Journals / Atmospheric Pollution Research / 2020 / Cilt: 11 - Sayı: 5

Investigation of indoor air quality in the ventilated ice rink arena

Pages
903–908
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Results show that the mean concentration of bacteria aerosol was lower whenthe VS was active.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The indoor air quality (IAQ) of an ice rink, located in the Upper Silesia Region of Southern Poland, was assessedduring the winter holidays.
📊
Key Findings & Data:Concentration levels ofairborne bacteria were above 103CFU/m³, both when the VS system was turned off(990 CFU/m3) and when itwas operational (740 CFU/m3).
💡
Conclusion & Impact:Results show that the mean concentration of bacteria aerosol was lower whenthe VS was active.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Özet

The indoor air quality (IAQ) of an ice rink, located in the Upper Silesia Region of Southern Poland, was assessedduring the winter holidays. Ice rinks are characterized by unusual conditions and multiple sources of pollution.This study evaluated the relative importance of the ventilation system (VS) for maintaining the indoor micro-environment in the ice rink. A preliminary investigation of the concentration levels and characteristics of theindoor and outdoor bacterial aerosol was conducted. Bacterial concentration levels were obtained using a six-stage Andersen cascade impactor. Bioaerosol particles, captured on nutrient media on Petri dishes, werequantitatively evaluated and qualitatively identified using a GEN III Biolog system. Concentration levels ofairborne bacteria were above 103CFU/m³, both when the VS system was turned off(990 CFU/m3) and when itwas operational (740 CFU/m3). Results show that the mean concentration of bacteria aerosol was lower whenthe VS was active. There was a dominance of Gram-positive cocci identified in the indoor environment, whichindicates that most of the bacteria present in the studied building were relatively fresh and mostly of human-origin. These data were used to estimate the ice rink exposure dose (IRED) of bioaerosols for building personneland for children. The highest value of IRED over the study period was obtained for children (220 CFU kg−1).

🔖

Cite This Article

BRAGOSZEWSKA, E., PALMOWSKA, A., BİEDRON, I. (2020). Investigation of indoor air quality in the ventilated ice rink arena. Atmospheric Pollution Research, Cilt: 11 - Sayı: 5, 903–908. https://ajindex.com/articles/142853

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. Brągoszewska, E., Mainka, A., Pastuszka, J.S., 2016. Bacterial aerosols in an urban nur-sery school in Gliwice, Poland: a case study. Aerobiologia 32, 469–480.https://doi.org/10.1007/s10453-015-9419-x. Brągoszewska, Ewa, Mainka, A., Pastuszka, J., Lizończyk, K., Desta, Y., 2018. Assessmentof bacterial aerosol in a preschool, primary school and high school in Poland.Atmosphere 9, 87.https://doi.org/10.3390/atmos9030087. Brągoszewska, E., Biedroń, I., 2018. Indoor air quality and potential health risk impacts ofexposure to antibiotic resistant bacteria in an office rooms in southern Poland. Int. J.Environ. Res. Publ. Health.https://doi.org/10.3390/ijerph15112604.
  2. Burroughs, H.E., Hansen, S.J., Wagner, A., Gossauer, E., Moosmann, C., Gropp, T.,Leonhart, R., Mehling, H., Cabeza, L.F., 2011. Managing Indoor Air Quality,fifth ed.Energy and Buildings. Canha, N., Almeida, S.M., Freitas, M.D.C., Wolterbeek, H.T., 2015. Assessment ofbioaerosols in urban and rural primary schools using passive and active samplingmethodologies. Arch. Environ. Protect. 41, 11–22. https://doi.org/10.1515/aep-2015-0034.
  3. Chow, T.T., Yang, X.Y., 2004. Ventilation performance in operating theatres againstairborne infection: review of research activities and practical guidance. J. Hosp.Infect.https://doi.org/10.1016/j.jhin.2003.09.020. Dumała, S.M., Dudzińska, M.R., 2013. Microbiological indoor air quality in Polishschools. Annual Set The Environment Protection 15, 231–244.
  4. Fang, Z., Ouyang, Z., Zheng, H., Wang, X., Hu, L., 2007. Culturable airborne bacteria inoutdoor environments in Beijing, China. Microb. Ecol. 54, 487–496.https://doi.org/10.1007/s00248-007-9216-3. Gołofit-Szymczak, M., Górny, R.L., 2010. Bacterial and fungal aerosols in air-conditionedoffice buildings in Warsaw, Poland-the winter season. Int. J. Occup. Saf. Ergon. 16,465–476. Górny, R.L., Dutkiewicz, J., 2002. Bacterial and fungal aerosols in indoor environment inCentral and Eastern European countries. Ann. Agric. Environ. Med.: AAEM 9, 17–23.
  5. Guerra, B., Fischer, J., Helmuth, R., 2014. An emerging public health problem: acquiredcarbapenemase-producing microorganisms are present in food-producing animals,their environment, companion animals and wild birds. Vet. Microbiol.https://doi.org/10.1016/j.vetmic.2014.02.001.
  6. Guo, H., Lee, S.C., Chan, L.Y., 2004. Indoor air quality in ice skating rinks in Hong Kong.Environ. Res.https://doi.org/10.1016/S0013-9351(03)00116-6.
  7. Hajian, M., Mohaghegh, S., 2015. Indoor air pollution in e