Different Cause of Inappropriate ICD shocks

İmplante Edilebilir Kardiyoverter Defibrilatörde Farklı Uygunsuz Şok Nedeni

Kerem Can Yılmaz(Başkent Üniversitesi Tıp Fakültesi Hastanesi, Kardiyoloji Anabilim Dalı, Ankara)
Begüm Yetiş(Başkent Üniversitesi Tıp Fakültesi Hastanesi, Kardiyoloji Anabilim Dalı, Ankara)
İlyas Atar(Başkent Üniversitesi Tıp Fakültesi Hastanesi, Kardiyoloji Anabilim Dalı, Ankara)
Bülent Özin(Başkent Üniversitesi Tıp Fakültesi Hastanesi, Kardiyoloji Anabilim Dalı, Ankara)
Pages
183–185
Publication Date
2015-05-01
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
🔖

Cite This Article

Yılmaz, K. C., Yetiş, B., Atar, İ., Özin, B. (2015). Different Cause of Inappropriate ICD shocks. Abant Tıp Dergisi, Cilt: 4 Sayı: 2, 183–185. https://doi.org/10.5505/abantmedj.2015.20591

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Block M, Breithardt G. Long term follow -up and clinical results of implantable caridoverter - defibrillators. Cardiac Electrophysiology -From Cell to Bedside. Phileadelphia: W.B. Saunders 1995; 1412 -1425
  2. Bourke JP, Turkington D, Thomas G, McComb JM, Tynan M. Florid. psychopathology in patients receiving shocks from implanted cardioverterdefi brillators. Heart 1997;78(6):581 –583
  3. Weber M, Block M, Brunn J, Bänsch D, Böcker D, Hammel D, Gietzen F, Breithardt G. Inadequate therapies with implantable cardioverter defibrillators:Incidence, eitology, predictive factors and preventive strategies. Z Kardiol 1996; 85:809 -819
  4. Rosenquist M, Bayer T, Block M, den Dulk K, Minten J, Lindemans F. Adverse events with transvenous implantable caridoverter - defibrillators:A prospective multicenter study. Circulation 1998; 98:663 -670
  5. Nunain SO, Roelke M, Trouten T, Osswald S, Kim YH, Sosa -Suarez G, Brooks DR, McGovern B, Guy M, Torchiana DF. Limitations and late complications of third generation automatic cardioverter -defibrillators. Circulation 1995; 91:2204 -2213
  6. Chan NY, Wai -Ling Ho L. Inappropriate implantable cardioverter defibrillator shock due to external alternating current leak: Report of two cases. Europace 2005; 7:193 - 196
  7. Barakpour H, Emkanjoo Z, Alizadeh A, Sadr - Ameli MA. Inappropriate Shock Delivered By Implantable Cardioverter Defibrillator - Cardiac Resynchronization Therapy (CRT -İKD ) Due To Myopotential Oversensing. Indian Pacing Electrophysiol J. 2009; 9:71 -74
  8. Dyrda K, Khairy P.Implantable rhythm devices and electromagnetic interference: myth or reality? Expert Rev Cardiovasc Ther, 2008;6:823 - 832
  9. Sabaté X, Moure C, Nicolás J, Sedó M, Navarro X. Washing machine associated 50 Hz detected as ventricular fibrillation by an implanted cardioverter defibrillator. Pacing Clin Electrophysiol. 2001; 24:1281 -1283
  10. Lee SW, Moak JP, Lewis B. Inadvertent detection of 60 -Hz alternating current by an implantable cardioverter defibrillator. Pacing Clin Electrophysiol. 2002; 25:518 -519