Journals / Turkish Journal of Veterinary and Animal Sciences / 2011 / Cilt: 35 - Sayı: 3

Comparison of placentome diameters in single and twin-pregnant sheep by ultrasonographic method

Pages
187–191
Publication Date
2011-03-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The results showed no significant difference between placentome diameter size in single and twin-pregnant ewes except during the 5th and 12th weeks.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of this study was to determine the correlation between fetal number and placentome diameters in pregnant sheep.
📊
Key Findings & Data:In the present study 25 Kıvırcık mixed breed pregnant ewes were used.
💡
Conclusion & Impact:The results showed no significant difference between placentome diameter size in single and twin-pregnant ewes except during the 5th and 12th weeks.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Key words: Pregnant ewe · fetal number · placentome diameter

Abstract

The aim of this study was to determine the correlation between fetal number and placentome diameters in pregnant sheep. In the present study 25 Kıvırcık mixed breed pregnant ewes were used. Pregnancy of the ewes was diagnosed by transrectal ultrasonography by the 25th day after insemination. A transabdominal probe (6.5 MHz) was used on the pregnant ewes at the 30th day. At this time the placentomes appeared as hypoechogenic areas with a "C"-like shape. Throughout the pregnancies 5 placentomes were measured from each ewe every week. The results showed no significant difference between placentome diameter size in single and twin-pregnant ewes except during the 5th and 12th weeks. The average of placentome diameter size in the single and twin-pregnant ewes was, respectively, 6.60 ± 0.56 mm and 8.20 ± 0.45 mm at the 5th week and 34.02 ± 1.62 mm and 29.47 ± 0.63 mm at the 12th week. The minimum significance degree was P < 0.05 in statistical analysis. This study found that measurement of placentome diameter size at the 5th and 12th week of pregnancy is not helpful in determining fetal number in a pregnant ewe. However, further investigations are needed to explain the difference in placentome diameter at the 5th and 12th weeks of pregnancy.

Özet

The aim of this study was to determine the correlation between fetal number and placentome diameters in pregnant sheep. In the present study 25 Kıvırcık mixed breed pregnant ewes were used. Pregnancy of the ewes was diagnosed by transrectal ultrasonography by the 25th day after insemination. A transabdominal probe (6.5 MHz) was used on the pregnant ewes at the 30th day. At this time the placentomes appeared as hypoechogenic areas with a "C"-like shape. Throughout the pregnancies 5 placentomes were measured from each ewe every week. The results showed no significant difference between placentome diameter size in single and twin-pregnant ewes except during the 5th and 12th weeks. The average of placentome diameter size in the single and twin-pregnant ewes was, respectively, 6.60 ± 0.56 mm and 8.20 ± 0.45 mm at the 5th week and 34.02 ± 1.62 mm and 29.47 ± 0.63 mm at the 12th week. The minimum significance degree was P < 0.05 in statistical analysis. This study found that measurement of placentome diameter size at the 5th and 12th week of pregnancy is not helpful in determining fetal number in a pregnant ewe. However, further investigations are needed to explain the difference in placentome diameter at the 5th and 12th weeks of pregnancy.

🔖

Cite This Article

KAŞIKÇI, G., YILMAZ, Ö. T., GÜNDÜZ, M. C., KIRŞAN, İ. (2011). Comparison of placentome diameters in single and twin-pregnant sheep by ultrasonographic method. Turkish Journal of Veterinary and Animal Sciences, Cilt: 35 - Sayı: 3, 187–191. https://ajindex.com/articles/122086

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Doizé, F., Vaillancourt, D., Carabin, H., Bélanger, D.: Determination of gestational age in sheep and goats using transrectal ultrasonographic measurement of placentomes. Th eriogenology, 1997; 48: 449-460.
  2. Kelly, R.W., Newnham, J.P.: Estimation of gestational age in Merino ewe by ultrasound measurement of fetal head size. Aust. J. Agri. Res., 1989; 40: 1293-1299.
  3. Küplülü, Ş., Çetin, Y., Macun, H.C., Taşdemir, U.: Estimation of early diagnostic range by transrectal and transabdominal ultrasonographic method in Akkaraman ewes. Lalahan Hay. Araşt. Enst. Dergisi, 2002; 42: 25-33.
  4. Schrick, F.M., Inskeep, E.K.: Determination of early pregnancy in ewes utilizing transrectal ultrasonography. Th eriogenology, 1993; 40: 295-306.
  5. West, D.M.: Pregnancy diagnose in the ewe. In: Morrow, D.A., Ed. Current Th erapy in Th eriogenology. 2nd edn, W.B. Saunders Co., Philadelphia. 1986; 850-852.
  6. Rawlings, N.C., Jeff coate, I.A., Savage, N.C., Steuart, D.M.K., Steuart, L.H.M.: Pregnancy diagnosis and assessment of fetal numbers in the ewe in a commercial setting. Th eriogenology, 1983; 19: 655-663.
  7. Trapp, M.J., Slyter, A.L.: Pregnancy diagnosis in the ewe. J. Anim. Sci., 1983; 57: 1-5.
  8. Schneider, F.A., Hallford, D.M.: Use of a rapid progesterone radioimmunoassay to predict pregnancy and fetal numbers in ewes. Sheep and Goat Res. J. 1996; 12: 33-38. 9. Illera, J.C., Gracia, O., Silvan, G., Illera, M.J., Munro, C.J., Illera, M.: Assessment of fetal number and fetal viability throughout pregnancy in Manchega ewe. 14th Inter. Cong. Anim. Reprod., Stockholm, 2000; 2: 181. Kalkan, C., Cetin, H., Kaygusuzoglu, E., Yılmaz, B., Cift ci, M., Yıldız, H., Yıldız, A., Deveci, H., Apaydın, A.M., Ocal, H.: An investigation on plasma progesterone levels during pregnancy and parturition in the Ivesi sheep. Acta Vet. Hung. 1996; 44 335-340.
  9. Grace, N.D., Beach, A.D., Quinlivan, T.D., Ward, B.: Multiple pregnancy diagnosis of using real time ultrasonic body scanner and video-fl ouroscopy systems. Proc. N. Z. Soc. Anim. Prod., 1989; 49:107-111.
  10. Fukui, Y., Kobayashi, M., Tsubaki, M., Shimoda, K., Ono, H.: Comparison of two ultrasonographic methods for multiple pregnancy diagnosis in sheep and indicators of multiple pregnant ewes in the blood. Anim. Reprod. Sci., 1986; 11: 25- 33. Reynolds, L.P., Redmer, D.A.: Utero-placental vascular development and placental function. J. Anim. Sci., 1995; 73: 1839-1851.
  11. Menzies, P.I., Bailey, D.: Diseases of the periparturient ewe. In: Youngquist, R.S. Ed. Current