Journals / Gıda / 1986 / Cilt: 11 - Sayı: 5

The Possibility of the Use of Bread Crumb Firmness Obtained on Extensograph as a Parameter in the Estimation of Staleness of Bread Crumb (Turkish with English Abstract)

Journal
Gıda
Pages
—
Publication Date
1986-10-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In conclusion, the extensogram peak height gave very high and statistically significant correlation coefficient with the Alvetron values at 0.01 level, as being r= 0.810xx (for 1st day), r= 0.828xx (for 2nd day) r= 0.872xx (for 3rd day).

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the possibility of the use of extensograph which has been using in the measurement of dough rheology, to estimate the rheological characteristics of the bread crumb was searched in comparison whit Alvetron as a universal texture measuring instrument.
📊
Key Findings & Data:The research was done on 30 bread samples which are wrapped with polyethylene bags.
💡
Conclusion & Impact:In conclusion, the extensogram peak height gave very high and statistically significant correlation coefficient with the Alvetron values at 0.01 level, as being r= 0.810xx (for 1st day), r= 0.828xx (for 2nd day) r= 0.872xx (for 3rd day).
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, the possibility of the use of extensograph which has been using in the measurement of dough rheology, to estimate the rheological characteristics of the bread crumb was searched in comparison whit Alvetron as a universal texture measuring instrument. The research was done on 30 bread samples which are wrapped with polyethylene bags. After 1, 3 and 5 days, the measurements were done. In conclusion, the extensogram peak height gave very high and statistically significant correlation coefficient with the Alvetron values at 0.01 level, as being r= 0.810xx (for 1st day), r= 0.828xx (for 2nd day) r= 0.872xx (for 3rd day). Thus, it is understood that the extensograph is a very useful instrument in the measurement of bread crumb firmness as a parameter of the staleness of bread crumb.

Özet

-

🔖

Cite This Article

Anonim (1986). The Possibility of the Use of Bread Crumb Firmness Obtained on Extensograph as a Parameter in the Estimation of Staleness of Bread Crumb (Turkish with English Abstract). Gıda, Cilt: 11 - Sayı: 5. https://ajindex.com/articles/127382

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...