Journals / Electrica / 2019 / Cilt: 19 - Sayı: 2

An Effective Method for Islanding Detection Based on Variational Mode Decomposition

Journal
Electrica
Pages
135–145
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results demonstrate the desired performance of the method with respect to both speed and accuracy.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The present study presents a new islanding detection method based on variational mode decomposition (VMD).
📊
Key Findings & Data:The results illustrate desired performance of the proposed algorithm for conditions such as motor, nonlinear, and large load switching; as normal condition; and islanding condition with a variety of power mismatches between local load and distributed generation.
💡
Conclusion & Impact:The results demonstrate the desired performance of the method with respect to both speed and accuracy.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

The present study presents a new islanding detection method based on variational mode decomposition (VMD). In the method, the VMD transform of the voltage at point of common coupling is calculated, and then based on the decomposed modes, an islanding detection index for distinguishing between islanding and normal conditions will be derived. Pursuing this objective, the measured voltage is decomposed into four modes, and a new islanding detection index will be derived from their energy and their variations. Then, thresholds will be adjusted based on values of proposed index in various conditions on normal and islanding operations. The proposed algorithm decomposes the measured signal into a predetermined number of intrinsic modes around central frequencies; the method is insensitive to the noise and sampling frequency. To validate the method, a distribution network has been simulated in PSCAD/EMTDC, and the algorithm is tested on a variety of islanding and normal circumstances. The results illustrate desired performance of the proposed algorithm for conditions such as motor, nonlinear, and large load switching; as normal condition; and islanding condition with a variety of power mismatches between local load and distributed generation. The results demonstrate the desired performance of the method with respect to both speed and accuracy.

🔖

Cite This Article

SALİMİ, S., KOOCHAKİ, A. (2019). An Effective Method for Islanding Detection Based on Variational Mode Decomposition. Electrica, Cilt: 19 - Sayı: 2, 135–145. https://ajindex.com/articles/149224

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. H. Vahedi, G. B. Gharehpetian, M. Karrari, “Application of duffing oscillators for passive islanding detection of inverter-based distributed generation units”, IEEE Trans. on Power Delivery, vol. 27, no. 4, pp. 1973-1983, Oct. 2012.
  2. D. Velasco, C.L. Trujillo, G. Garcerá, E. Figueres, “Review of anti-islanding techniques in distributed generators”, Renewable and Sustainable Energy Reviews, vol. 14, no. 6, pp. 1608-1614, 2010. V. Task, “Evaluation of islanding detection methods for photovoltaic utility interactive power systems”, in International energy agency implementing agreement on photovoltaic power systems, Tech. Rep.IEA-PVPS T5-09, March 2002.
  3. F. De Mango, M. Liserre, A. Dell’Aquila, A. Pigazo, “Overview of anti-islanding algorithms for PV systems. Part I: passive methods”, 12th International Power Electronics and Motion Control Conf., Portoroz, 2006, pp. 1878-1883.
  4. N. Liu, C. P. Diduch, L. Chang, J. Su, “A reference impedance-based passive islanding detection method for inverter-based distributed generation system”, IEEE Journal of Emerging and Selected Topics in Power Electronics, vol.3, no.4, pp. 1205-1217, 2015.
  5. N. Liu, A. Aljankawey, C. Diduch, L. Chang, J. Su, “Passive islanding detection approach based on tracking the frequency-dependent impedance change”, IEEE Trans. on Power Delivery, vol. 30, no. 6, pp. 2570-2580, Dec. 2015. [CrossRef] 7. J. Yin, C. P. Diduch, L. Chang, “Islanding detection using proportional power spectral density”, IEEE Trans. on Power Delivery, vol. 23, no. 2, pp. 776-784, April 2008.
  6. A. Yafaoui, B. Wu, S. Kouro, “Improved active frequency drift anti-islanding detection method for grid connected photovoltaic systems”, IEEE Trans. on Power Electronics, vol. 27, no. 5, pp. 23672375, May 2012.
  7. A. Ghaderi, M. Kalantar, A. Esmaeilian, “A novel islanding detection method for constant current inverter based distributed generations”, 2011 10th International Conference on Environment and Electrical Engineering, Rome, 2011, pp. 1-4.
  8. H. H. Zeineldin, J. L. Kirtley, “Performance of the OVP/UVP and OFP/UFP method with voltage and frequency dependent loads”, IEEE Trans. on Power Delivery, vol. 24, no. 2, pp. 772-778, April 2009.
  9. Z. Ye, A. Kolwalkar, Y. Zhang, P. Du, R. Walling, “Evaluation of anti-islanding schemes based on nondetection zone concept”, IEEE Trans. on Power Electronics, vol. 19, no. 5, pp. 1171-1176, Sept. 2004.
  10. B. Singam, L. Y. Hui, “Assessing SMS and PJD schemes of anti-islanding with varying quality factor”, IEEE Inte