Journals / Middle East Journal of Science / 2026 / Volume: 5 Issue: 1

DOSIMETRIC INVESTIGATION OF RADIOTHERAPY OF SMALL SIZE TUMORS IN RADIOSURGERY DEVICES

Duygu Tunçman Genç(ALTINBAS UNIVERSITY, VOCATIONAL SCHOOL OF HEALTH SERVICES)0000-0002-0929-0441
Eda Mutlu(ALTINBAS UNIVERSITY, VOCATIONAL SCHOOL OF HEALTH SERVICES)0000-0002-3972-7309
Murat Okutan(ISTANBUL UNIVERSITY, INSTITUTE OF ONCOLOGY)0000-0002-2276-631X
Pages
—
Publication Date
2019-06-26
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The EBT3 measurement results indicate that all SRT treatment modalities achieved accurate doses.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In stereotactic radiotherapy, high radiation doses were delivered to tumors using small fields in 1-5 fractions.
📊
Key Findings & Data:In this study, dosimetric measurements of small sized brain tumors irradiated in CONE- based linear accelator (linac) and the volumetric arc therapy (VMAT) linac modalities were performed with EBT3 film. 1,2 and 3 cm diameter tumors were virtually created in Cyberknife head and neck phantom.
💡
Conclusion & Impact:The EBT3 measurement results indicate that all SRT treatment modalities achieved accurate doses.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Stereotactic radiosurgery · Cyberknife · Linac

Abstract

In stereotactic radiotherapy, high radiation doses were delivered to tumors using small fields in 1-5 fractions. It is very important to make sure accuracy of dose and position of given dose in stereotactic radiotherapy. In this study, dosimetric measurements of small sized brain tumors irradiated in CONE- based linear accelator (linac) and the volumetric arc therapy (VMAT) linac modalities were performed with EBT3 film. 1,2 and 3 cm diameter tumors were virtually created in Cyberknife head and neck phantom. Gafchromic EBT3 film was placed into the phantom to evaluate the accuracy of the doses given. The phantom was irradiated with Gafchromic EBT3 film according to treatment plans created in the treatment planning system of two separate devices for each tumor size. Conformity Index (CI) and Homogeneity Index (HI) were calculated for the quality of created treatment plans. The dose distributions calculated in the film and the TPS were compared. When the CI and HI values were examined, the CI and HI values of the cone-based linac device were close to 1. The EBT3 measurement results indicate that all SRT treatment modalities achieved accurate doses. According to results, if a critical organ, such as the brainstem, is located near the tumor and the situation requires a steep dose gradient, the cone-based linac should be used for SRT therapy. This study has shown that on CONE-based linac or VMAT-based linac devices can be used instead of each other in small-area irradiations.

🔖

Cite This Article

Genç, D. T., Mutlu, E., Okutan, M., Demir, B. (2019). DOSIMETRIC INVESTIGATION OF RADIOTHERAPY OF SMALL SIZE TUMORS IN RADIOSURGERY DEVICES. Middle East Journal of Science, Volume: 5 Issue: 1. https://doi.org/10.23884/mejs.2019.5.1.07

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Yazıcı, G., Cengiz, M., et al.,Stereotaktik Vücut Radyoterapisi, Hacettepe Tıp Dergisi, 42 (2011),pp. 74-81
  2. Çağıran Kılçıksız, S., Ermiş, E.,et al.,Görüntü Eşliğinde Stereotaktik Radyoterapi, Okmeydanı Tıp Dergisi, 29(2013), pp. 3-9
  3. Baş, H., Sterotaktik Radyocerrahi için Küçük alanlarda 6 MV Foton Dozimetrisi, Ankara Üniversitesi, Fen Bilimleri Enstitüsü, Yüksek Lisans Tezi, 2005
  4. Kayalılar, N., Cyberknife ve gammaknife tedavilerinde hedef hacim ve normal doku dozlarının karşılaştırılması, Acıbadem Üniversitesi, Sağlık Bilimleri Enstitüsü, Yüksek Lisans Tezi, 2012
  5. Feuvret,L., Noel,G., et al.,Conformity Index: A Review, Int J. Radiation Oncology Biol. Phys., 64(2006),2, pp. 333-342
  6. Feuvret, L., Noel,G.,et al.,Conformal Index and Radiotherapy, CancerRadiother., 8(2004), pp. 2108-19
  7. Das, I., J., Ding, G.,X.,et al., Small fields: Nonequilibrium radiation dosimetry, Medical Physics, 35(2007), 1, pp.206-215
  8. http://amos3.aapm.org/abstracts/pdf/77-22581-312436-91466.pdf
  9. Hsu, Shih-Ming, Lai, Yuan-Chin,et al.,Dosimetric comparison of different treatment modalities for stereotactic radiotherapy,155(2017), 12, 1-11
  10. Jackie Wu, Q-R., Wessels, B.W.,et al., Quality of coverage: Conformity measures for stereotactic radiosurgery, Journal of Applied Clinical Medical Physics, 4(2003),4, pp.374-381.
  11. Yazıcı, G., Cengiz, M., et al.,Stereotaktik Vücut Radyoterapisi, Hacettepe Tıp Dergisi, 42 (2011),pp. 74-81