Journals / Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi / 2026 / Cilt: 22 Sayı: 2

Clinical use of PGE2 (dinoprostone) and cervical ripening balloon catheter during delivery induction in patients with a Bishop score of ≤4 with vertex presentation

Bishop Skoru ≤4 Olan Vertex Geliş Hastalarda Doğum İndüksiyonunda PGE2(dinoproston) ve Servikal Olgunlaştırıcı Balon Kateterin Klinik Kullanımdaki Yeri

Hakkı Şerbetçi(ESKISEHIR OSMANGAZI UNIVERSITY)0000-0001-6536-8138
Melih Velipaşaoğlu(ESKİŞEHİR OSMANGAZİ ÜNİVERSİTESİ)0000-0003-4070-3432
Mete Tanır(ESKISEHIR OSMANGAZI UNIVERSITY)0000-0003-2980-630X
Pages
158–162
Publication Date
2025-06-30
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this regard, more work needs to be done with the patient.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: We aimed to compare the clinical use of PGE2 (dinoprostone) and cervical ripening balloon catheter for delivery induction in patients with a Bishop score of ≤4 with vertex presentation.
📊
Key Findings & Data:Material and Methods: This study was retrospectively conducted and included the induction of labor between January 2014 and January 2017 at Eskisehir Osmangazi University, Department of Obstetrics and Gynecology.
💡
Conclusion & Impact:In this regard, more work needs to be done with the patient.
🔬Design:Klinik Araştırma
📍Scope:2014 Verileri
⚙️Variables:PGE2 · Çift balon katater · doğum indüksiyonu

Abstract

Purpose: We aimed to compare the clinical use of PGE2 (dinoprostone) and cervical ripening balloon catheter for delivery induction in patients with a Bishop score of ≤4 with vertex presentation. Material and Methods: This study was retrospectively conducted and included the induction of labor between January 2014 and January 2017 at Eskisehir Osmangazi University, Department of Obstetrics and Gynecology. There was a total of 60 patients in the study and 30 patients were given dinoprostone and 30 patients were given birth by double balloon catheter. We compared the clinical results of the patients. Multivariable regressions were used to identify odds of induction success. Results: There was no significant difference between the demographic characteristics of the patients. When the clinical results of the patients were compared, there was no difference between the vaginal delivery rate and the delivery time between the two groups. The duration of active labor in the balloon catheter group was statistically significantly longer (p = 0.036). The amount of postpartum hemorrhage in the balloon catheter group was also significantly higher (p = 0.008). Conclusion: The ideal agent to be used in cervical pregnancy is still a controversial issue. In this regard, more work needs to be done with the patient.

Özet

Amaç: Bu çalışmada Bishop skoru ≤4 olan vertex geliş hastalarda doğum indüksiyonunda PGE2(dinoproston) ve servikal olgunlaştırıcı balon kateterin klinik kullanımdaki yerini karşılaştırmak amaçlandı. Materyal ve Metod: Bu çalışma retrospektif yapılmış olup Eskişehir Osmangazi Üniversitesi Kadın hastalıkları ve Doğum Anabilim Dalında Ocak 2014 -Ocak 2017 tarihleri arasında yapılan doğum indüksiyonlarını kapsamaktadır. Çalışmada toplam 60 hasta mevcut olup 30 hastaya dinoproston ile 30 hastata ise çift balon katater ile doğum indüksiyonu yapılmıştır. Hastaların klinik sonuçları karşılaştırılmıştır. İndüksiyon sonucuna etki edebilecek faktörler lojistik regresyon modeli ile analiz edildi. Bulgular: Hastaların demografik özellikleri arasında anlamlı fark yoktu. Hastaların klinik sonuçları karşılaştırıldığında ise her iki grup arasında vajinal doğum oranı ve doğum süreleri arasında fark saptanmadı. Balon katater grubunda aktif doğum eylemi süresi istatistiksel olarak anlamlı ölçüde uzun saptandı (p=0,036). Balon katater grubunda postpartum kanama miktarı anlamlı ölçüde fazlaydı (p=0,008). Sonuç: Servikal olgulaşmada kullanılacak ideal ajan hala güncel bir tartışma konusudur. Bu konuda daha fazla hastayla yapılacak çalışmalara ihtiyaç duyulmaktadır.

🔖

Cite This Article

Şerbetçi, H., Velipaşaoğlu, M., Tanır, M. (2025). Clinical use of PGE2 (dinoprostone) and cervical ripening balloon catheter during delivery induction in patients with a Bishop score of ≤4 with vertex presentation. Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi, Cilt: 22 Sayı: 2, 158–162. https://doi.org/10.38136/jgon.1569733

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Referanslar