Journals / Mugla Journal of Science and Technology / 2026 / Volume: 12 Issue: 1

Seismic Fragility Curves of a Friction Pendulum Base Isolated Structure Under Near-Fault Ground Motion Data

Zubair Sediqi(graduate school of natural and applied sciences)0000-0003-3026-8529
Ebru Harmandar(MUĞLA ÜNİVERSİTESİ)0000-0001-9802-2993
Pages
—
Publication Date
2026-06-30
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results indicate that the maximum inter-story drift ratio remains within acceptable limits without exceeding the thresholds for extensive or collapse damage states.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Base isolation is widely recognized as one of the most effective seismic protection strategies for buildings, particularly in earthquake-prone areas.
📊
Key Findings & Data:For the seismic performance assessment of the structure, Incremental dynamic analysis is performed for each ground motion dataset.
💡
Conclusion & Impact:The results indicate that the maximum inter-story drift ratio remains within acceptable limits without exceeding the thresholds for extensive or collapse damage states.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Fragility curves · Base isolated structures · Friction pendulum bearings

Abstract

Base isolation is widely recognized as one of the most effective seismic protection strategies for buildings, particularly in earthquake-prone areas. In this study, a ten-story seismically-isolated structure with curved surface friction isolators (friction pendulum bearings) is analyzed, considering two primary engineering demand parameters: maximum inter-story drift ratio and maximum isolator displacement. A set of near-fault ground motion records containing long-period velocity pulses and higher amplitudes was selected and scaled. For the seismic performance assessment of the structure, Incremental dynamic analysis is performed for each ground motion dataset. The structural response is evaluated based on predefined performance limit states. The results indicate that the maximum inter-story drift ratio remains within acceptable limits without exceeding the thresholds for extensive or collapse damage states. However, the isolator displacement demand reaches all damage state thresholds under near-fault excitations. These findings emphasize the critical role of the isolator displacement capacity in the seismic risk assessment of seismically isolated structures.

🔖

Cite This Article

Sediqi, Z., Harmandar, E., Şadan, B., *, Z. S. (2026). Seismic Fragility Curves of a Friction Pendulum Base Isolated Structure Under Near-Fault Ground Motion Data. Mugla Journal of Science and Technology, Volume: 12 Issue: 1. https://doi.org/10.22531/muglajsci.1865260

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Yadav, K. K. and Gupta, V. K., “Near-fault fling-step ground motions: Characteristics and simulation”, Soil Dynamics and Earthquake Engineering, 101, 90-104, 2017.
  2. Domadzra, Y., Bhandari, M. and Hasan, M., “Seismic response of base-isolated buildings: exploring isolator properties”, Asian Journal of Civil Engineering, 25, 4197-4209, 2024.
  3. Manarbek, S., Study of Base Isolation Systems, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA, PhD Thesis, 2013.
  4. Liu, C., Fang, D. and Yan, Z., “Seismic fragility analysis of base isolated structure subjected to near-fault ground motions”, Periodica Polytechnica Civil Engineering, 65 (3), 768-783, 2021.
  5. Gong, W. and Xiong, S., “Probabilistic seismic risk assessment of modified pseudo-negative stiffness control of a base-isolated building”, Structure and Infrastructure Engineering, 12 (10), 1295-1309, 2016.
  6. Bhandari, M., Bharti, S. D., Shrimali, M. K. and Datta, T. K., “Seismic Fragility Analysis of Base-Isolated Building Frames Excited by Near- and Far-Field Earthquakes”, Journal of Performance of Constructed Facilities, 33 (3), 2019.
  7. Zayas, V.A., Low, S.S. and Mahin, S.A., “A simple pendulum technique for achieving seismic isolation”, Earthquake Spectra, 6 (2), 317-333, 1990.
  8. Turkey Building Earthquake Code (TBEC), Republic of Turkey Ministry of Interior Disaster and Emergency Management Authority, Ankara, Turkey, 2018.
  9. Vamvatsikos, D. and Cornell, C. A., “Incremental dynamic analysis”, Earthquake Engineering & Structural Dynamics, 31 (3), 491-514, 2002.
  10. Sediqi, Z. and Harmandar, E., “Improving the seismic resilience index of a school building”, Natural Hazards, 121 (2), 2397-2417, 2025.
  11. Cimellaro, G. P., Reinhorn, A. M., Bruneau, M. and Rutenberg, A., Multi Dimensional Fragility of Structures: Formulation and Evaluation, Report number: MCEER-06-0002, Multidisciplinary Center for Earthquake Engineering Research, University at Buffalo - the State University of New York, 2006.
  12. Castaldo, P., Palazzo, B. and Della Vecchia, P., “Seismic reliability of base-isolated structures with friction pendulum bearings”, Engineering Structures, 95, 80–93, 2015.