Journals / Balkan Medical Journal / 2012 / Cilt: 2012 Sayı: 4

Severe Valvular Regurgitation: An Unexpected Complication During Transapical Aortic Valve Implantation Treated Successfully with the “Valve-in-Valve” Procedure

Pages
444–446
Publication Date
2012-04-01
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

During a follow-up time of 2,5 years no further problems occurred.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Severe symptomatic aortic stenosis (AS) in a multimorbid 77 year old female was treated with transapical aortic valve implantation with a 23 mm Edwards Sapien valve.
📊
Key Findings & Data:Severe valvular regurgitation following implantation, probably due to structural valve failure, was treated successfully with a second valve-in- valve implantation.
💡
Conclusion & Impact:During a follow-up time of 2,5 years no further problems occurred.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:TAVI · aortic regurgitation · complication

Abstract

Severe symptomatic aortic stenosis (AS) in a multimorbid 77 year old female was treated with transapical aortic valve implantation with a 23 mm Edwards Sapien valve. Severe valvular regurgitation following implantation, probably due to structural valve failure, was treated successfully with a second valve-in- valve implantation. During a follow-up time of 2,5 years no further problems occurred.

🔖

Cite This Article

Kavukcu, E., Burgazlı, K. M., Chasan, R., Kavukçu, E., Bilgin, M., Erdoğan, A. (2012). Severe Valvular Regurgitation: An Unexpected Complication During Transapical Aortic Valve Implantation Treated Successfully with the “Valve-in-Valve” Procedure. Balkan Medical Journal, Cilt: 2012 Sayı: 4, 444–446. https://doi.org/10.5152/balkanmedj.2012.040

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Webb JG, Pasupati S, Humphries K, Thompson C, Altwegg L, Moss R, et al. Percutaneous transarterial aortic valve replacement in selected high risk patients with aortic stenosis. Circulation 2007;116:755-63. [CrossRef]
  2. Walther T, Simon P, Dewey T, Wimmer-Greinecker G, Falk V, Kasimir MT, et al. Transapical minimally invasive aortic valve implantation: multicenter experience. Circulation 2007;116:240-5. [CrossRef]
  3. Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case descrip- tion. Circulation 2002;106:3006-8. [CrossRef]
  4. Ducrocq G, Francis F, Serfaty JM, Himbert D, Maury JM, Pasi N, et al. Vascular complications of transfemoral aortic valve implan- tation with the Edwards SAPIEN prosthesis: incidence and im- pact on outcome. EuroIntervention 2010;5:666-72. [CrossRef]
  5. Van Mieghem NM, Nuis RJ, Piazza N, Apostolos T, Ligthart J, Schul- tz C, et al. Vascular complications with transcatheter aortic valve implantation using the 18 Fr Medtronic Core Valve System: the Rot- terdam experience. EuroIntervention 2010;5:673-9. [CrossRef]
  6. Sinhal A, Altwegg L, Pasupati S, Humphries KH, Allard M, Mar- tin P, et al. Atrioventricular block after transcatheter balloon ex- pand- able aortic valve implantation. JACC Cardiovasc Interv 2008;1:305-9. [CrossRef]
  7. Masson JB, Kovac J, Schuler G, Ye J, Cheung A, Kapadia S, et al. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv 2009;2:811-20. [CrossRef]
  8. Grube E, Schuler G, Buellesfeld L, Gerckens U, Linke A, Wenaweser P, et al. Percutaneous aortic valve replacement for severe aortic ste- nosis in high-risk patients using the second- and current third-gener- ation self-expanding CoreValve prosthesis: device success and 30- day clinical outcome. J Am Coll Cardiol 2007;50:69-76. [CrossRef]
  9. Rodes-Cabau J, Dumont E, Doyle D. Valve in valve for the treat- ment of paravalvular leaks following transcatheter aortic valve im- plantation. Catheter Cardiovasc Interv 2009;74:1116-9. [CrossRef]
  10. Sherif MA, Abdel-Wahab M, Stöcker B, Geist V, Richardt D, Tölg R, et al. Anatomic and procedural predictors of paravalvular aor- tic regurgitation after implantation of the Medtronic CoreValve bioprosthesis. J Am Coll Cardiol 2010;56:1623-9. [CrossRef]
  11. Al-Attar N, Ghodbane W, Himbert D, Rau C, Raffoul R, Messika- zeitoun D, et al. Unexpected complications of transapical aortic valve implantation. Ann Thorac Surg 2009;88:90-4. [CrossRef]
  12. Schaff HV. Transcatheter aortic-valve implantation--at what price? N Engl J Med 2011;364:2256-8. Balkan Med J 2012; 29: 444-6
  13. Severe Valvular Regurgitation