Journals / Environmental Research and Technology / 2026 / Volume: 3 Issue: 1

Assessment of physicochemical characteristics of groundwater collected from different taluks, Dindigul district, Tamilnadu, India

Chellaiah Edward Raja(Department of Molecular Biology, Madurai Kamaraj University)0000-0002-5559-7946
Pages
—
Publication Date
2020-03-31
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

According to BIS and WHO standard, low concentration of F - below 0.5 ppm may increase the risk of tooth decay.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:To evaluate the physicochemical characteristics, water samples were collected from thirty-three villages at Dindigul district.
📊
Key Findings & Data:From the analysis, pH of the all samples were varying from 6.64 to 8.17.
💡
Conclusion & Impact:According to BIS and WHO standard, low concentration of F - below 0.5 ppm may increase the risk of tooth decay.
🔬Design:Research Article
📍Scope:2000 Verileri
⚙️Variables:Groundwater · fluoride · physiochemical parameters

Abstract

To evaluate the physicochemical characteristics, water samples were collected from thirty-three villages at Dindigul district. From the analysis, pH of the all samples were varying from 6.64 to 8.17. The pH values are within the permissible limit. In Natham taluk, bore wells samples showed extreme (991, 963 and 951 mg L -1 ) total dissolved solids (TDS) values when compared to maximum permissible TDS is 600 mg L -1 . The taste of water comes under poor TDS rating. The highest total hardness (TH) 725 mg L -1 was tested at Silukuvarpatti bore well in Nilakottai taluk. Residual free Chlorine and Iron were not detected in any of the samples. All samples showed Nitrate (NO 3 - ) concentrations were ranged from 0 to 25 mg L -1 . The values are less than NO 3 - desirable limit, that is 45 mg L -1 respectively. Maximum number of samples showed chloride (Cl - ) values were higher than Cl- permissible limit (1000 mg L -1 ) as referenced by BIS. The highest Cl - values were obtained at 2950 and 2000 mg L -1 in Pudukkottai well and Sengulam bore well taken from Reddiyarchatiram and Natham taluks. In regards to fluoride (F - ) contamination, thirty-four samples showed < 0.5 ppm F - and rest of fourteen samples viewed <1ppm F - . According to BIS and WHO standard, low concentration of F - below 0.5 ppm may increase the risk of tooth decay.

🔖

Cite This Article

Raja, C. E. (2020). Assessment of physicochemical characteristics of groundwater collected from different taluks, Dindigul district, Tamilnadu, India. Environmental Research and Technology, Volume: 3 Issue: 1. https://doi.org/10.35208/ert.658910

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Kiyoshi OMINE (Dr. Eng, Professor) Department of Civil Engineering Nagasaki University 1-14
  2. Bunkyo-machi, Nagasaki 852-8521, JAPAN E-mail: [email protected] TEL +81-995-819-2621 FAX +81-95-819-2627 Dr. G. MARIMUTHU INSA Senior Scientist Department of Animal Behavior & Physiology School of Biological Sciences Madurai Kamaraj University Madurai 625 021, India. Ph: +91-452-2459116 E-mail:[email protected]