Journals / Turkish Journal of Veterinary and Animal Sciences / 2008 / Cilt: 32 - Sayı: 5

Ultrasonographic Examination of the Goat Liver

Pages
385–388
Publication Date
2008-05-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Ultrasonographic measurement of liver size and location in healthy goats can be used as a reference for changes in the liver attributable to illness.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The purpose of this study was to obtain detailed information about the normal size and texture of the goat liver by means of ultrasonographic examination.
📊
Key Findings & Data:The structure, location, and size of the liver, portal vein, and caudal vena cava were examined ultrasonographically in 6 goats.
💡
Conclusion & Impact:Ultrasonographic measurement of liver size and location in healthy goats can be used as a reference for changes in the liver attributable to illness.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Ultrasonography · liver · goat

Abstract

The purpose of this study was to obtain detailed information about the normal size and texture of the goat liver by means of ultrasonographic examination. The structure, location, and size of the liver, portal vein, and caudal vena cava were examined ultrasonographically in 6 goats. The angle of the liver and the thickness of the gallbladder wall were also determined. Examinations were performed on the right side of the abdomen, from the 6th through 12th intercostal space, using a 6-13 MHz linear transducer. In each intercostal space the dimensions of the liver, and if visible, the location and diameter of the portal vein and caudal vena cava were determined. Ultrasonographic measurement of liver size and location in healthy goats can be used as a reference for changes in the liver attributable to illness.

Özet

The purpose of this study was to obtain detailed information about the normal size and texture of the goat liver by means of ultrasonographic examination. The structure, location, and size of the liver, portal vein, and caudal vena cava were examined ultrasonographically in 6 goats. The angle of the liver and the thickness of the gallbladder wall were also determined. Examinations were performed on the right side of the abdomen, from the 6th through 12th intercostal space, using a 6-13 MHz linear transducer. In each intercostal space the dimensions of the liver, and if visible, the location and diameter of the portal vein and caudal vena cava were determined. Ultrasonographic measurement of liver size and location in healthy goats can be used as a reference for changes in the liver attributable to illness.

🔖

Cite This Article

SOROORI, S., RAOOFI, A., VAJHI, A. R., NEZAMI, S. G. (2008). Ultrasonographic Examination of the Goat Liver. Turkish Journal of Veterinary and Animal Sciences, Cilt: 32 - Sayı: 5, 385–388. https://ajindex.com/articles/122335

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...