⚡ TL;DR(Too Long; Didn't Read)

During the testing the values are measured by PZ4000 power analyzer; the single layer winding motor has shown high efficiency while the double layer winding motor has proven better performance about harmonics

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Stator windings of the asynchronous motors, are important parts effecting their performances.
📊
Key Findings & Data:In this study, stators of 36 slots, 4 poles, 1,1 kW, 90S-4 type two asynchronous motors are wound as single and double layer windings.
💡
Conclusion & Impact:During the testing the values are measured by PZ4000 power analyzer; the single layer winding motor has shown high efficiency while the double layer winding motor has proven better performance about harmonics
🔬Design:Makale
📍Scope:Comprehensive Sample
⚙️Variables:Asenkron motor · Stator sargıları · Asenkron motorun invertörle beslenmesi

Abstract

Stator windings of the asynchronous motors, are important parts effecting their performances. In this study, stators of 36 slots, 4 poles, 1,1 kW, 90S-4 type two asynchronous motors are wound as single and double layer windings. The motors are fed by PWM inverter supply and tested. During the testing the values are measured by PZ4000 power analyzer; the single layer winding motor has shown high efficiency while the double layer winding motor has proven better performance about harmonics

Özet

Asenkron motorların stator sargıları, motor performansını etkileyen en önemli kısımlarından biridir. Bu çalışmada, 36 oluklu, 4 kutuplu, 1,1 kW’lık NM 90S-4 tipi iki adet motordan birisinin statoru tek tabakalı, diğerinin statoru ise iki tabakalı olarak sarılmıştır. Motorlar PWM bir invertörle beslenerek deneyleri yapılmıştır. Yapılan deneyler süresince gerekli değerler PZ4000 güç analizörü ile ölçülmüş; tek tabakalı sargılı motorun veriminin yüksek olduğu ancak, harmonikler bakımından da iki tabakalı sargılı motorun daha iyi olduğu tespit edilmiştir.

🔖

Cite This Article

Korkmaz, Y. (2008). Effects of the Stator Winding Structure of Asynchronous Motors Fed by PWM Inverter on the Performance of the Motor. Politeknik Dergisi, Cilt: 11 Sayı: 2, 123–128. https://ajindex.com/articles/1303084