Journals / ENT Updates / 2020 / Cilt: 10 - Sayı: 1

Closed reduction of zygomatic arch fractures using a Tubbs-Logan mitral valve dilator

Pages
278–283
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

We think that further ergonomic modifications would be beneficial to improve the positioning of the instrument in restricted areas observed due to severe depression of the zygomatic arch.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To present technical details and experiences regarding the use of a Tubbs-Logan mitral valve dilator for the closed reduction of zygomatic arch fractures.
📊
Key Findings & Data:Method: Over a period of about three years, closed reduction was indicated and performed in 22 patients with a zygomatic arch fracture.
💡
Conclusion & Impact:We think that further ergonomic modifications would be beneficial to improve the positioning of the instrument in restricted areas observed due to severe depression of the zygomatic arch.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

Objective: To present technical details and experiences regarding the use of a Tubbs-Logan mitral valve dilator for the closed reduction of zygomatic arch fractures. Method: Over a period of about three years, closed reduction was indicated and performed in 22 patients with a zygomatic arch fracture. In all patients, depressed fracture segments were reduced using a Tubbs-Logan mitral valve dilator via the Gillies’ temporal approach. Results: The majority of the injuries were due to motor vehicle collisions (n=8, 36.4%). The zygomatic arch fracture was isolated in 12 patients (54.5%). However, it was a component of a zygomatic complex fracture in 10 patients (45.5%). Of those, rigid internal fixation of the zygomatic body was performed in 8 and the zygomatic body was only closely reduced by a bone hook in 2 patients. Repair of a concomitant orbital floor fracture was performed in 2, a mandibular angle fracture in 1 and a frontal sinus fracture in 1 patient. The reduction status of the zygomatic arch was excellent in 12 (54.5%), good in 8 (36.4%) and fair in 2 patients (9.1%). During the follow-ups, no functional or cosmetic sequelae regarding repaired fractures of the zygomatic arch, zygomatic body or other facial bones were recorded. Conclusion: We suggest that the Tubbs-Logan mitral valve dilator is a safe and effective alternative in terms of closed reduction of zygomatic arch fractures, whether they are isolated or not. We think that further ergonomic modifications would be beneficial to improve the positioning of the instrument in restricted areas observed due to severe depression of the zygomatic arch.

🔖

Cite This Article

YONTAR, Y., TATAR, S., BAYKAN, H. (2020). Closed reduction of zygomatic arch fractures using a Tubbs-Logan mitral valve dilator. ENT Updates, Cilt: 10 - Sayı: 1, 278–283. https://ajindex.com/articles/149253

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (17)

  1. Mundinger GS, Dorafshar AH, Gilson MM, et al. Analysis of radiographically confirmed blunt-mechanism facial fractures. J Craniofac Surg 2014;25:321-7
  2. Gomes PP, Passeri LA, Barbosa JR. A 5-year retrospective study of zygomatico-orbital complex and zygomatic arch fractures in Sao Paulo State, Brazil. J Oral Maxillofac Surg 2006;64:63-7
  3. Kiwanuka E, Smith SE, Frates MC, Caterson EJ. Use of high-frequency ultrasound guidance for intraoperative zygomatic arch fracture reduction. J Craniofac Surg 2013;24:2036-8
  4. Yamamoto K, Murakami K, Sugiura T, et al. Clinical analysis of isolated zygomatic arch fractures. J Oral Maxillofac Surg 2007;65:457-61
  5. Hindin DI, Muetterties CE, Mehta C, Boukovalas S, Lee JC, Bradley JP. Treatment of Isolated Zygomatic Arch Fracture: improved Outcomes with External Splinting. Plast Reconstr Surg 2017;139:1162-71
  6. Ozyazgan I, Günay GK, Eskitaşçioglu T, Ozköse M, Coruh A. A new proposal of classification of zygomatic arch fractures. J Oral Maxillofac Surg 2007;65:462-9
  7. Gündeşlioğlu ÖA, Özen C, Inan I, et al. Closed reduction of zygoma tripod and isolated arch fractures with Volkmann bone hook. Kulak Burun Bogaz Ihtis Derg 2013;23:211-6
  8. Zingg M, Laedrach K, Chen J, et al. Classification and treatment of zygomatic fractures: a review of 1,025 cases. J Oral Maxillofac Surg 1992;50:778-90
  9. Podoshin L, Fradis M. The use of the foley balloon catheter in zygomatic-arch fractures. Br J Oral Surg 1974;12:246-8
  10. El-Hadidy AM. The use of a Foley catheter in isolated zygomatic arch fractures. Plast Reconstr Surg 2005;116:853-6
  11. Randall DA, Bernstein PE. Epistaxis balloon catheter stabilization of zygomatic arch fractures. Ann Otol Rhinol Laryngol 1996;105:68-9
  12. Mezitis M, Stathopoulos P, Rallis G. Use of a curved mosquito for reducing isolated zygomatic arch fractures. J Craniofac Surg 2010;21:1281-3
  13. Hwang K, Lee SI. Reduction of zygomatic arch fracture using a towel clip. J Craniofac Surg 1999;10:439-41
  14. Baek JE, Chung CM, Hong IP. Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw. Arch Plast Surg 2012;39:556-60
  15. Giudice A, Colangeli W, Cristofaro MG. Percutaneous reduction of an isolated zygomatic fracture using a wire suture. Br J Oral Maxillofac Surg 2013;51:201-2
  16. Buhr J, Hürtgen M, Kelm C, Schwemmle K. Tumor dissemination after thoracoscopic resection for lung cancer. J Thorac Cardiovasc Surg 1955;110:855-6
  17. Rainer WG. Cardiac surgery before cardiopulmonary byp