Journals / Türk Pediatri Arşivi / 2026 / Cilt: 38 Sayı: 1

Zinc and copper levels in cord blood and mother’s serum Original Article

Anne ve kord serumunda çinko ve bakır düzeyleri Orijinal Araştırma

Pages
—
Publication Date
2003-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Zinc and copper are trace elements involved in many metabolic processes and enzyme systems The aim of this study was to determine plasma zinc and copper concentrations in paired samples of maternal and umbilical cord blood from 45 mothers at delivery looking for an association between trace element levels and mother’s age and birth weight Zinc and copper concentrations were determined by atomic absorption spectroscopy Mean zinc concentrations in newborns were statistically higher than those in mothers p=0 001 In contrast; mean copper concentration in newborns were statistically lower than those in mothers p lt;0 001 There were no correlations between maternal age and plasma zinc and copper concentrations of neonates r=0 149 r=0 175 respectively No correlations were found between maternal plasma zinc and copper concentration and birth weight of neonates r=0 2 r= 0 175 respectively Key words: zinc copper newborn

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Zinc and copper are trace elements involved in many metabolic processes and enzyme systems The aim of this study was to determine plasma zinc and copper concentrations in paired samples of maternal and umbilical cord blood from 45 mothers at delivery looking for an association between trace element levels and mother’s age and birth weight Zinc and copper concentrations were determined by atomic absorption spectroscopy Mean zinc concentrations in newborns were statistically higher than those in mothers p=0 001 In contrast; mean copper concentration in newborns were statistically lower than those in mothers p lt;0 001 There were no correlations between maternal age and plasma zinc and copper concentrations of neonates r=0 149 r=0 175 respectively No correlations were found between maternal plasma zinc and copper concentration and birth weight of neonates r=0 2 r= 0 175 respectively Key words: zinc copper newborn
📊
Key Findings & Data:Zinc and copper are trace elements involved in many metabolic processes and enzyme systems The aim of this study was to determine plasma zinc and copper concentrations in paired samples of maternal and umbilical cord blood from 45 mothers at delivery looking for an association between trace element levels and mother’s age and birth weight Zinc and copper concentrations were determined by atomic absorption spectroscopy Mean zinc concentrations in newborns were statistically higher than those in mothers p=0 001 In contrast; mean copper concentration in newborns were statistically lower than those in mothers p lt;0 001 There were no correlations between maternal age and plasma zinc and copper concentrations of neonates r=0 149 r=0 175 respectively No correlations were found between maternal plasma zinc and copper concentration and birth weight of neonates r=0 2 r= 0 175 respectively Key words: zinc copper newborn
💡
Conclusion & Impact:Zinc and copper are trace elements involved in many metabolic processes and enzyme systems The aim of this study was to determine plasma zinc and copper concentrations in paired samples of maternal and umbilical cord blood from 45 mothers at delivery looking for an association between trace element levels and mother’s age and birth weight Zinc and copper concentrations were determined by atomic absorption spectroscopy Mean zinc concentrations in newborns were statistically higher than those in mothers p=0 001 In contrast; mean copper concentration in newborns were statistically lower than those in mothers p lt;0 001 There were no correlations between maternal age and plasma zinc and copper concentrations of neonates r=0 149 r=0 175 respectively No correlations were found between maternal plasma zinc and copper concentration and birth weight of neonates r=0 2 r= 0 175 respectively Key words: zinc copper newborn
🔬Design:Makale
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Zinc and copper are trace elements involved in many metabolic processes and enzyme systems The aim of this study was to determine plasma zinc and copper concentrations in paired samples of maternal and umbilical cord blood from 45 mothers at delivery looking for an association between trace element levels and mother’s age and birth weight Zinc and copper concentrations were determined by atomic absorption spectroscopy Mean zinc concentrations in newborns were statistically higher than those in mothers p=0 001 In contrast; mean copper concentration in newborns were statistically lower than those in mothers p lt;0 001 There were no correlations between maternal age and plasma zinc and copper concentrations of neonates r=0 149 r=0 175 respectively No correlations were found between maternal plasma zinc and copper concentration and birth weight of neonates r=0 2 r= 0 175 respectively Key words: zinc copper newborn

Özet

Çalışmada anne ve bebek kanında çinko ve bakır düzeylerinin saptanması annelerin serum çinko ve bakır düzeyleri ve anne yaşı ile bebeklerin doğum ağırlıkları serum çinko ve bakır düzeyleri arasında olası bir korelasyonun belirlenmesi amaçlanmıştır Aydın Doğumevi ile Adnan Menderes Üniversitesi Tıp Fakültesi Kadın Hastalıkları ve Doğum Kliniği’nde 1 Eylül 1999 1 Aralık 1999 tarihleri arasında doğum yapan 45 anne ve bebeği çalışma grubunu oluşturmuştur Çinko ve bakır düzeylerinin tayini atomik absorbsiyon spektrofotometri tekniği ile yapılmıştır Bebeklerin ortalama serum çinko düzeyleri 79 5±18 3 48 122 ìg dl annelerin ortalama serum çinko düzeylerinden 64 3±13 5 32 94 61549;g dl anlamlı olarak yüksek bulundu p=0 001 Bebeklerin ortalama serum bakır düzeyi 130 6±69 9 61549;g dl annelerin ortalama serum bakır düzeylerinden 245 3±83 2mg dl anlamlı olarak düşük bulundu p lt;0 001 Anne yaşı ile bebeklerin çinko ve bakır düzeyleri arasında korelasyon saptanmadı r=0 149 r=0 175 Annelerin serum çinko ve bakır değerleri ile bebeklerin doğum kiloları arasında korelasyon tespit edilmedi r=0 2 r= 0 175 Sonuçlarımız literatüre uygun şekilde; anne çinko düzeylerinin bebek düzeylerinden düşük anne bakır düzeylerinin ise bebek düzeylerinden yüksek olduğunu göstermektedir Anahtar Kelimeler: çinko bakır kord serumu

🔖

Cite This Article

Türkmen, M., Karul, A. B., İnan, G., Yensel, N., Sönmez, F., Akçanal, B. (2003). Zinc and copper levels in cord blood and mother’s serum Original Article. Türk Pediatri Arşivi, Cilt: 38 Sayı: 1. https://ajindex.com/articles/1437833

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...