190. doi:10.1080/15368378.2020.1851251
  24. Özevci G, Ceyhan B, Atakır K. Artan cep telefonu kullanımının insan sağlığı üzerine etkileri. Dünya Sağlık Tabiat Bil Derg. 2021;4(2):80-93.
  25. Çakır FS, Aytekin A, Tüminçin F. Nesnelerin interneti ve giyilebilir teknolojiler. Sosyal Araşt Davranış Bil Derg. 2018;4(5):84-95.
  26. Andrzejak R, Poreba R, Poreba M, et al. The influence of the call with a mobile phone on heart rate variability parameters in healthy volunteers. Ind Health. 2008;46(4):409-417. doi:10.2486/indhealth.46.409
  27. Ekici B, Tanındı A, Ekici G, Diker E. The effects of the duration of mobile phone use on heart rate variability parameters in healthy subjects. Anatol J Cardiol. 2016;16(11):833-838. doi:10.14744/AnatolJCardiol.2016.6717
  28. Ahlbom A, Green A, Kheifets L, Savitz D, Swerdlow A. Epidemiology of health effects of radiofrequency exposure. Environ Health Perspect. 2004;112(17):1741-1754. doi:10.1289/ehp.7306
  29. Johansen C. Electromagnetic fields and health effects-epidemiologic studies of cancer, diseases of the central nervous system and arrhythmia-related heart disease. Scand J Work Environ Health. 2004;30(suppl 1):1-80.
  30. Zosangzuali M, Lalremruati M, Lalmuansangi C, et al. Effects of radiofrequency electromagnetic radiation emitted from a mobile phone base station on the redox homeostasis in different organs of Swiss albino mice. Electromagn Biol Med. 2021;40(3):393-407. doi:10.1080/15368378. 2021.1895207
  31. Karamazı Y, Emre M, Çetiner S, et al. 5G (6 GHz) radyofrekans elektromanyetik alanın sıçan kan hücrelerinde canlılık, apopitotik ve nekrotik hücre oranına etkisinin araştırılması. Arş Kaynak Tarama Derg. 2023;32(1):16-25. doi:10.17827/aktd.1221723
  32. Irnich W, Batz L, Müller R, Tobisch R. Electromagnetic interference of pacemakers by mobile phones. Pacing Clin Electrophysiol. 1996;19(10): 1431-1446. doi:10.1111/j.1540-8159.1996.tb03155.x
  33. Naegeli B, Osswald S, Deola M, Burkart F. Intermittent pacemaker dysfunction caused by digital mobile telephones. J Am Coll Cardiol. 1996;27(6):1471-1477. doi:10.1016/0735-1097(96)00031-9
  34. Colak C, Parlakpinar H, Ermis N, et al. Effects of electromagnetic radiation from 3G mobile phone on heart rate, blood pressure and ECG parameters in rats. Toxicol Ind Health. 2012;28(7):629-634. doi:10.1177/0748233711420468
  35. Moussa S. Oxidative stress in rats exposed to microwave radiation. Rom J Biophys. 2009;19(2):149-158.