Journals / ENT Updates / 2020 / Cilt: 10 - Sayı: 2

Reconstruction of orbital floor fractures using a porous polyethylene implant: Outcomes in the early, intermediate and late postoperative periods

Pages
321–325
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

To prevent or minimize postoperative complications, the orbital septum must be repaired meticulously.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The porous polyethylene implant (PPEI) is one of the most commonly used alloplastic materials in cranio-maxillofacial surgery.
📊
Key Findings & Data:It is widely preferred because of its biocompatible, durable, flexible and thin nature as well as for its low complication rates.
💡
Conclusion & Impact:To prevent or minimize postoperative complications, the orbital septum must be repaired meticulously.
🔬Design:Review & Systematic Survey
📍Scope:2000 Verileri
⚙️Variables:Domain Parameters

Özet

Objective: The porous polyethylene implant (PPEI) is one of the most commonly used alloplastic materials in cranio-maxillofacial surgery. It is widely preferred because of its biocompatible, durable, flexible and thin nature as well as for its low complication rates. The purpose of the present study was to review the clinical and surgical outcomes of PPEI usage for orbital floor fractures. Methods: The present study included 76 patients who underwent orbital floor fracture reconstruction using PPEI between July 2000 and July 2018. All demographic characteristics of the patients were recorded and the patients were questioned and/or examined whether there was any complaint or complication secondary to the surgery. Results: The mean age of the patients was 35.2 years with a male predominance. The most common causes of injury were in-vehicle traffic accidents, falls, physical assaults and pedestrian accidents, respectively. 73 patients had other concomitant fractures of the facial bones along with the orbital floor fracture. The mean time between the injury and the surgical repair was eight days. Scleral show was observed in two patients (2.6%) due to scar contracture of the subciliary incision whereas one patient had surgical removal of the PPEI. Conclusion: The present study revealed that PPEI is a reliable and flexible material for the reconstruction of orbital floor fractures with a low risk of complications. To prevent or minimize postoperative complications, the orbital septum must be repaired meticulously.

🔖

Cite This Article

ÖZKAYA, N. K., ERCÖCEN, A. R. (2020). Reconstruction of orbital floor fractures using a porous polyethylene implant: Outcomes in the early, intermediate and late postoperative periods. ENT Updates, Cilt: 10 - Sayı: 2, 321–325. https://ajindex.com/articles/149960

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Ellis E 3rd, el-Attar A, Moos KF. An analysis of 2,067 cases of zygomatico-orbital fracture. J Oral Maxillofac Surg 1985;43:417-28
  2. Burnstine MA. Clinical recommendations for repair of isolated orbital floor fractures: an evidence-based analysis. Ophthalmology 2002;109:1207-10
  3. Hsu CK, Hsieh MW, Chang HC, Tai MC, Chien KH. Anatomic Factors Predicting Postoperative Strabismus in Orbital Wall Fracture Repair. Sci Rep 2019;9:14785
  4. Al-Moraissi EA, Thaller SR, Ellis E. Subciliary vs. transconjunctival approach for the management of orbital floor and periorbital fractures: a systematic review and meta-analysis.J Craniomaxillofac Surg 2017;45:1647-54
  5. Pedemonte C, Muñoz T, Valenzuela K, Díaz M, González LE, Vargas I. Reconstruction of medial orbital wall using a retrocaruncular approach. J Craniomaxillofac Surg 2018;46:1726-30
  6. Pagnoni M, Giovannetti F, Amodeo G, Priore P, Iannetti G. Endoscopic endonasal versus transfacial approach for blowout fractures of the medial orbital wall. J Craniofac Surg 2015;26:247-9
  7. Soejima K, Shimoda K, Kashimura T, et al. Endoscopic transmaxillary repair of orbital floor fractures: a minimally invasive treatment. J Plast Surg Hand Surg 2013;47:368-73
  8. Wu PS, Matoo R, Sun H, Song LY, Kikkawa DO, Lu W. Single-stage soft tissue reconstruction and orbital fracture repair for complex facial injuries. J Plast Reconstr Aesthet Surg 2017;70:1-6
  9. Al-Moraissi E, Elsharkawy A, Al-Tairi N, et al. What surgical approach has the lowest risk of the lower lid complications in the treatment of orbital floor and periorbital fractures? A frequentist network meta-analysis. J Craniomaxillofac Surg 2018;46:2164-75
  10. Jazayeri HE, Khavanin N, Yu JW, et al. Does Early Repair of Orbital Fractures Result in Superior Patient Outcomes? A Systematic Review and Meta-Analysis. J Oral Maxillofac Surg 2020;78:568-77
  11. Neovius E, Clarliden S, Farnebo F, Lundgren TK. Lower Eyelid Complications in Facial Fracture Surgery. J Craniofac Surg 2017;28:391-3
  12. Kronig SA, van der Mooren RJ, Strabbing EM, et al. Pure orbital blowout fractures reconstructed with autogenous bone grafts: functional and aesthetic outcomes. Int J Oral Maxillofac Surg 2016;45:507-12
  13. Sakakibara S, Hashikawa K, Terashi H, Tahara S. Reconstruction of the orbital floor with sheets of autogenous iliac cancellous bone. J Oral Maxillofac Surg 2009;67:957-61
  14. Polacco MA, Kahng PW, Sudoko CK, Gosselin BJ. Orbital Floor Reconstruction: a Comparison of Outcomes b