Journals / Journal of Thermal Engineering / 2026 / Volume: 8 Issue: 2

An application of conventional and advanced exergy approaches on a R41/R1233ZD(E) cascade refrigeration system under optimum conditions

Cenker Aktemur(Department of Mechanical Engineering, Kocaeli University, Umuttepe Campus, 41380 Kocaeli, Turkey)0000-0001-9045-832X
Servet Giray Hacıpasaoglu(Department of Mechanical Engineering, Kocaeli University, Umuttepe Campus, 41380 Kocaeli, Turkey)0000-0001-6698-3562
Pages
—
Publication Date
2022-03-11
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results indicate that the CRS’s exergy efficiency, which can be determined based on conventional exergy analysis, is only 36%.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Painstaking adjustment of an optimum low-temperature cycle (LTC) condenser temperature allows cascade refrigeration system (CRS) to operate at maximum performance.
📊
Key Findings & Data:This study exhibits an original approach because, for the first time, advanced exergy analysis is implemented under an optimum LTC condenser temperature of CRS operating with R41/R1233zd(E) as an environmentally-friendly refrigerant pair.
💡
Conclusion & Impact:The results indicate that the CRS’s exergy efficiency, which can be determined based on conventional exergy analysis, is only 36%.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Cascade Refrigeration System · Advanced Exergy Analysis · Conventional Exergy Analysis

Abstract

Painstaking adjustment of an optimum low-temperature cycle (LTC) condenser temperature allows cascade refrigeration system (CRS) to operate at maximum performance. This study exhibits an original approach because, for the first time, advanced exergy analysis is implemented under an optimum LTC condenser temperature of CRS operating with R41/R1233zd(E) as an environmentally-friendly refrigerant pair. Under the auspices of advanced exergy analysis, there is endogenous exergy destruction of 50.43% and exogenous exergy destruction of 49.57% within total exergy destruction. It is pointed out that the interactions between the CRS components (external irreversibilities) are partly less than exergy destruction that occurs within components (internal irreversibilities). The avoidable part within total exergy destruction, which is greater than the unavoidable part, indicates that components have a high improvement potential with a value of 56.31%. Furthermore, LTC compressor depends significantly on other components, as it has the largest exogenous part of exergy destruction with 75.82%. The results indicate that the CRS’s exergy efficiency, which can be determined based on conventional exergy analysis, is only 36%. However, this increases to 68% with the improvements needed for the components.

🔖

Cite This Article

Aktemur, C., Hacıpasaoglu, S. G. (2022). An application of conventional and advanced exergy approaches on a R41/R1233ZD(E) cascade refrigeration system under optimum conditions. Journal of Thermal Engineering, Volume: 8 Issue: 2. https://doi.org/10.18186/thermal.1080196

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. The article references can be accessed from the.pdf file.
  2. The article references can be accessed from the.pdf file.