Journals / Düzce Tıp Fakültesi Dergisi / 2026 / Volume: 16 Issue: 2

Changes Of Optical Quality After Blinking

GÖZ KIRPMA SONRASI OPTİK KALİTEDEKİ DEĞİŞİKLİKLER

Kuddusi Kılıç(Erciyes Üniversitesi, Tıp Fakültesi, Göz Hastalıkları AD, Kayseri)
Abdullah Özkırış(Acıbadem Hastanesi, Göz Hastalıkları Kliniği, Kayseri)
Tülay Karacan Erşekerci(Darende Hulusi Efendi Devlet Hastanesi, Malatya)
Nilüfer İlhan(Mustafa Kemal Üniversitesi, Tayfur Ata Sökmen Tıp Fakültesi, Göz Hastalıkları AD, Hatay)
Pages
—
Publication Date
2014-07-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: A layer of tear film in normal subjects remained stable up to 10 seconds ensuresthat the optical quality is good

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: To investigate changes in the optical quality of normal eyes associated with blinking.Methods: Between the ages of 18-46 (30.43 ± 9:54), ranging from 60 healthy subjects (28 male,32 female) were included in the study.
📊
Key Findings & Data:Process postblink aberration measurements of the patientsafter 1 second (group 1) and 10 seconds (group 2) were made with Nidek-OPD SCAN.Results: Between group 1 and group 2, no significant difference was detected in the high-orderand spherical aberrations (p>0.05).
💡
Conclusion & Impact:Conclusion: A layer of tear film in normal subjects remained stable up to 10 seconds ensuresthat the optical quality is good
🔬Design:Article
📍Scope:Comprehensive Sample
⚙️Variables:Blinking · optical quality · tear film

Abstract

Purpose: To investigate changes in the optical quality of normal eyes associated with blinking.Methods: Between the ages of 18-46 (30.43 ± 9:54), ranging from 60 healthy subjects (28 male,32 female) were included in the study. Process postblink aberration measurements of the patientsafter 1 second (group 1) and 10 seconds (group 2) were made with Nidek-OPD SCAN.Results: Between group 1 and group 2, no significant difference was detected in the high-orderand spherical aberrations (p>0.05). Conclusion: A layer of tear film in normal subjects remained stable up to 10 seconds ensuresthat the optical quality is good

Özet

Amaç: Normal gözlerde kırpma ile ilişkili optik kalitedeki değişiklikleri incelemek.Yöntem: Yaşları 18-46 arasında (30.43±9.54) değişen sağlıklı 60 olgu (28 erkek, 32 kadın)çalışma kapsamına alındı. Olguların aberasyon ölçümleri göz kırpma işleminden 1 saniye sonra(grup 1 ) ve 10 saniye sonra (grup 2) Nidek-OPD SCAN cihazı ile yapıldı. Bulgular: Grup 1 ile grup 2 arasında high-order ve sferik aberasyonlar açısından fark tespitedilmedi (p>0.05). Sonuç: Normal bireylerde göz yaşı film tabakası 10 saniyeye kadar stabil kalarak optik kaliteniniyi olmasını sağlar

🔖

Cite This Article

Kılıç, K., Özkırış, A., Erşekerci, T. K., İlhan, N. (2014). Changes Of Optical Quality After Blinking. Düzce Tıp Fakültesi Dergisi, Volume: 16 Issue: 2. https://ajindex.com/articles/1346812

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Nemeth J, Erderlyi B, Csakany B, et al. High-speed videokeratographic measurement of tear film build-up time. Invest ophthalmol Vis Sci. 2002;43:1783-1790.
  2. Montes-Mico R, Alio JL, Munoz G, et al. Temporal changes in optical quality of air-tear film interface at anterior cornea after blink. Invest Ophthalmol Vis Sci. 2004;45(6):1752-1757.
  3. Koh S, Tung C, Aquavella J, Yadav R, Zavislan J, Yoon G. Simultaneous measurement of tear film dynamics using wavefront sensor and optical coherence tomography. Invest Ophthalmol Vis Sci. 2010;51(7):3441-3448.
  4. Nemeth J, Erderlyi B, Csakany B, et al. Corneal topography changes after a 15 second pause blink. J Cat Ref Surg. 2001;27:589-592.
  5. Montes-Mico R, Caliz A, Alio JL. Wavefront analysis of higher-order aberrations in dry eye patients. J Ref Surg. 2004;20(3):243-247.
  6. Montes-Mico R, Caliz A, Alio JL. Changes in ocular aberrations after artificial tears instillation in dry eye patients. J Cat Ref Surg. 2004;30(8):1649-1652.
  7. Monte´s-Mico´ R, Alio´ JL, Mun˜oz G, Pe´rez-Santonja JJ, Charman WN. Postblink changes in total and corneal ocular aberrations. Ophthalmology. 2004;111:758–767.
  8. Buehren T, Collins MJ, İskender DR, et al. The stability of corneal topography in the postblink interval. Cornea. 2001;20:826-833.
  9. Morgan PB, Soh MP, Efron N. Potential applications of ocular thermography. Optom Vis Sci. 1993;70:568-576.
  10. Hofer H, Artal P, Singer B, Aragon JL, Williams DR. Dynamics of the eye’s wave aberration. J Opt Soc Am A Opt Image Sci Vis. 2001;18:497–506.
  11. Iskander DR, Collins MJ, Morelande MR, Zhu M. Analyzing the dynamic wavefront aberrations in the human eye. IEEE Trans Biomed Eng. 2004;51:1969–1980.
  12. Zhu M, Collins MJ, Iskander DR. Microfluctuations of wavefront aberrations of the eye. Ophthalmic Physiol Opt. 2004;24:562–571.
  13. Ninomiya S, Fujikado T, Kuroda T, et al. Changes of ocular aberration with accommodation. Am J Ophthalmol. 2002;134:924–926.
  14. Cheng H, Barnett JK, Vilupuru AS, et al. A population study on changes in wave aberrations with accommodation. J Vision. 2004;4:272–280. İnci ve ark.
  15. Buehren T, Collins MJ, İskender DR, et al. The stability of corneal topography in the postblink interval. Cornea. 2001;20:826-833.