Journals / Uludağ Üniversitesi Mühendislik Fakültesi Dergisi / 2019 / Cilt: 24 Sayı: 3

THERMOPHYSIOLOGIAL COMFORT PROPERTIES OF DIFFERENT CLOTHES AFTER AN ACTIVITY PERIOD

Bir Aktivite Periyodu Sonrası Farklı Giysilerin Termofizyolojik Konfor Özellikleri

Esra Taştan Özkan(BİTLİS EREN ÜNİVERSİTESİ)0000-0001-8950-6048
Binnaz Kaplangiray(ULUDAĞ ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ)0000-0002-1296-9092
Ufuk Şekir(ULUDAĞ ÜNİVERSİTESİ, TIP FAKÜLTESİ)0000-0003-2735-8697
Pages
1–12
Publication Date
2019-12-31
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed that the lowest waist microclimate temperature value was seen in TS tencel single jersey fabric like the other three body regions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study five different knitted sport clothes were tested in a wear trial test with ten men subject.
📊
Key Findings & Data:After the activity, subjects were included in a rest period of 20 minutes.
💡
Conclusion & Impact:The results showed that the lowest waist microclimate temperature value was seen in TS tencel single jersey fabric like the other three body regions.
🔬Design:Araştırma Makalesi
📍Scope:Comprehensive Sample
⚙️Variables:Giysi Konforu · Mikroklima Sıcaklık · Mikroklima Bağıl Nem

Abstract

In this study five different knitted sport clothes were tested in a wear trial test with ten men subject. After the activity, subjects were included in a rest period of 20 minutes. In this period, microclimate temperature and relative humidity values were measured with a datalogger from four body regions (chest, abdomen, back and waist). The results showed that the lowest waist microclimate temperature value was seen in TS tencel single jersey fabric like the other three body regions. On the contrary to chest and back regions, the abdomen microclimate temperature values increase during the relaxing period. Also the lowest microclimate temperature values were seen in abdomen region. On the other hand the highest microclimate relative humidity values were seen in abdomen region ( 93-96 %).

Özet

Bu çalışmada beş farklı spor giysi belirli bir antreman programında 10 erkek deneğe giydirilmiş ve aktivite sonrasındaki 20 dakikalık dinlenme periyodunda 4 farklı vücut bölümünün (göğüs, karın, sırt ve bel) mikroklima sıcaklık ve bağıl nem değerlerinin ortalamaları verilmiştir. Ayrıca dinlenme periyodu boyunca nabız ve maksimum oksijen tüketimi değerleri nabız ölçer polar saat ve kardiyo solunum fonksiyonları ölçüm cihazı kullanılarak ölçülmüştür. Sonuç olarak en düşük mikroklima sıcaklık değeri diğer üç bölgede olduğu gibi bel bölgesinde de TS kodlu tencel süprem kumaş numunesinde görülmüştür. Göğüs ve sırt bölgelerinden farklı olarak karın mikroklima sıcaklık değerlerinin dinlenme periyodu boyunca arttığı görülmüştür. Ayrıca en düşük mikroklima sıcaklık değerleri karın bölgesinde görülmüştür. Diğer yandan en yüksek mikroklima bağıl nem değerleri karın bölgesinde görülmüştür (%93-96).

🔖

Cite This Article

Özkan, E. T., Kaplangiray, B., Şekir, U. (2019). THERMOPHYSIOLOGIAL COMFORT PROPERTIES OF DIFFERENT CLOTHES AFTER AN ACTIVITY PERIOD. Uludağ Üniversitesi Mühendislik Fakültesi Dergisi, Cilt: 24 Sayı: 3, 1–12. https://doi.org/10.17482/uumfd.548069

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (19)

  1. Afzal, A., Hussain, T., Mohsin, M., Rasheed, A. and Ahmad, S.( 2014) Statistical models for predicting the thermal resistance of polyester/cotton blended interlock knitted fabric, International Journal of Thermal Sciences, 85, 40-46. https://doi.org/10.1016/j.ijthermalsci.2014.06.016.
  2. Atasağun, H.G., Öner, E., Okur, A., Beden, A.R.A. (2015) Comprehensive study on the general performance properties of Viloft-blended knitted fabrics, The Journal of The Textile Institute, 106(5), 523-535. https://doi.org/10.1080/00405000.2014.929270
  3. Brazaitis, M., Kamandulis, S., Skurvydas, A., Daniusevičiūtė, L.(2010) The effect of two kinds of T-shirts on physiological and psychological thermal responses during exercise and recovery, Applied Ergonomics, 42(1), 46-51. https://doi.org/10.1016/j.apergo.2010.04.001
  4. Ciesielska, I.L., Masajtis, J. (2008) The preliminary studies of influence of garments on human beings corona discharge, International Journal of Clothing Science and Technology, 20(5), 299-316. doi: 10.1108/09556220810898917
  5. Cubric, I.S., Skenderi, Z., Mihelic´-Bogdanic, A., Andrassy, M. (2012) Experimental study of thermal resistance of knitted fabrics, Experimental Thermal and Fluid Science, 38, 223-228. https://doi.org/10.1016/j.expthermflusci.2011.12.010
  6. Ha, M., Tokura, H., Yanai, Y., Moriyama, T., Tsuchiya, N. (1999) Combined effects of fabric air permeability and moisture absorption on clothing microclimate and subjective sensation during intermittent exercise at 27 degrees C, Ergonomics, 42(7), 964-79. https://doi.org/10.1080/001401399185243
  7. Kaplan S, Okur A. (2012) Thermal comfort performance of sports garments with objective and subjective measurements, Indian Journal of Fibre and Textile Research, 37(1), 46-54. http://hdl.handle.net/123456789/13685
  8. Onofrei, E., Rocha, AM., Catarino, A. (2011) The Influence of Knitted Fabrics Structure on the Thermal and Moisture Management Properties, Journal of Engineered Fibres and Fabrics, 6 (4), 10-22. https://doi.org/10.1177/155892501100600403
  9. Özkan, T.E., Meriç, B. (2015) Thermophysiological comfort properties of different knitted fabrics used in cycling clothes, Textile Research Journal, 85(1), 62-70. https://doi.org/10.1177/0040517514530033
  10. Pac, M. J., Bueno, M. A. and Renner, M. 2001. Warm-cool feeling relative to tribological properties of fabrics, Textile Research Journal, 71(9), 806-812. https://doi.org/10.1177/004051750107100910
  11. Purvis, A., Tunstall, H. (2004) Effects of sock type on foot skin temperature and thermal demand during exercise, Ergonomics, 47(15), 1657-1668. https://doi.org/10.1080/00140130412331290880
  12. Saville, B. P. (1999) Physical testing of textiles, Woodhead Publishing Ltd.
  13. Sullivan, P.J., Mekjavik, L.B. (1992) Temperature and humidity within the clothing microenvironment. Aviat Space Environ Med, 63, 186-192.
  14. Uçar, N. and Yilmaz, T. 2004. Thermal Properties of 1×1, 2×2 and 3×3 rib knit fabrics. Fibers and Textiles in Eastern Europe, 12(3), 34-38.
  15. Wong, A.S.W., Li, Y. (2004) Relationship between thermophysiological responses and psychological thermal perception during exercise wearing aerobic wear, Journal of Thermal Biology, 29 (7-8), 791-796. https://doi.org/10.1016/j.jtherbio.2004.08.057
  16. Yanılmaz, M., Kalaoğlu, F.(2012) Investigation of wicking, wetting and drying properties of acrylic knitted fabrics, Textile Research Journal, 82(8), 820–831. https://doi.org/10.1177/0040517511435851
  17. Atasağun, H.G., Öner, E., Okur, A., Beden, A.R.A. (2015) Comprehensive study on the general performance properties of Viloft-blended knitted fabrics, The Journal of The Textile Institute, 106(5), 523-535. https://doi.org/10.1080/00405000.2014.929270
  18. Ciesielska, I.L., Masajtis, J. (2008) The preliminary studies of influence of garments on human beings corona discharge, International Journal of Clothing Science and Technology, 20(5), 299-316. doi: 10.1108/09556220810898917
  19. Özkan, T.E., Meriç, B. (2015) Thermophysiological comfort properties of different knitted fabrics used in cycling clothes, Textile Research Journal, 85(1), 62-70. https://doi.org/10.1177/0040517514530033